Additional Resources:
Product Page
date
11/11/2022
page
1 of 7
SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
FEATURES
MODEL
U
ED
40 watts
high operating temp -40 to +70°C
4,000 Vac isolation
UL 1741; EN 62109 approved
board mounted
input voltage range of 200~1,500 Vdc
low ripple & noise
OVP protection
output short circuit protection
N
•
•
•
•
•
•
•
•
•
output
voltage
output
current
output
power
ripple
& noise1
HϒFLHQF\2
range
(Vdc)
(Vdc)
min
(A)
max
(A)
max
(W)
max
(mVp-p)
W\S
(%)
AE40-UW-S12*
200~1500
12
0
3.33
40
300
76
AE40-UW-S15
200~1500
AE40-UW-S24*
200~1500
15
0
2.67
40
300
78
24
0
1.67
40
300
80
TI
input
voltage
1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF electrolytic and 1 µF ceramic capacitors on the output.
2. Measured at 800 Vdc input voltage, full load.
$OOVSHFL¿FDWLRQVDUHPHDVXUHGDW7D &KXPLGLW\QRPLQDOLQSXWYROWDJHDQGUDWHGRXWSXWORDGXQOHVVRWKHUZLVHVSHFL¿HG
4. * Discontinued model.
O
PART NUMBER KEY
N
Notes:
Output Voltage
Base Number
D
IS
C
AE40-UW - SXX
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 2 of 7
INPUT
parameter
conditions/description
min
under voltage shutdown
shut-down range
turn-on range
current
at 200 Vdc
at 800 Vdc
at 1500 Vdc
inrush current
at 200 Vdc
at 800 Vdc
at 1500 Vdc
input fuse
4 A / 1500 Vdc (external)
max
units
200
W\S
1500
Vdc
170
180
185
195
Vdc
Vdc
320
80
42
mA
mA
mA
ED
operating input voltage
30
80
150
conditions/description
maximum capacitive load
12 Vdc output model
15 Vdc output model
24 Vdc output model
min
N
parameter
U
OUTPUT
voltage accuracy
W\S
A
A
A
max
units
3,000
1,500
680
Nj)
Nj)
Nj)
±2
%
from low line to high line, full load
±1
%
load regulation
from 0% to full load
±1
%
delay time
IURP9LQ 9WRRIUDWHGRXSWXWYROWDJH
switching frequency
WHPSHUDWXUHFRHϒFLHQW
at full load
N
PROTECTIONS
TI
line regulation
parameter
conditions/description
over voltage protection
12 Vdc, 15 Vdc output models
24 Vdc output model
automatic recovery
O
over current protection
short circuit protection
min
2
s
65
kHz
±0.02
%/°C
W\S
120
max
units
20
30
Vdc
Vdc
320
%
max
units
continuous, automatic recovery
SAFETY AND COMPLIANCE
conditions/description
min
C
parameter
W\S
input to output for 1 minute
4,000
safety approvals
CSA, EN 62109, UL 1741
conducted emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
radiated emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
ESD
IEC/EN61000-4-2, contact ± 6kV/air ± 8kV, class B
radiated immunity
IEC/EN61000-4-3, 10V/m, class A
()7EXUVW
IEC/EN61000-4-4, ± 2kV, class B (external circuit required, see Figure 2)
surge
IEC/EN61000-4-5, line-line ± 1kV, class B (external circuit required, see Figure 2)
conducted immunity
IEC/EN61000-4-6, 10 Vr.m.s, class A
PDJQHWLF¿HOGLPPXQLW\
IEC/EN61000-4-8, 10 A/m, class A
07%)
as per MIL-HDBK-217F, 25°C
RoHS
yes
Vac
D
IS
isolation voltage
300,000
cui.com
hours
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
70
°C
-40
85
°C
95
%
5000
m
storage humidity
non-condensing
altitude
see derating curves
ED
storage temperature
W\S
SOLDERABILITY
parameter
conditions/description
min
W\S
max
units
hand soldering
for 3~5 seconds
350
360
370
°C
wave soldering
for 5~10 seconds
255
260
265
°C
max
units
U
MECHANICAL
conditions/description
dimensions
125.00 x 75.00 x 40.00 [4.921 x 2.953 x 1.575 inch]
case material
EODFNÀDPHUHWDUGDQWKHDWSURRISODVWLF8/9
weight
units: mm [inch]
tolerance: ±0.50[±0.020]
pin diameter tolerance: ±0.10[±0.004]
pin height tolerance: ±1.50[±0.059]
1
-Vin
2
+Vin
NC
4
-Vout
5
C
3
O
3,1&211(&7,216
Function
410
N
In high vibration environments, this series
should be mounted with screws.
