0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VYB15W-Q24-D5-H

VYB15W-Q24-D5-H

  • 厂商:

    CUI

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 2 输出 5V -5V 1.5A,1.5A 9V - 36V 输入

  • 数据手册
  • 价格&库存
VYB15W-Q24-D5-H 数据手册
Additional Resources: Product Page date 08/29/2012 page 1 of 6 SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER up to 15W output industry standard pinout 4:1 input range (9 ~ 36 V, 18 ~ 75 V) single and dual outputs 1,500 V isolation short circuit, over current, and over voltage protections wide temperature operation (-40 ~ 85°C) efficiency up to 87% U • • • • • • • • ED FEATURES input voltage output voltage range (Vdc) (Vdc) min (mA) 3.3 VYB15W-Q24-S3 9 ~ 36 VYB15W-Q24-S5 9 ~ 36 VYB15W-Q24-S12 9 ~ 36 9 ~ 36 9 ~ 36 output power ripple1 noise1 efficiency max (mA) max (W) max (mVp-p) max (mVp-p) typ (%) 400 4,000 13.2 150 150 80 5 300 3,000 15 150 150 82 12 125 1,250 15 150 150 85 15 100 1,000 15 150 150 85 ±5 ±150 ±1,500 15 50 100 86 N VYB15W-Q24-S15 VYB15W-Q24-D5 output current TI MODEL N RoHS 9 ~ 36 ±12 ±63 ±625 15 50 100 87 9 ~ 36 ±15 ±50 ±500 15 50 100 87 VYB15W-Q48-S3 18 ~ 75 3.3 400 4,000 13.2 150 150 81 VYB15W-Q48-S5 18 ~ 75 5 300 3,000 15 150 150 83 VYB15W-Q48-S12 VYB15W-Q48-S15 VYB15W-Q48-D5 18 ~ 75 12 125 1,250 15 150 150 85 18 ~ 75 15 100 1,000 15 150 150 85 18 ~ 75 ±5 ±150 ±1,500 15 50 100 84 18 ~ 75 ±12 ±63 ±625 15 50 100 87 18 ~ 75 ±15 ±50 ±500 15 50 100 87 IS C VYB15W-Q48-D12 O VYB15W-Q24-D12 VYB15W-Q24-D15 VYB15W-Q48-D15 Notes: 1. Ripple and noise are measured at 20 MHz BW with 10μF tantalum capacitor and 1μF ceramic capacitor across output D PART NUMBER KEY VYB15W - QXX - X XX - X Output S = single output D = dual output Base Number Input Voltage Output Voltage cui.com Heatsink "blank" = No H = Yes Additional Resources: Product Page CUI Inc │ SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 2 of 6 INPUT conditions/description operating input voltage min typ max units 9 18 24 48 36 75 Vdc Vdc start-up time 10 dual output models power power power power Remote on/off1 all models single output models dual output models filter single output models, LC dual output models, PI type Notes: up 24 V input up 48 V input down 24 V input down 48 V input 9.0 17.8 7.8 16.0 module off module on (or open circuit) module on (or open circuit) 0 3.5 3.5 Vdc Vdc Vdc Vdc 1.2 40 12 Vdc Vdc Vdc U dual output models under voltage lockout ms ED parameter 1. The on/off pin voltage is referenced to GND N OUTPUT parameter conditions/description typ max units line regulation measured from low line to high line min ±0.2 ±0.5 % ±0.5 ±1 % ±1 ±3 % 200 500 μs ±2 ±3 ±5 ±5 % % ±5 % measured from 10% to full load refer to recommended circuit transient recovery time 25% step load charge transient peak deviation single output models dual output models cross regulation dual output models TI load regulation voltage accuracy 25% rated load N main output 55%, supplemental output from 10~100% load single output models switching frequency 100% load, input voltage range single output models dual output models temperature coefficient PROTECTIONS parameter conditions/description over current protection single output models dual output models input voltage range input voltage range single output models 3.3 V 5V 12 V 15 V ±5 V ±12 V ±15 V Vdc 300 400 kHz kHz ±0.02 %/°C min typ max units 120 120 130 140 150 150 % % dual output models 3.9 6.2 15 18 ±6.1 ±15 ±18 D over voltage protection ±10% hiccups, continuous, automatic recovery IS C short circuit protection O adjustability cui.com Vdc Vdc Vdc Vdc Vdc Vdc Vdc Additional Resources: Product Page CUI Inc │ SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 3 of 6 SAFETY AND COMPLIANCE conditions/description isolation voltage tested for 1 minute at 1 mA max. 1,500 min Vdc isolation resistance at 500 Vdc 1,000 MΩ isolation