rev. rev. page date 1 of 2
09/2007
PART NUMBER: VKG series
DESCRIPTION: single output dc-dc converter
features
·built-in heatsink ·high density ·2:1 input range ·high reliability ·over-temp protection ·undervoltage lockout ·designed for rectified 220 V ac and 380 V ac ·overload protection ·long life ·six side metal shielding ·1000 V dc isolation ·able to withstand high vibration and shock ·perfectly suited for: transportation, mining, power plant, and power distribution
model number VKG100-D300-S05 VKG150-D300-S12 VKG200-D300-S15 VKG250-D300-S24 VKG300-D300-S48 VKG500-D300-S15 VKG100-D600-S05 VKG150-D600-S12 VKG200-D600-S15 VKG250-D600-S24 VKG300-D600-S48 VKG500-D600-S24
input voltage 300 300 300 300 300 300 600 600 600 600 600 600
input range 200-400 200-400 200-400 200-400 200-400 200-400 400-800 400-800 400-800 400-800 400-800 400-800
output voltage 5 V dc 12 V dc 15 V dc 24 V dc 48 V dc 15 V dc 5 V dc 12 V dc 15 V dc 24 V dc 48 V dc 24 V dc
output current 20 A 12.5 A 13.3 A 10.4 A 6.25 A 33.3 A 20 A 12.5 A 13.3 A 10.4 A 6.25 A 20.8 A
ripple & noise 50 mVpp 120 mVpp 150 mVpp 200 mVpp 400 mVpp 150 mVpp 50 mVpp 120 mVpp 150 mVpp 200 mVpp 400 mVpp 200 mVpp
efficiency 87% 89% 90% 91% 92% 90% 87% 89% 90% 91% 92% 91%
INPUT
input voltage range input reversal protection 300 V dc 200-400 V dc 600 V dc 400-800 V dc built-in, requires an input fuse
OUTPUT
voltage accuracy ripple & noise line regulation load regulation temperature coefficient current limit, % nominal output transient response ±1%
很抱歉,暂时无法提供与“VKG500-D600-S24”相匹配的价格&库存,您可以联系我们找货