SERIES: CBM-50V | DESCRIPTION: DC BLOWER
• omniCOOLTM bearing system
• multiple speed options for different cooling needs
• 50 x 50 mm frame
• auto restart protection standard on all models
MODEL
input
voltage
rated
(Vdc)
N
UE
D
FEATURES
input
current1
input
power1
rated
speed1
air
flow2
static pressure3
noise4
range
(Vdc)
max
(mA)
max
(W)
typ
(RPM±15%)
(CFM)
(inch H2O)
max
(dBA)
12
6~13.8
40
0.48
3000
2.6
0.18
23.4
CBM-5015V-140
12
4.5~13.8
65
0.78
4000
3.5
0.40
33.1
TI
CBM-5015V-130
12
4.5~13.8
115
1.38
5000
4.5
0.67
39.8
12
4.5~13.8
196
2.36
6000
5.4
0.97
42.2
CBM-5020V-144*
12
6~13.8
88
1.1
4400
5
4.8
0.46
30.0
CBM-5020V-148*
12
6~13.8
104
1.3
48005
5.2
0.56
33.0
12
6~13.8
124
1.5
5200
5.7
0.66
35.0
CBM-5020V-152*
1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
5. Typical rated speed is measured as RPM±10% at rated voltage.
6. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
*. Discontinued model.
DI
SC
Notes:
ON
CBM-5015V-150*
CBM-5015V-160
cuidevices.com
5
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 2 of 7
INPUT
parameter
conditions/description
operating input voltage1
min
typ
max
units
4.5
12
13.8
Vdc
4.5
starting voltage
2
Vdc
1. See Model section on page 1 for specific input voltage ranges.
2. Starting voltage for models CBM-5015V-130, CBM-5020V-144, CBM-5020V-148, and CBM-5020V-152 is 6 Vdc.
PERFORMANCE3
parameter
conditions/description
N
UE
D
Note:
min
typ
max
units
rated speed
at rated voltage, 25°C, after 10 minutes
3000
6000
RPM
air flow
at 0 inch H2O, see performance curves
2.6
5.7
CFM
static pressure
at 0 CFM, see performance curves
0.18
0.97
inch H2O
noise
at 1 m
23.4
42.2
dBA
typ
max
units
typ
max
units
Note:
3. See Model section on page 1 for specific values.
PROTECTIONS
conditions/description
auto restart
when the fan motor is locked by an external force, the device will temporarily turn off electrical power to the motor
and restart automatically when the locked rotor condition
is released
SAFETY & COMPLIANCE
parameter
min
TI
parameter
conditions/description
min
at 500 Vdc between internal stator and positive lead wire
dielectric strength
apply 500 Vac for 1 minute between housing and positive
lead wire
safety approvals
UL/cUL 507, TUV (EN 60950-1)
EMI/EMC
life expectancy
RoHS
ON
insulation resistance of frame
10
MΩ
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
at 40°C, 65% RH
70,000
hours
yes
ENVIRONMENTAL
parameter
operating temperature
DI
SC
storage temperature
conditions/description
cuidevices.com
min
max
units
-10
typ
70
°C
-40
70
°C
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 3 of 7
PERFORMANCE CURVES
0.08
5
4
0.16
2
3
0.12
0.08
2
0.04
1
0.5
1
1.5
2
2.5
Air Flow (CFM)
0.02
0.04
0.8
Air Flow (CMM)
0.06
0.08
0.1
0.12
0.2
4
0.1
0
0.5
0
10
0.2
DI
1
2
3
Air Flow (CFM)
4
5
5
1
1.5
2
2.5
Air Flow (CFM)
3
3.5
cuidevices.com
Air Flow (CMM)
1
0.16
25
0.8
20
0.6
15
0.4
10
0.2
5
0
0
0.04
0.08
0.12
2
Static Pressure (inch H O)
0.4
2
Static Pressure (mm H O)
15
0
2
0.14
SC
2
6
20
0.6
0
8
0
CBM-5015V-160
ON
0
10
0.3
0
0
0.1
2
CBM-5015V-150
3
0.08
Static Pressure (mm H O)
0
Air Flow (CMM)
0.04
0.06
0.02
TI
0
Static Pressure (inch H O)
0.4
0
2
0.06
N
UE
D
0.04
2
Air Flow (CMM)
Static Pressure (inch H O)
0.02
Static Pressure (mm H O)
0
2
Static Pressure (inch H O)
0.2
CBM-5015V-140
Static Pressure (mm H O)
CBM-5015V-130
0
1
2
3
4
Air Flow (CFM)
5
6
0
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 4 of 7
PERFORMANCE CURVES (CONTINUED)
20
0.5
10
0
0
5
10
0
0.14
0.28
CMM
ON
inch H O
2
mm H O
2
CBM-5020V-152
1.0
20
0.5
SC
Static Pressure
CFM
10
0
5
10
0
0.14
0.28
DI
0
Air Flow
30
1.0
20
0.5
10
0
0
5
10
0
0.14
0.28
TI
Air Flow
30
N
UE
D
1.0
inch H O
2
mm H O
2
inch H O
2
30
CBM-5020V-148
Static Pressure
Static Pressure
mm H O
2
CBM-5020V-144
CFM
CMM
cuidevices.com
Air Flow
CFM
CMM
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 5 of 7
MECHANICAL
conditions/description
motor
CBM-5015V models: 4 pole DC brushless
CBM-5020V models: 8 pole DC brushless
bearing system
omniCOOL™
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CBM-5015V models: 51.7 x 51.6 x 15
CBM-5020V models: 50 x 50 x 20