capacitance input to output, 100 kHz / 0.1 V single output models dual output models RoHS compliant yes MTBF M1L-HDBK-217F max pF pF 1,000,000 min hours typ U conditions/description case operating temperature max units 85 °C 105 °C 125 °C -40 maximum case temperature during operation storage temperature -55 non-condensing temperature rise 100% load 5 lead temperature 1.5 mm from the case for 10 seconds TI N storage humidity DERATING CURVES units 1,000 2,000 ENVIRONMENTAL parameter typ ED parameter 95 % 40 °C 300 °C output power vs. ambient temperature N single output models 100 dual output models 100 2 80 Load (%) 1 60 O ≤5V models Load (%) 2 80 40 40 20 -40 0 20 30 40 50 1 60 20 60 70 80 -40 0 20 IS C Ambient Temperature (°C) D Load (%) 100 >5V models 80 2 1 60 40 20 -40 0 20 30 40 50 60 30 40 50 60 Ambient Temperature (°C) 70 80 Ambient Temperature (°C) cui.com 1 without heat sink 2 with heatsink 70 80 Additional Resources: Product Page CUI Inc │ SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 4 of 6 MECHANICAL conditions/description dimensions 2.00 x 1.00 x 0.44 inch (50.8 x 25.4 x 11.2mm) case material nickel-coated copper (six-sided) weight min typ max units ED parameter 40 55 with heat sink MECHANICAL DRAWING g g RECOMMENDED FOOTPRINT (TOP VIEW) TI 10.16 0.400 3 7.62 0.300 2 4 4 2 3 +0.031 25.40+0.80 -0.00 [1.000 -0.000 ] 1 2.54[0.100] 5 2.54[0.100] 20.32[0.800] 80 +0. 031 50.80 +0. -0.00 [2.000 -0.000 ] Pin section tolerances:±0.10m m[±0.004inch] General tolerances:±0.25m m [±0.010inch] 5.08 0.200 5 10.16 0.400 O N BOTTOM VIEW THERMAL PAD 25.40 1.000 PIN CONNECTIONS Pin S ingle Dual 1 2 3 4 5 GND Vin + Vo Trim 0V GND Vin + Vo 0V -Vo 6 On/Off On/Off *Pin 6 added for optional Remote on/off IS C HEATSINK CLAMP 17.50 0.689 D 50.80 2.000 6 24.90 0.980 1 6 N 20.32 0.800 ∅1.20 [0.047] U 4.10 0.161 1.00 0.039 5.08[0.200] 3.50 0.138 10.16[0.400] 11.80 0.465 20.32[0.800] 11.20 0.441 22.50 0.886 MAX 30.00 1.181 MAX cui.com Additional Resources: Product Page CUI Inc │ SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 5 of 6 APPLICATION NOTES Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Recommended Circuit The VYB15W series has been tested according to the following recommended testing circuit. This series should be tested under load. (see Figure 1) Single Output DC +Vo C out C in 0V G ND DC DC U DC Cin Cout 0V C out GND N Figure 1 Dual Output Vin +Vo Vin ED 1. -Vo If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. If the capacitance is too big, a startup problem might arise. The maximum allowable capacitance to ensure safe and reliable operation is listed in Table 1. Table 1 Cout (μF) Cin (μF) Dual Vout (Vdc) TI Single Vout (Vdc) Cout (μF) Cin (μF) 3.3 470 100 -- -- 100 5 470 100 ±5 ±220 100 12 220 100 ±12 ±100 100 15 220 100 ±15 ±100 100 O N 3. Trim Application and Trim Resistance (Single Output Models) Formula for trim resistance Application circuit for TRIM (Part in broken line is the interior of models) a= Vref R1 Vo’-Vref down: R T = aR1 -R3 R 1-a a= Vo’-Vref R2 Vref IS C Note: Value for R1, R2, R3, and Vref refer to the following table. R1 R2 aR2 -R3 R 2-a +Vo +Vo V ref up: R = R3 RT R1 Trim V ref R T: Trim resistance R3 Trim a: User-defined parameter, no actual meaning. Vo’: Trim up/down voltage. RT R2 Vo 3.3 (Vdc) 5 (Vdc) 12 (Vdc) 15 (Vdc) Resistance 0V R1 (KΩ) 4.801 2.883 10.971 14.497 Trimup Trimdown R2 (KΩ) 2.863 2.864 2.864 2.864 R3 (KΩ) 15 10 17.8 17.8 Vref (V) 1.24 2.5 2.5 2.5 D 0V cui.com Additional Resources: Product Page CUI Inc │ SERIES: VYB15W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 6 of 6 REVISION HISTORY description date 1.0 initial release 08/08/2011 1.01 V-Infinity branding removed ED rev. 08/29/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VYB15W-Q24-D5-H 价格&库存

很抱歉,暂时无法提供与“VYB15W-Q24-D5-H”相匹配的价格&库存,您可以联系我们找货

免费人工找货