Powered by
HRL 1210W
6
12V 10W
Specification
Cells per unit Voltage per unit Capacity Weight Maximum Discharge Current Internal Resistance Operating Temperature Range
HRL 1210W is specially designed for high efficient discharge application. Its characteristics are high energy density, small footprint and high discharge efficiency. It can be used for more than 260 cycles at 100% discharge in cycle service, up to 8 years in standby service.
12 o o 10W @ 15min-rate to 1.67V per cell @25 C(77 F)
2.5Ah @ 20hr-rate to 1.75V per cell @25
Approx.1.1 kg(2.43 lbs) 40A(5sec) Approx. 35m Discharge: -15 ~50 ( 5 ~122 ) Charge: -15 ~40 ( 5 ~104 ) Storage: -15 ~40 ( 5 ~104 ) 25 C±3 C (77 F±5 F)
o o o o
(77
)
Nominal Operating Temperature Range Float Charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Self Discharge
13.5 to 13.8 VDC/unit Average at 25
1A
(77 )
14.4 to 15.0 VDC/unit Average at 25
o o
(77
)
CSB Batteries can be stored for more than 6 months at 25 C (77 F). Please charge batteries before using. For higher temperatures the time interval will be shorter.
CSB-manufactured VRLA batteries are ULrecognized components under UL924 and UL1989. CSB is also certified by ISO 9001 and ISO 14001.
Terminal Container Material
F2-Faston Tab 250 ABS(UL 94-HB/File E50263)*Flammability resistance of (UL 94-V0/File E88637) can be available upon request.
Dimensions :
Unit: mm (inch)
Overall Height (H) 70±1 (2.76±0.04)
178±2(7.01±0.08)
Container height (h) 64±1 (2.52±0.04)
Length (L) 178±2 (7.01±0.08)
Width (W) 34±1 (1.34±0.04)
A
34±1(1.34±0.04)
6.35(0.25)
64±1(2.52±0.04)
70±1(2.76±0.04)
3.4(0.13) 7.95(0.31)
7.75(0.30)
177.6(6.99)
3.15 (0.12)
11.6 11 (0.45) (0.43)
0.8(0.03)
33.6(1.32)
Constant Current Discharge Characteristics
Unit:A (25
,77
)
F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
2MIN 19.2 18.3 17.9 17.1 16.3 15.6
2MIN 200 193 189 182 175 169
4MIN 13.7 13.3 13.0 12.5 11.8 11.1
4MIN 147 143 140 134 128 121
6MIN 10.5 10.2 10.1 9.85 9.50 9.15
6MIN 113 110 108 106 103 100
8MIN 8.84 8.70 8.64 8.37 8.10 7.83
8MIN 95.6 94.0 92.9 91.0 89.1 86.6
10MIN 7.47 7.37 7.32 7.15 6.98 6.81
10MIN 81.5 80.5 79.8 78.9 77.3 75.8
15MIN 5.51 5.43 5.39 5.27 5.14 5.02
15MIN 60.9 60.0 59.3 58.5 57.2 55.8
20MIN 4.24 4.20 4.18 4.10 4.02 3.94
20MIN 47.0 46.5 46.3 46.0 45.2 44.5
30MIN 3.06 3.03 3.02 2.98 2.93 2.89
30MIN 34.1 34.0 33.9 33.5 33.0 32.6
60MIN 1.66 1.64 1.63 1.62 1.60 1.59
)
90MIN 1.29 1.28 1.27 1.26 1.25 1.24
90MIN 14.7 14.6 14.5 14.4 14.3 14.2
Constant Power Discharge Characteristics
Unit:W (25
,77
60MIN 18.7 18.6 18.5 18.4 18.2 18.1
RA0812
HRL 1210W
12V 10W
140 120 100 80 60 40 20
0.049 0.042 0.035 0.028 0.021 0.014 0.007
2.60 2.40 2.20 2.00 1.80 1.60 1.40 1PWx15Min 1PWx7.5Min
)Ratio
0.025PA
0
3
6
9
12
15
18
140 120 100 80 60 40 20
0.049 0.042 0.035 0.028 0.021 0.014 0.007
2.60 2.40
68
2.20 2.00 1.80 1.60 14.70V 1.40 2.45V 0.025PA 1PWx15Min 1PWx7.5Min
)Ratio
0
3
6
9
12
15
18
Charging Procedures
Application Cycle Use Standby Charge Voltage(V/Cell) Temperature 25 (77 ) 25 (77 ) Set Point 2.45 2.275 Allowable Range 2.40~2.50 2.25~2.30 Max.Charge Current 0.1PA
Final Discharge Voltage V/Cell Discharge Power(W)
1.75 0.1P>(W)
1.70 0.1P (W)
很抱歉,暂时无法提供与“HRL1210W”相匹配的价格&库存,您可以联系我们找货
免费人工找货