RPC Series
• Proportional controller • Ratings from 15A to 40A @ 480 VAC • 500k or 1M Ohm potentiometer control
PRODUCT SELECTION Description
120 VAC 240 VAC 480 VAC
15 A
RPC1215 RPC2415 RPC4815
25 A
RPC1225 RPC2425 RPC4825
40 A
RPC1240 RPC2440 RPC4840
OUTPUT SPECIFICATIONS (voltage) (1) Description
Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) Snubber (Internal)
120 VAC
90-130 400 10 5000 yes
240 VAC
200-240 600 7 500 yes
480 VAC
400-480 1200 3 500 no
OUTPUT SPECIFICATIONS (current) (1) Description
Maximum Load Current [Arms] (3) Minimum Load Current [mArms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum I²t for Fusing (8.3 msec) [A² sec]
15 A
15 70 150 1.6 1.48 94
25 A
25 80 250 1.6 1.02 260
40 A
40 90 625 1.6 0.63 1620
INPUT SPECIFICATIONS (1) Description
Variable Resistor Size (4)
120 VAC
150K (1W)
240 VAC
1M (1/2W)
480 VAC
1M (1/2W)
GENERAL SPECIFICATIONS Description
Minimum Power Factor (with Maximum Load) Dielectric Strength, Input/Output/Base (50/60Hz) Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals Recommended Terminal Screw Torque Range: 0.6 2500 Vrms -30 to 80 °C -40 to 125 °C 3.2 oz (90g) Thermally conductive Epoxy Screws and saddle Clamps Furnished, Unmounted 6-32 Screws -10 in lbs. 8-32 and 10-32 Screws -20 in. lbs. (Screws dry without grase)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443 3) Heat sinking required, see derating curves. 4) Potentiometer should be line voltage rated.
F or Contact information visit our web site.
www.crydom.com
© 2008 Crydom, Inc. Specifications subject to change without notice.
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
PERCENTAGE ON VS INPUT RESISTANCE
AGENCY APPROVALS
Rev. 102408
F or Contact information visit our web site.
www.crydom.com
© 2008 Crydom, Inc. Specifications subject to change without notice.
F or Contact information visit our web site.
www.crydom.com
© 2008 Crydom, Inc. Specifications subject to change without notice.
ANNEX - ENVIROMENTAL INFORMATION
For Contact information visit our web site.
www.crydom.com
© 2008 Crydom, Inc. Specifications subject to change without notice.