Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
07/13/2022
page
1 of 12
SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
up to 700 W isolated output
industry standard full brick package
2:1 input range (18~36 Vdc, 36~75 Vdc)
single output from 12~48 Vdc
1,500 Vdc isolation
over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• efficiency up to 92%
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VFB600-D24-S12
24
18~36
12
50
600
120
88
VFB600-D24-S24
24
18~36
24
25
600
240
90
VFB600-D24-S28
24
18~36
28
21.5
600
280
90
VFB600-D24-S32
24
18~36
32
19
600
320
91
VFB600-D24-S48
24
18~36
48
12.5
600
480
91
VFB600-D48-S12
48
36~75
12
50
600
120
90
VFB600-D48-S24
48
36~75
24
25
600
240
92
VFB600-D48-S28
48
36~75
28
25
700
280
91
VFB600-D48-S32
48
36~75
32
19
600
320
92
VFB600-D48-S48
48
36~75
48
12.5
600
480
92
Notes:
1. Ripple and noise measured at full load, 20 MHz BW with 10 μF tantalum and 1 μF ceramic capacitor across the output.
2. An external input capacitor of 220 μF is recommended to reduce input ripple voltage.
3. All specifications measured at nominal line, full load, and 25°C unless otherwise specified.
PART NUMBER KEY
VFB600 - DXX - SXX X
Base Number
Input Voltage
cui.com
Output Voltage
Remote On/Off Control
"blank" = negative logic
P = positive logic
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 2 of 12
INPUT
parameter
conditions/description
operating input voltage
24 Vdc input models
48 Vdc input models
min
typ
max
units
18
36
24
48
36
75
Vdc
Vdc
24 Vdc input
power up
power down
17
16
Vdc
Vdc
48 Vdc input
power up
power down
35
33
Vdc
Vdc
24 Vdc input
power up
power down
38
40
Vdc
Vdc
48 Vdc input
power up
power down
77
80
Vdc
Vdc
under voltage shutdown
over voltage shutdown
start-up time
positive logic
on/off
1
negative logic
ms
models OFF (1.0~10 mA)
models ON (1.0~10 mA)
models OFF (0~0.01 mA)
filter
pi filter
input fuse
60 A time delay fuse for 24 Vin models,
30 A time delay fuse for 48 Vin models
Note:
250
models ON (0~0.01 mA)
1. See application notes.
OUTPUT
parameter
conditions/description
min
output capacitance2
12 Vdc output models
all other models
470
470
line regulation2
load regulation
2
typ
max
units
10,000
5,000
μF
μF
from low line to high line
±0.2
%
from full load to no load
±0.5
%
±1.5
%
voltage accuracy2
load share accuracy
from 50~100% load
±10
adjustability
60
switching frequency
48 Vdc input: 12 Vdc, 28 Vdc, 32 Vdc models
all other models
transient response
25% load step change
300
250
temperature coefficient
power good (IOC)
Vout ready: low level, sink current
Vout not ready: open drain output, applied voltage
auxiliary output voltage/current
10 ±3 Vdc, 20 mA max.
Note:
%
110
%
kHz
kHz
500
μs
±0.03
%/°C
20
50
mA
V
max
units
150
%
2. Minimum capacitor values are required on the output to maintain the specified regulation.
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous
min
over current protection
110
over voltage protection
over temperature protection
typ
115
shutdown
140
110
cui.com
%
°C
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 3 of 12
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute, input to output, input to case, or
output to case
min
isolation resistance
UL 60950-1
MTBF
as per MIL-HDBK-217F at full load, GB, 25 °C
RoHS
2011/65/EU (CE)
max
units
1,500
Vdc
10
MΩ
isolation capacitance
safety approvals
typ
4,000
pF
450,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating case temperature
see derating curve
storage temperature
humidity
typ
max
units
-40
100
°C
-55
105
°C
95
%
max
units
260
°C
max
units
non-condensing
SOLDERABILITY
parameter
conditions/description
wave soldering
see wave soldering profile
Notes:
1.
2.
3.
4.
5.
