Additional Resources:
Product Page
date
07/10/2018
page
1 of 4
ED
SERIES: VGD-60 Ϳ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
up to 60 W continuous power
universal input (85~264 Vac / 120~370 Vdc)
dual output
overload, over voltage, and short circuit protections
UL/cUL and Intertek 60950-1 safety approvals
EXLOWLQ(0,¿OWHU
efficiency up to 80%
output
voltage
(Vdc)
VGD-60-D512
5
12
VGD-60-D524
5
24
output
power1
ripple
and noise2
HϒFLHQF\
min
(A)
max
(A)
max
(W)
max
(mVp-p)
W\S
(%)
0.3
0.3
6
4
60
80
120
79
0.3
0.3
6
2.2
60
80
240
80
N
1. Maximum total combined power.
2. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
IS
C
O
Notes:
output
current
TI
MODEL
N
U
•
•
•
•
•
•
•
D
PART NUMBER KEY
VGD-60 - DXXX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: VGD-60 Ϳ DESCRIPTION: AC-DC POWER SUPPLY
date 07/10/2018 Ϳ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
input current
115 Vac
230 Vac
inrush current
115 Vac, full load, cold start
230 Vac, full load, cold start
OUTPUT
conditions/description
47
63
Hz
1.5
0.7
A
A
30
60
A
A
max
units
W\S
±1
load regulation
hold-up time
115 Vac, full load
230 Vac, full load
adjustability
adjustable with built-in trim pot1
TI
1. Adjustment of 5 V output only.
N
WHPSHUDWXUHFRHϒFLHQW
PROTECTIONS
conditions/description
over voltage protection
VKXWGRZQDQGODWFKRϑUHFRYHUDIWHUUHVWDUW
overload protection
hiccup mode, automatically recovers
short circuit protection
continuous, automatically recovers
C
O
SAFETY & COMPLIANCE
min
N
parameter
parameter
Vac
Vdc
min
line regulation
Note:
units
264
370
U
parameter
W\S
ED
frequency
max
85
120
conditions/description
±5
%
±0.03
%/°C
10
50
ms
ms
±5
%
W\S
110
min
W\S
isolation voltage
input to output
input to case
output to case
isolation resistance
input to output at 500 Vdc @ 25°C
safety approvals
UL 60950-1, Intertek EN 60950-1
EMI/EMC
EN 55022 (CISPR22) Class B, EN 61000 -3-2,-3,-4-2,3,4,5,6,8,11; EN 55024
at 240 Vac
MTBF
MIL-HDBK-217F(25°C)
RoHS
2011/65/EU
max
units
7
V
160
%
max
units
3,000
1,500
500
Vac
Vac
Vac
100
0
3.5
IS
leakage current
%
300,000
mA
hrs
D
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
operating humidity
non-condensing
storage humidity
cui.com
W\S
max
units
-10
60
°C
-20
85
°C
20
90
%
10
95
%
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: VGD-60 Ϳ DESCRIPTION: AC-DC POWER SUPPLY
date 07/10/2018 Ϳ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
129 x 98 x 38 (5.1 x 3.9 x 1.5 inch)
min
cooling method
free air convection (see derating curve below)
W\S
max
mm
433
-10
1
MECHANICAL DRAWING
5
6
N
8.20 0.323
O
9.50 0.374
C
120.00 4.724
18.50 0.728
3.50 0.138
9.50 0.374
18.00 0.709
38.00 1.496
28.50 1.122
IS
3.50 0.138
75.50 2.972
M3 (3 PLCS)
129.00 5.079
73.50 2.894
D
3.50 0.138
(2 PLCS)
M3 (2 PLCS)
85.50 3.366
33.00 1.299
98.00 3.858
31.00 1.220
4.50 0.177
4
TI
units mm[inches]
tolerance:
PPXQOHVVRWKHUZLVHVSHFL¿HG
32.50 1.280
3
N
2
U
DERATING CURVES
9.00 0.354
g
ED
weight
6.50 0.256
units
122.50 4.823
7.00 0.276
3.50 0.138
cui.com
PIN CONNECTIONS
Pin
Function
1
ac line
2
ac neutral
3
FG
4
COM
5
+V2
6
COM
7
+V1
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: VGD-60 Ϳ DESCRIPTION: AC-DC POWER SUPPLY
date 07/10/2018 Ϳ page 4 of 4
REVISION HISTORY
description
date
10/26/2011
1.0
initial release
1.01
updated capacitor values for ripple measurements
1.02
9,Q¿QLW\EUDQGLQJUHPRYHG
1.03
added minimum current requirements
1.04
updated drawing
1.05
updated datasheet
ED
rev.
04/20/2012
08/21/2012
10/29/2013
01/15/2014
07/10/2018
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
&8,RϑHUVDWZR\HDUOLPLWHGZDUUDQW\&RPSOHWHZDUUDQW\LQIRUPDWLRQLVOLVWHGRQRXUZHEVLWH
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
OLIHVXSSRUWGHYLFHRUV\VWHPZKRVHIDLOXUHWRSHUIRUPFDQEHUHDVRQDEO\H[SHFWHGWRFDXVHWKHIDLOXUHRIWKHOLIHVXSSRUWGHYLFHRUV\VWHPRUWRDϑHFWLWVVDIHW\RUHϑHFWLYHQHVV
很抱歉,暂时无法提供与“VGD-60-D512”相匹配的价格&库存,您可以联系我们找货