0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VYB20W-Q24-D12

VYB20W-Q24-D12

  • 厂商:

    CUI

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 2 输出 12V -12V 833mA,833mA 9V - 36V 输入

  • 数据手册
  • 价格&库存
VYB20W-Q24-D12 数据手册
Additional Resources: Product Page date 08/29/2012 page 1 of 6 SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER up to 20W output industry standard pinout 4:1 input range (9 ~ 36 V, 18 ~ 75 V) single and dual outputs 1,500 V isolation short circuit, over current, and over voltage protection wide temperature operation (-40 ~ 85°C) efficiency up to 88% U • • • • • • • • ED FEATURES input voltage output voltage range (Vdc) (Vdc) min (mA) 3.3 VYB20W-Q24-S3 9 ~ 36 VYB20W-Q24-S5 9 ~ 36 VYB20W-Q24-S12 9 ~ 36 9 ~ 36 9 ~ 36 VYB20W-Q24-D5 VYB20W-Q24-D12 ripple1 noise1 efficiency max (mA) max (W) max (mVp-p) max (mVp-p) typ (%) 500 5,000 16.5 150 150 83 5 400 4,000 20 150 150 86 12 167 1,667 20 150 150 87 15 133 1,333 20 150 150 88 24 83 834 20 150 150 88 9 ~ 36 ±5 ±200 ±2,000 20 50 100 84 9 ~ 36 ±12 ±83 ±833 20 50 100 87 9 ~ 36 ±15 ±67 ±667 20 50 100 87 18 ~ 75 3.3 5,000 16.5 150 150 83 O VYB20W-Q24-D15 VYB20W-Q48-S3 output power N VYB20W-Q24-S15 VYB20W-Q24-S24 output current TI MODEL N RoHS 500 VYB20W-Q48-D5 18 ~ 75 ±5 ±200 ±2000 20 50 100 85 VYB20W-Q48-D12 18 ~ 75 ±12 ±83 ±833 20 50 100 87 VYB20W-Q48-D15 18 ~ 75 ±15 ±67 ±667 20 50 100 88 VYB20W-Q48-S5 VYB20W-Q48-S12 VYB20W-Q48-S15 5 400 4,000 20 150 150 87 12 167 1,667 20 150 150 88 18 ~ 75 15 133 1,333 20 150 150 88 18 ~ 75 24 83 834 20 150 150 88 IS C VYB20W-Q48-S24 18 ~ 75 18 ~ 75 Notes: 1. Ripple and noise are measured at 20 MHz BW with 10μF tantalum capacitor and 1μF ceramic capacitor across output D PART NUMBER KEY VYB20W - QXX - X XX - X Output S = single output D = dual output Base Number Input Voltage Output Voltage cui.com Heatsink "blank" = No H = Yes Additional Resources: Product Page CUI Inc │ SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 2 of 6 INPUT conditions/description operating input voltage min typ max units 9 18 24 48 36 75 Vdc Vdc start-up time 10 under voltage lockout all models all models single output models dual output models all models power power power power power Remote on/off1 all models single output models dual output models module off module on (or open circuit) module on (or open circuit) filter single output models, LC dual output models, PI type Vdc Vdc Vdc Vdc Vdc 0 3.5 3.5 1.2 12 12 Vdc Vdc Vdc typ max units U 1. The on/off pin voltage is referenced to GND OUTPUT parameter 9.0 17.8 8.0 7.8 16.0 conditions/description N Notes: up 24 V input up 48 V input down 24 V input down 24 V input down 48 V input ms ED parameter min measured from low line to high line ±0.2 ±0.5 % measured from 10% to full load ±0.5 ±1 % TI line regulation load regulation voltage accuracy refer to recommended circuit ±1 ±3 % transient recovery time 25% step load charge 200 500 μs transient peak deviation 25% rated load dual output models N cross regulation single output models switching frequency 100% load, input voltage range PROTECTIONS parameter short circuit protection conditions/description ±5 % ±5 % ±10% Vdc 400 kHz ±0.02 %/°C min typ max units 120 120 130 140 150 150 % % hiccups, continuous, automatic recovery single output models dual output models input voltage range input voltage range single output models 3.3 V 5V 12 V 15 V 24 V ±5 V ±12 V ±15 V IS C over current protection O adjustability temperature coefficient ±3 main output 55%, supplemental output from 10~100% load over voltage protection D dual output models 3.9 6.2 15 18 28 ±6.1 ±15 ±18 cui.com Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Additional Resources: Product Page CUI Inc │ SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 3 of 6 SAFETY AND COMPLIANCE conditions/description isolation voltage tested for 1 minute at 1 mA max. 1,500 min Vdc isolation resistance at 500 Vdc 1,000 MΩ isolation capacitance input to output, 100 kHz / 0.1 V single output models dual output models RoHS compliant yes MTBF M1L-HDBK-217F max pF pF 1,000,000 min hours typ U conditions/description case operating temperature max units 85 °C 105 °C 125 °C -40 maximum case temperature during operation storage temperature -55 non-condensing temperature rise 100% load 5 lead temperature 1.5 mm from the case for 10 seconds TI N storage humidity DERATING CURVES units 1,000 2,000 ENVIRONMENTAL parameter typ ED parameter 95 % 40 °C 300 °C output power vs. ambient temperature N single output models 100 dual output models 100 2 80 Load (%) 1 60 O ≤5V models Load (%) 2 80 40 40 20 -40 0 20 30 40 50 1 60 20 60 70 80 -40 0 20 IS C Ambient Temperature (°C) D Load (%) 100 >5V models 80 2 1 60 40 20 -40 0 20 30 40 50 60 30 40 50 60 Ambient Temperature (°C) 70 80 Ambient Temperature (°C) cui.com 1 without heat sink 2 with heatsink 70 80 Additional Resources: Product Page CUI Inc │ SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 4 of 6 MECHANICAL conditions/description dimensions 2.00 x 1.00 x 0.44 inch (50.8 x 25.4 x 11.2mm) case material nickel-coated copper (six-sided) weight min typ max units ED parameter 40 55 with heat sink MECHANICAL DRAWING g g 4 2 3.50 0.138 5.08[0.200] 4.10 0.161 20.32 0.800 3 7.62 0.300 2 4 5.08 0.200 6 24.90 0.980 5 O THERMAL PAD HEATSINK IS C D 22.50 0.886 MAX PIN CONNECTIONS Pin S ingle Dual 1 2 3 4 5 GND Vin + Vo Trim 0V GND Vin + Vo 0V -Vo 6 On/Off On/Off *Pin 6 added for optional Remote on/off CLAMP 17.50 0.689 50.80 2.000 2.54[0.100] 20.32[0.800] 80 +0. 031 50.80 +0. -0.00 [2.000 -0.000 ] Pin section tolerances:±0.10m m[±0.004inch] General tolerances:±0.25m m [±0.010inch] 10.16 0.400 25.40 1.000 3 10.16 0.400 N 1 TI 1.00 0.039 +0.031 25.40+0.80 -0.00 [1.000 -0.000 ] 1 2.54[0.100] 5 20.32[0.800] 6 N 11.80 0.465 ∅1.20 [0.047] U 11.20 0.441 10.16[0.400] RECOMMENDED FOOTPRINT (TOP VIEW) TOLERANCE: ±0.3mm UNLESS OTHERWISE SPECIFIED 30.00 1.181 MAX cui.com Additional Resources: Product Page CUI Inc │ SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 5 of 6 APPLICATION NOTES Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Recommended Circuit The VYB20W series has been tested according to the following recommended testing circuit. This series should be tested under load. (see Figure 1) Single Output DC DC +Vo C out C in 0V G ND DC DC U Cin Cout 0V C out GND N Figure 1 Dual Output Vin +Vo Vin ED 1. -Vo If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. If the capacitance is too big, a startup problem might arise. The maximum allowable capacitance to ensure safe and reliable operation is listed in Table 1. Single Vout (Vdc) Cin (μF) Dual Vout (Vdc) Cout (μF) Cin (μF) 3.3 470 100 -- -- -- 5 470 100 ±5 ±220 100 12 220 100 ±12 ±100 100 15 220 100 ±15 ±100 100 24 100 100 -- -- -- TI Table 1 Cout (μF) O N 3. Trim Application and Trim Resistance (Single Output Models) Formula for trim resistance IS C Application circuit for TRIM (Part in broken line is the interior of models) RT R1 R3 Trim V ref D Trimup Vref R1 Vo’-Vref down: R T = aR1 -R3 R 1-a a= Vo’-Vref R2 Vref R T: Trim resistance R3 Trim a: User-defined parameter, no actual meaning. Vo’: Trim up/down voltage. RT R2 0V a= Note: Value for R1, R2, R3, and Vref refer to the following table. R1 R2 aR2 -R3 R 2-a +Vo +Vo V ref up: R = Vo 3.3 (Vdc) 5 (Vdc) 12 (Vdc) 15 (Vdc) 24 (Vdc) Resistance 0V R1 (KΩ) 4.801 2.883 10.971 14.497 24.872 Trimdown R2 (KΩ) 2.863 2.864 2.864 2.864 2.864 R3 (KΩ) 15 10 17.8 17.8 20 Vref (V) 1.24 2.5 2.5 2.5 2.5 cui.com Additional Resources: Product Page CUI Inc │ SERIES: VYB20W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 6 of 6 REVISION HISTORY description date 1.0 initial release 08/09/2011 1.01 V-Infinity branding removed ED rev. 08/29/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VYB20W-Q24-D12 价格&库存

很抱歉,暂时无法提供与“VYB20W-Q24-D12”相匹配的价格&库存,您可以联系我们找货

免费人工找货