0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VYB10W-Q48-S12

VYB10W-Q48-S12

  • 厂商:

    CUI

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 1 输出 12V 833mA 18V - 72V 输入

  • 数据手册
  • 价格&库存
VYB10W-Q48-S12 数据手册
Additional Resources: Product Page date 08/29/2012 page 1 of 5 SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER 8 ~ 10 W output industry standard pinout 4:1 input range (9 ~ 36 V, 18 ~ 72 V) single and dual outputs 1,500 V isolation short circuit protection wide temperature operation (-40 ~ 85°C) efficiency up to 83% U • • • • • • • • ED FEATURES input voltage output voltage range (Vdc) (Vdc) min (mA) 3.3 VYB10W-Q24-S32 9 ~ 36 VYB10W-Q24-S5 9 ~ 36 VYB10W-Q24-S12 9 ~ 36 9 ~ 36 9 ~ 36 output power ripple1 noise1 efficiency max (mA) max (W) max (mVp-p) max (mVp-p) typ (%) 240 2,400 8 50 150 76 5 200 2,000 10 50 150 79 12 83 833 10 50 150 81 15 67 666 10 50 150 82 ±5 ±100 ±1,000 10 50 150 80 N VYB10W-Q24-S15 VYB10W-Q24-D5 output current TI MODEL N RoHS 9 ~ 36 ±12 ±42 ±416 10 50 150 82 9 ~ 36 ±15 ±33 ±333 10 50 150 83 2 VYB10W-Q48-S3 18 ~ 72 3.3 240 2,400 8 50 150 77 VYB10W-Q48-S52 18 ~ 72 5 200 2,000 10 50 150 78 VYB10W-Q48-S12 VYB10W-Q48-S15 VYB10W-Q48-D52 18 ~ 72 12 83 833 10 50 150 82 18 ~ 72 15 67 666 10 50 150 83 18 ~ 72 ±5 ±100 ±1,000 10 50 150 78 18 ~ 72 ±12 ±42 ±416 10 50 150 82 18 ~ 72 ±15 ±33 ±333 10 50 150 83 IS C VYB10W-Q48-D12 O VYB10W-Q24-D12 VYB10W-Q24-D15 VYB10W-Q48-D15 Notes: 1. Ripple and noise are measured at 20 MHz BW with 10μF tantalum capacitor and 1μF ceramic capacitor across output 2. PWM mode, others PFM mode D PART NUMBER KEY VYB10W - QXX - X XX - X Output S = single output D = dual output Base Number Input Voltage Output Voltage cui.com Remote On/Off "blank" = No A = Yes Additional Resources: Product Page CUI Inc │ SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 2 of 5 INPUT conditions/description operating input voltage start up time nominal imput, full load filter PI type min typ max units 9 18 24 48 36 72 Vdc Vdc 180 OUTPUT min line regulation measured from low line to high line load regulation measured from 10% to full load voltage accuracy positive, refer to recommended circuit negative, refer to recommended circuit transient recovery time 25% load step change (PWM type) 25% load step change (PFM type) transient peak deviation cross regulation main output 55% supplemental output from 10-100% switching frequency 100% load, input voltage range 1. Dual output models unbalanced load: ±5% PROTECTIONS TI temperature coefficient Notes: conditions/description short circuit protection continuous, automatic recovery N parameter typ max ±0.2 ±0.5 % ±0.5 ±11 % ±1 ±3 ±3 ±5 % % 200 10 500 20 ms ms ±3 ±5 % U conditions/description N parameter ms ED parameter ±5 300 units % kHz ±0.03 %/°C min typ max units min typ max units SAFETY AND COMPLIANCE conditions/description isolation voltage tested for 1 minute at 1 mA max. 1,500 isolation resistance at 500 Vdc 1,000 isolation capacitance RoHS compliant input to output, 100 kHz / 1 V Vdc MΩ 1,000 pF yes 1,000,000 IS C MTBF O parameter hours ENVIRONMENTAL parameter conditions/description min case operating temperature maximum case temperature typ -40 during operation storage temperature -55 storage humidity non-condensing temperature rise 100% load lead temperature 1.5 mm from the case for 10 seconds max units 85 °C 105 °C 105 °C 95 D 40 cui.com % °C 300 °C Additional Resources: Product Page CUI Inc │ SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 3 of 5 DERATING CURVES 80 60 40 20 -40 -20 0 20 40 60 80 100 120 U Ambient Temperature (°C) ED Load (%) 100 MECHANICAL conditions/description min dimensions 2.00 x 1.00 x 0.44 inch (50.8 x 25.4 x 11.2 mm) case material aluminum typ N parameter units 23.5 g TI weight max MECHANICAL DRAWING 5.08 [0.200] IS C 10.16 0.400 3 2.54 [0.100] 20.32 [0.800] 5.08 0.200 4 25.40 1.000 1 Pin section tolerances:±0.10m m[±0.004inch] General tolerances:±0.25m m [±0.010inch] 7.62 0.300 6 4 2 3 2 5 1 50.80 2.000 20.32 0.800 6 5 10.16 0.400 PIN CONNECTIONS Dual Pin S ingle 1 GND GND D BOTTOM VIEW 2 3 4 5 Vin + Vo No P in 0V Vin + Vo 0V -Vo 6* No Pin* No Pin* *Pin 6 added for optional Remote on/off cui.com 2.54 [0.100] O 1.00 0.039 (6 PLCS) ∅1.20 [0.047] 20.32 [0.800] N 4.10 0.161 (6 PLCS) 7.62 [0.300] RECOMMENDED FOOTPRINT (TOP VIEW) 11.20 0.441 Additional Resources: Product Page CUI Inc │ SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 4 of 5 APPLICATION NOTES Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Recommended Circuit The VYB10W series has been tested according to the following recommended testing circuit. This series should be tested under load. (see Figure 1) Dual Output Single Output 2 Vin Cin GND D1 Ic R Vc 6 3 DC/DC GND 0V 5 3 DC/DC Cin Cout 1 6 2 Vin +Vo +Vo U Figure 1 D1 Ic R Cout 0V 4 Cout 1 -Vo 5 N Vc ED 1. If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. If the capacitance is too big, a startup problem might arise. The maximum allowable capacitance to ensure safe and reliable operation is listed in Table 1. Table 1 Cout (μF) Dual Vout (Vdc) Cout (μF) 3.3 2,200 -- -- 5 1,000 ±5 680 12 470 ±12 330 15 330 ±15 220 Remote On/Off When open or high impedance,the converter will be on; When this pin is ‘high’; the converter will shutdown; It should be noted that the input current (Ic) should between 5 ~ 10 mA, exceeding the maximum 20 mA will cause permanent damage to the converter. The value of R Can be derived as follows : N 3. Cin: 10 ~ 47 μF Cout: 10 μF / 100 mA Single Vout (Vdc) TI General: 4. O R= VC - VD - 1.0 IC Input Current When using an unstable power source, please ensure the output voltage and ripple voltage do not excced indexes of the converter. The preceding power source must be able to provide for converter sufficient starting current Ip. IS C General: Ip ≤1.6*Iin-max No parallel connection or plug and play D 5. cui.com Additional Resources: Product Page CUI Inc │ SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 5 of 5 REVISION HISTORY description date 1.0 initial release 08/08/2011 1.01 V-Infinity branding removed ED rev. 08/29/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VYB10W-Q48-S12 价格&库存

很抱歉,暂时无法提供与“VYB10W-Q48-S12”相匹配的价格&库存,您可以联系我们找货

免费人工找货