tightening torque: max 0.4 N*m
W\S
TI
MECHANICAL DRAWING
PIN
min
N
parameter
+Vout
D
IS
1& QRFRQQHFWLRQ
Recommended PCB Layout
7RS9LHZ
cui.com
mm
g
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 4 of 7
C
O
N
TI
N
U
ED
DERATING CURVES
D
IS
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 5 of 7
D
IS
C
O
N
TI
N
U
ED
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 6 of 7
APPLICATION CIRCUIT
Fuse
4 A / 1500 Vdc
4 A / 1500 Vdc
24
4 A / 1500 Vdc
1
C2
Nj)
796
120
SMBJ20A
1
120
SMBJ20A
1
68
SMBJ30A
N
TI
12
15
C1
Nj)
N
Vout
(Vdc)
U
Table 1
ED
Figure 1
O
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
C
Recommended External Circuit Components
IS
FUSE
4 A/1500 Vdc
C7, C8, C9, C10
104K/275 Vac
C3, C4, C5, C6
47 µF/450 Vdc
R1, R2, R3, R4
0:
LDM
330 µH/1 A
LCM
7 mH/1 A
D
1RWH6HHDOVR7DEOH
1RWHV
&LVDFHUDPLFFDSDFLWRUXVHGWR¿OWHUKLJKIUHTXHQF\QRLVH
2. C2 is electrolytic and is recommended to be high frequency and low resistance. For capacitance and current of the capacitor, refer to the datasheet provided by the
manufacturer. Capacitance withstand voltage derating should be 80% or above.
cui.com
Additional Resources:
Product Page
CUI Inc Ϳ SERIES: AE40-UW Ϳ DESCRIPTION: DC-DC CONVERTER
date 11/11/2022 Ϳ page 7 of 7
REVISION HISTORY
description
date
09/13/2017
1.0
initial release
1.01
updated datasheet
1.02
added UL safety approval
1.03
changed external input fuse recommendation
ED
rev.
03/05/2018
02/26/2019
07/24/2019
company logo updated
1.05
GHUDWLQJFXUYHVHϒFLHQF\FXUYHVDQGFLUFXLW¿JXUHVXSGDWHG
08/31/2021
04/12/2021
1.06
discontinued models AE40-UW-S12 & AE40-UW-S12
11/11/2022
U
1.04
D
IS
C
O
N
TI
N
7KHUHYLVLRQKLVWRU\SURYLGHGLVIRULQIRUPDWLRQDOSXUSRVHVRQO\DQGLVEHOLHYHGWREHDFFXUDWH
Headquarters
20050 SW 112th Ave.
7XDODWLQ25
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
&8,RϑHUVDWZR\HDUOLPLWHGZDUUDQW\&RPSOHWHZDUUDQW\LQIRUPDWLRQLVOLVWHGRQRXUZHEVLWH
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
OLIHVXSSRUWGHYLFHRUV\VWHPZKRVHIDLOXUHWRSHUIRUPFDQEHUHDVRQDEO\H[SHFWHGWRFDXVHWKHIDLOXUHRIWKHOLIHVXSSRUWGHYLFHRUV\VWHPRUWRDϑHFWLWVVDIHW\RUHϑHFWLYHQHVV