LC Series
• Mini-SIP SSR • Ratings to 2A @ 280 VAC • Triac output • DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) output • Plastic encapsulated
PRODUCT SELECTION
Control Voltage
4-10 VDC
1.5A
LC241
2A
LC242
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum Load Current [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Minimum Power Factor (with Maximum Load) 12-280 600 0.1 500 1.5 0.025 80 1.5 0.5 12-280 600 0.1 500 2.0 0.025 100 1.5 0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range Must Turn On Voltage Must Turn Off Voltage Typycal Input Current @ 5 VDC Nominal Input Impedance Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] 4-10 VDC 4.0 VDC 1.0 VDC 15 mAdc 300 Ohm 1/2 Cycle 1/2 Cycle
For Contact information visit our web site.
www.crydom.com
©2008 Crydom, Inc. Specifications subject to change without notice.
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2) Minimum Insulation Resistance (@ 500 VDC)(2) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation
Parameters
2500 Vrms
109 Ohm
8 pF -40 to 80˚C -40 to 125˚C 0.15 oz. (4.3g) UL94V-0Molded epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified. 2) Dielectric and insulation resistence are measured between input and output. 3) Off-State dv/dt test method per EIA/NARM standard RS-443. 4) 0.1 msec for random turn-on version (R suffix).
MECHANICAL SPECIFICATIONS
DC C ONTROL PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: -DC CONTROL
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL / cUL E116950 Rev. 061608
For Contact information visit our web site.
www.crydom.com
©2008 Crydom, Inc. Specifications subject to change without notice.
For Contact information visit our web site.
www.crydom.com
©2008 Crydom, Inc. Specifications subject to change without notice.
ANNEX - ENVIROMENTAL INFORMATION