material
PBT (UL94V-0)
weight
CBM-5015V models
CBM-5020V models
MECHANICAL DRAWINGS
units: mm
wire: UL 1061, 26 AWG
CBM-5015V
Red
+Vin
Black
-Vin
ON
Function
SC
CBM-5020V
WIRE CONNECTIONS
Function
Red
+Vin
Black
-Vin
DI
Wire Color
typ
max
units
mm
mm
30
33
TI
WIRE CONNECTIONS
Wire Color
min
N
UE
D
parameter
cuidevices.com
g
g
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 6 of 7
SAFETY CONSIDERATIONS
1.
Do not use or operate this fan in excess of the limitations set forth in this specification. CUI is not responsible for the non-performance
of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications.
N
UE
D
2. CUI recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or
current fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in
cases of motor lead short circuit, overload, or over voltage, and/or other failure.
3. CUI recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of
reverse connection between Vdc (+) and GND (-). The failue to install such a device may result in smoke, fire, and/or destruction,
although these conditions may not manifest immediately.
4. This fan mush be installed and used in compliance with all applicable safety standards and regulations.
5. Use proper care when handling and/or installing this fan. Improper handling of installation of this fan may cause damage that could
result in unsafe conditions.
6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan
including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
TI
7. Do not use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact CUI to customize the
product design for your application.
8. For critical or extreme environments, including non-stop operation, please contact CUI and we will gladly provide assistance with your
product selection to ensure an appropriate cooling product for your application.
ON
9. When building your device, please examine thouroughly any variation of EMC, temperature rise, life data, quality, etc. of this product
by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually
discussed and examined.
10. Use proper care when handling these fans. Components such as fan holders or bearings may be damaged, if touched with fingers or
other objects. Additionally, static electricity (ESD) may damage internal circuits of the fan.
11. Do not operate these fans in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas
environments including, but not limited to, H2S, SO2, NO2, or Cl2.
SC
12. CUI recommends that you protect these fans from exposure to outside elements such as dust, condensation, humidity, or insects.
Exposure of this fan to such elements may affect its performance and my cause safety hazards. CUI does not warrant against damage
to the product caused by outside elements.
13. The fans must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise.
14. Do not store these fans in an environment with high humidity. These fans must be stored in accordance with the specified storage
temperature.
DI
15. CUI reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not
affect the specifications as described herein.
16. The life expectancy of these fans has not been evaluated for use in combination with any end application. Therefore, the life
expectancy that relate to these fans are only for reference.
cuidevices.com
Additional Resources:
Product Page
CUI DEVICES | SERIES: CBM-50V | DESCRIPTION: DC BLOWER
date 08/12/2022 | page 7 of 7
REVISION HISTORY
rev.
description
date
initial release
08/02/2017
brand update
02/07/2020
1.02
discontinued model CBM-5020V-144
01/13/2021
1.03
discontinued models CBM-5020V-148 and CBM-5020V-152
06/07/2021
1.04
discontinued model CBM-5015V-150
11/22/2021
logo, datasheet style update
08/12/2022
N
UE
D
1.0
1.01
1.05
DI
SC
ON
TI
The revision history provided is for informational purposes only and is believed to be accurate.
CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate
and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may
result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A
critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
cuidevices.com