min
typ
Soldering materials: Sn/Cu/Ni
Ramp up rate during preheat: 1.4°C/s (from 50°C to 100°C)
Soaking temperature: 0.5°C/s (from 100°C to 130°C), 60±20 seconds
Peak temperature: 260°C, above 250°C for 3~6 seconds
Ramp down rate during cooling: -10°C/s (from 260°C to 150°C)
MECHANICAL
parameter
conditions/description
min
dimensions
116.8 x 61.0 x 12.7(4.60 x 2.40 x 0.50 inch)
case material
aluminum baseplate with plastic case
weight
typ
mm
220
cui.com
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 4 of 12
MECHANICAL DRAWING
units: mm[inch]
tolerance: X.X = ±0.5[±0.02]
X.XX = ±0.25[±0.010]
pin diameter tolerance: ±0.1[±0.004]
104.11 4.099
100.30 3.949
96.49 3.799
92.68 3.649
88.87 3.499
+Vin
3
-ON/OFF
4
+ON/OFF
5
+Vo
6
+Vo
7
+Vo
8
-Vo
9
-Vo
10
-Vo
11
-S
12
+S
13
TRIM
14
PC/NC
15
IOC
16
AUX
2.06 0.081
(8 PLCS)
43.20 1.701
10
1
8
7
3
4
6
22.88 0.901
5
19.07 0.751
5.05 0.199
57.17 2.251
9
2
33.04 1.301
12
11
-Vin
2
13
1
14
Function
1.02 0.040
(8 PLCS)
85.06 3.349
16
Pin
3.50 0.138
THROUGH HOLE
(4 PLCS)
15
PIN CONNECTIONS
106.70 4.201
7.20 0.283
(TYP)
12.70 0.500
116.80 4.598
2.4mm P LAT E D T HR OUG H HOLE
4.8mm P AD S IZE
3.5mm NON T HR OUG H HOLE
1.4mm P LAT E D T HR OUG H HOLE
2.8mm P AD S IZE
PCB Layout
Top View
cui.com
10.16 0.400
35.56 1.400
61.00 2.402
22.86 0.900
50.80 2.000
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 07/13/2022 │ page 5 of 12
DERATING CURVES
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 07/13/2022 │ page 6 of 12
DERATING CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 07/13/2022 │ page 7 of 12
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 07/13/2022 │ page 8 of 12
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 07/13/2022 │ page 9 of 12
APPLICATION NOTES
1. Parallel Operation
The VFB600 series is designed for parallel operation. When in parallel the load current can be shared equally between the two
modules by connecting their PC pins. The VFB600 can be setup in two different modes to achieve parallel operation. The standard
parallel operation is suitable when load cannot be handled by a single unit, whereas the N+1 redundant operation is suitable for loads
when backup power is required.
Figure 1
Standard Parallel Connection
Figure 2
Parallel Connection With Programmed And Adjustable Output
Figure 3
N+1 Redundant Connection
Figure 4
N+1 Redundant Connection With Programmed Output And Adjustable
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 10 of 12
APPLICATION NOTES (CONTINUED)
2.
Output Voltage Trimming
Leave open if not used.
Figure 5
External Resistors
Trim-Up/Trim-Down Formulas
1.24 ×(
Vf =
7.68 +(
Rt ×33
)
Rt + 33
Rt ×33
)
Rt + 33
Vout = (Vo + VR) × Vf
Note: Rt = 6.8 kΩ
VO is the nominal output voltage
VOUT is the desired output voltage (up or down)
VR is the trim resistor in kΩ
Figure 6
External DC Voltage
Trim-Up/Trim-Down Formula
Vout = VT × VO
Note: VT is the trim terminal voltage
VO is the nominal output voltage
VOUT is the desired output voltage (up or down)
3.
ON/OFF Control
The converter's ON/OFF function can be controlled from the input side or from the output side. The maximum current through the
ON/OFF pin is 10 mA. The resistor value has to be set appropriately to avoid the maximum current through the ON/OFF pins. The
remote on/off control has to be connected for the converter to operate.
(A)
Controlling the ON/OFF terminal from the input side.
Recommended R1 value is 30 kΩ (0.5 W) for 48VIN and
15 kΩ (0.25 W) for 24VIN
(B)
Figure 7
Controlling the ON/OFF terminal from the output
side. Recommended R2 value is 5.1 kΩ (0.1 W)
Figure 8
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 11 of 12
APPLICATION NOTES (CONTINUED)
4.
IOC Signal
Normal and abnormal operation of the converter can be monitored by using the I.O.C signal. Output of this signal monitor is located
at the secondary side and is open collector output, you can use the signal by the internal aux power supply or the the external DC
supply as the following figures. the ground reference is the –Sense. This signal is LOW when the converter is normally operating and
HIGH when the converter is disabled or when the converter is abnormally operating.
Figure 9
Internal AUX Power
Figure 10
External DC Power
5. Output Remote Sensing
This series has the capability to remotely sense both lines of its output. This feature moves the effective output voltage regulation
point from the output of the unit to the point of connection of the remote sense pins. This feature automatically adjusts the real
output voltage in order to compensate for voltage drops in distribution and maintain a regulated voltage at the point of load. The
voltage range of this is:
[(+Vout) – (-Vout)] – [(+Sense) – (-Sense)] ≤ 10% of the Vout nominal.
If the sense feature is not used, the sense pins should be connected locally to the respective Vout pins. Please note that although the
output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the
sum of both.
Figure 11
6.
Test Configuration
Figure 12
Table 1
Recommended External components
cui.com
C1
220 μF/100 V
C2
470 μF/100 V
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VFB600 │ DESCRIPTION: DC-DC CONVERTER
date 07/13/2022 │ page 12 of 12
REVISION HISTORY
rev.
description
date
1.0
initial release
06/27/2011
1.02
adjustability note added, V-Infinity branding removed
08/07/2012
1.03
updated spec
04/01/2013
1.04
added UL approvals to 24 Vdc and 48 Vdc output models
03/05/2014
1.05
added application note information
04/10/2017
1.06
product image and company logo updated
02/15/2021
1.07
derating curves, efficiency curves and circuit figures updated
09/14/2021
PN key updated
07/13/2022
1.08
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“VFB600-D48-S24”相匹配的价格&库存,您可以联系我们找货