Additional Resources:
Product Page
date
08/17/2021
page
1 of 7
SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
FEATURES
MODEL
U
ED
15 watts
high operating temp -40 to +70°C
4,000 Vac isolation
designed to meet UL 1741; EN 62109 approved
board mounted
input voltage range of 200~1,500 Vdc
low ripple & noise
OVP protection
output short circuit protection
N
•
•
•
•
•
•
•
•
•
output
voltage
output
current
output
power
ripple
& noise1
HϒFLHQF\2
range
(Vdc)
(Vdc)
min
(A)
max
(A)
max
(W)
max
(mVp-p)
W\S
(%)
AE15-UW-S12
200~1500
12
0
1.25
15
300
71
AE15-UW-S15
200~1500
15
AE15-UW-S24
200~1500
24
0
1.00
15
300
72
0
0.625
15
300
74
TI
input
voltage
1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF electrolytic and 1 µF ceramic capacitors on the output.
2. Measured at 800 Vdc input voltage, full load.
$OOVSHFL¿FDWLRQVDUHPHDVXUHGDW7D &KXPLGLW\QRPLQDOLQSXWYROWDJHDQGUDWHGRXWSXWORDGXQOHVVRWKHUZLVHVSHFL¿HG
O
PART NUMBER KEY
N
Notes:
Output Voltage
Base Number
D
IS
C
AE15-UW - SXX
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 2 of 7
INPUT
parameter
conditions/description
min
under voltage shutdown
shut-down range
turn-on range
current
at 200 Vdc
at 800 Vdc
at 1500 Vdc
inrush current
at 200 Vdc
at 800 Vdc
at 1500 Vdc
input fuse
4 A / 1500 Vdc (external)
maximum capacitive load
from low line to high line, full load
load regulation
from 0% to full load
delay time
IURP9LQ 9WRRIUDWHGRXSWXWYROWDJH
N
parameter
conditions/description
over voltage protection
12 Vdc, 15 Vdc output models
24 Vdc output model
automatic recovery
O
over current protection
185
195
Vdc
Vdc
120
30
16
mA
mA
mA
TI
line regulation
short circuit protection
170
180
min
voltage accuracy
PROTECTIONS
Vdc
U
conditions/description
12 Vdc output model
15 Vdc output model
24 Vdc output model
at full load
units
1500
N
parameter
WHPSHUDWXUHFRHϒFLHQW
W\S
30
80
150
OUTPUT
switching frequency
max
200
ED
operating input voltage
min
W\S
A
A
A
max
units
2,000
1,200
470
Nj)
Nj)
Nj)
±2
%
±1
%
±1
%
2
s
65
kHz
±0.02
%/°C
W\S
120
max
units
20
30
Vdc
Vdc
320
%
max
units
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
input to output for 1 minute
W\S
4,000
C
isolation voltage
min
CSA, EN 62109
conducted emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
radiated emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
ESD
IEC/EN61000-4-2, contact ± 6kV/air ± 8kV, class B
radiated immunity
IEC/EN61000-4-3, 10V/m, class A
()7EXUVW
IEC/EN61000-4-4, ± 2kV, class B (external circuit required, see Figure 2)
surge
IEC/EN61000-4-5, line-line ± 1kV, class B (external circuit required, see Figure 2)
conducted immunity
IEC/EN61000-4-6, 10 Vr.m.s, class A
PDJQHWLF¿HOGLPPXQLW\
IEC/EN61000-4-8, 10 A/m, class A
07%)
as per MIL-HDBK-217F, 25°C
RoHS
yes
D
IS
safety approvals
Vac
300,000
cui.com
hours
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
70
°C
-40
85
°C
95
%
5000
m
storage humidity
non-condensing
altitude
see derating curves
ED
storage temperature
W\S
SOLDERABILITY
parameter
conditions/description
min
W\S
max
units
hand soldering
for 3~5 seconds
350
360
370
°C
wave soldering
for 5~10 seconds
255
260
265
°C
max
units
U
MECHANICAL
conditions/description
dimensions
125.00 x 75.00 x 40.00 [4.921 x 2.953 x 1.575 inch]
case material
EODFNÀDPHUHWDUGDQWKHDWSURRISODVWLF8/9
weight
units: mm [inch]
tolerance: ±0.50[±0.020]
pin diameter tolerance: ±0.10[±0.004]
pin height tolerance: ±1.50[±0.059]
1
-Vin
2
+Vin
NC
4
-Vout
5
+Vout
C
3
O
3,1&211(&7,216
Function
300
N
In high vibration environments, this series
should be mounted with screws.
tightening torque: max 0.4 N*m
W\S
TI
MECHANICAL DRAWING
PIN
min
N
parameter
D
IS
1& QRFRQQHFWLRQ
Recommended PCB Layout
7RS9LHZ
cui.com
mm
g
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 4 of 7
D
IS
C
O
N
TI
N
U
ED
DERATING CURVES
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 5 of 7
D
IS
C
O
N
TI
N
U
ED
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 6 of 7
APPLICATION CIRCUIT
Fuse
4 A / 1500 Vdc
4 A / 1500 Vdc
24
4 A / 1500 Vdc
1
C2
Nj)
120
796
SMBJ20A
1
120
SMBJ20A
1
68
SMBJ30A
N
TI
12
15
C1
Nj)
N
Vout
(Vdc)
U
Table 1
ED
Figure 1
O
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
IS
C
FUSE
4 A/1500 Vdc
C7, C8, C9, C10
104K/275 Vac
C3, C4, C5, C6
47 µF/450 Vdc
R1, R2, R3, R4
0:
LDM
330 µH/1 A
LCM
7 mH/1 A
D
1RWH6HHDOVR7DEOH
1RWHV
&LVDFHUDPLFFDSDFLWRUXVHGWR¿OWHUKLJKIUHTXHQF\QRLVH
2. C2 is electrolytic and is recommended to be high frequency and low resistance. For capacitance and current of the capacitor, refer to the datasheet provided by the
manufacturer. Capacitance withstand voltage derating should be 80% or above.
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE15-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 08/17/2021 Ϳ page 7 of 7
REVISION HISTORY
description
date
09/13/2017
1.0
initial release
1.01
updated datasheet
1.02
changed external input fuse recommendation
1.03
company logo updated
1.04
ED
rev.
03/05/2018
07/24/2019
04/12/2021
GHUDWLQJFXUYHVHϒFLHQF\FXUYHVDQGFLUFXLW¿JXUHVXSGDWHG
08/17/2021
D
IS
C
O
N
TI
N
U
7KHUHYLVLRQKLVWRU\SURYLGHGLVIRULQIRUPDWLRQDOSXUSRVHVRQO\DQGLVEHOLHYHGWREHDFFXUDWH
Headquarters
20050 SW 112th Ave.
7XDODWLQ25
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
&8,RϑHUVDWZR\HDUOLPLWHGZDUUDQW\&RPSOHWHZDUUDQW\LQIRUPDWLRQLVOLVWHGRQRXUZHEVLWH
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
OLIHVXSSRUWGHYLFHRUV\VWHPZKRVHIDLOXUHWRSHUIRUPFDQEHUHDVRQDEO\H[SHFWHGWRFDXVHWKHIDLOXUHRIWKHOLIHVXSSRUWGHYLFHRUV\VWHPRUWRDϑHFWLWVVDIHW\RUHϑHFWLYHQHVV