SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
5 watts
high operating temp -40 to +70°C
4,000 Vac isolation
extra wide input voltage 10:1
input voltage up to 1 kVdc
OVP protection
output short circuit protection
chassis mounted
EN 62109 approved
MODEL
AE5-EW-S5-T
Notes:
input
voltage
output
voltage
output
current
range
(Vdc)
(Vdc)
min
(A)
100~1000
5
0
output
power
ripple
& noise1
efficiency2
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
1.0
5
200
72
1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF electrolytic and 1 µF ceramic capacitors on the output.
2. Measured at 200 Vdc input voltage, full load.
3. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
AE5-EW - SXX - T
Base Number
Output Voltage
cui.com
Mounting Style:
T = Chassis mount
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
date 07/20/2021 │ page 2 of 6
INPUT
parameter
conditions/description
min
operating input voltage
typ
100
current
at 200 Vdc
at 600 Vdc
at 1000 Vdc
inrush current
at 200 Vdc
at 600 Vdc
at 1000 Vdc
input fuse
1 A / 1000 Vdc (external)
max
units
1000
Vdc
38
15
10
mA
mA
mA
7
20
30
A
A
A
OUTPUT
parameter
conditions/description
min
typ
maximum capacitive load
voltage accuracy
max
units
6,000
μF
±1
±2
%
line regulation
from low line to high line, full load
±0.5
±1
%
load regulation
from 0% to full load
±0.5
±1
%
delay time
from Vin = 0 V to 90% of rated ouptut voltage
1
s
switching frequency
temperature coefficient
75
at full load
±0.02
kHz
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
over current protection
automatic recovery
short circuit protection
continuous, automatic recovery
max
units
7.5
Vdc
110
%
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
input to output for 1 minute
safety approvals
EN 62109
conducted emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
radiated emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
ESD
IEC/EN61000-4-2, contact ± 6kV/air ± 8kV, class B
radiated immunity
IEC/EN61000-4-3, 10V/m, class A
EFT/burst
IEC/EN61000-4-4, ± 4kV, class B (external circuit required, see Figure 2)
surge
IEC/EN61000-4-5, ± 2kV, class B (external circuit required, see Figure 2)
conducted immunity
IEC/EN61000-4-6, 10 Vr.m.s, class A
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
2011/65/EU
4,000
300,000
cui.com
max
units
Vac
hours
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
date 07/20/2021 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
70
°C
-40
105
°C
95
%
2000
m
max
units
storage temperature
storage humidity
typ
non-condensing
altitude
MECHANICAL
parameter
conditions/description
min
dimensions
96.10 x 54.00 x 32.00 [3.783 x 2.126 x 1.260 inch]
case material
black flame-retardant heat-proof plastic (UL94V-0)
weight
typ
mm
150
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±0.50[±0.020]
wire range: 24~12 AWG
tightening torque: max 0.4 N*m
PIN CONNECTIONS
PIN
Function
1
-Vin
2
NC
3
+Vin
4
+Vout
5
NC
6
NC
7
-Vout
NC=no connection
cui.com
g
Additional Resources:
Product Page
CUI Inc │ SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
|
3D Model
date 07/20/2021 │ page 4 of 6
DERATING CURVES
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
date 07/20/2021 │ page 5 of 6
APPLICATION CIRCUIT
Figure 1
Table 1
Vout
(Vdc)
Fuse
MOV
NTC
C1
(µF)
C2
(µF)
TVS
5
1 A / 1000 Vdc
S14K880
10D-11
1
220
SMBJ7.0A
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
FUSE
1 A/1000 Vdc
MOV
S14K880
C3, C4, C5, C6
47 µF/400 Vdc
R1, R2, R3, R4
1 MΩ/2 W
NTC
10D-11
LDM
4.7 mH/0.38 A
LCM
10 mH
Note: See also Table 1.
Notes:
1. C1 is a ceramic capacitor used to filter high frequency noise.
2. C2 is electrolytic and is recommended to be high frequency and low resistance. For capacitance and current of the capacitor, refer to the datasheet provided by the
manufacturer. Capacitance withstand voltage derating should be 80% or above.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: AE5-EW-T │ DESCRIPTION: DC-DC CONVERTER
date 07/20/2021 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
09/13/2017
1.01
company logo updated
04/12/2021
1.02
derating curves and circuit figures updated
07/20/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“AE5-EW-S5-T”相匹配的价格&库存,您可以联系我们找货
免费人工找货