PCV Series
• Proportional controller • Ratings from 15A to 90A @ 240 VAC • 2-7 V DC or 2-10 V DC analo g input range
PRODUCT SELECTION Description
2-7 VDC Control 2-10 VDC Control
15 A
7PCV2415 10PCV2415
25 A
7PCV2425 10PCV2425
50 A
10PCV2450
75 A
10PCV2475
90 A
10PCV2490
OUTPUT SPECIFICATIONS (1) Description
Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) Maximum Load Current (3) [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum I² t for Fusing (8.3 msec) [A² sec] Minimum Power Factor (with Maximum Load) 100-240 600 10 200 15 0.15 150 1.6 94 0.5 100-240 600 10 200 25 0.15 250 1.6 260 0.5 100-240 600 10 200 50 0.15 625 1.6 1620 0.5 100-240 600 10 200 75 0.15 1000 1.6 4150 0.5 100-240 600 10 200 90 0.15 1200 1.6 6000 0.5
INPUT SPECIFICATIONS (1) Description
Control Voltage Range Typical Input Current @ 5 VDC 2-7 VDC 4 mA 2-10 VDC 4 mA
GENERAL SPECIFICATIONS Description
Dielectric Strength, Signal to Load (50/60Hz) Dielectric Strength, Signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals
Parameters
2500 Vrms 2500 Vrms -30 to 80 °C -40 to 125 °C 3.5 oz. (100g) Themaly Conductive Epoxy Screws and Saddle clamps Furnished, Unmounted
GENERAL NOTES
1) All param eters at 25°C unless otherwise specified.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
TYPICAL APPLICATIONS
• Industrial temperature controllers • Light dimming • Vibratory feeders • Resistive heating elements • Rectified DC motors • Conveyor speed control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications Including, but not limited to the following: • AC motor control • Three Phase motors • Transformers requiring pure sine wave input • Zero crossing applications Please contact Crydom’s application Engineering department for additional Information and specific application questions.
AGENCY APPROVALS
Rev. 121108
ANNEX - ENVIROMENTAL INFORMATION