page 1 of 6
SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
FEATURES
• 120 x 120 mm frame
• high fan speed for greater air flow
• dual ball bearing construction
• auto restart protection standard on all models
MODEL
input
voltage
rated
(Vdc)
input
current
range
(Vdc)
typ
(A)
input power
rated speed
air
flow1
static pressure2
max
(A)
max
(W)
noise
typ
(RPM)
(CFM)
(inch H2O)
max
(dBA)
CFM-A225-13*
12
6~13.8
0.59
0.79
9.48
4,100
126.89
0.49
53.5
CFM-A225-23*
24
16~27.6
0.31
0.39
9.36
4,100
126.89
0.49
53.5
CFM-A225-43*
48
30~55.2
0.17
0.23
11.04
4,100
126.89
0.49
53.5
CFM-A238-13*
12
6~13.8
1.40
1.75
21
4,600
200.9
0.78
61.5
CFM-A238-23*
24
16~27.6
0.77
0.88
21.12
4,600
200.9
0.78
61.5
CFM-A238-43*
48
30~55.2
0.36
0.48
23.04
4,600
200.9
0.78
61.5
Notes:
1. At 0 inch H20 static pressure.
2. At 0 CFM airflow.
*. Discontinued CFM-A225-13-10, CFM-A225-13-11, CFM-A225-13-20, CFM-A225-23-11, CFM-A225-23-22, CFM-A225-43-11, CFM-A225-43-20, CFM-A225-43-22,
CFM-A238-13-11, CFM-A238-23-11, CFM-A238-23-20, CFM-A238-23-22, and CFM-A238-43-20 models.
PART NUMBER KEY
CFM-A2 XX - X 3 - XX - CXX
Base Number
Depth
25 = 25 mm
38 = 38 mm
Reserved for Custom
Configurations
Input Voltage
1 = 12 Vdc
2 = 24 Vdc
4 = 48 Vdc
cuidevices.com
Fan Signals
10 = no signals
11 = rotation detector signal
20 = tachometer signal
22 = tachometer signal / PWM control signal
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
date 08/12/2022 | page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
12 Vdc input models
24 Vdc input models
48 Vdc input models
6
16
30
12
24
48
13.8
27.6
55.2
Vdc
Vdc
Vdc
current
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
0.59
0.31
0.17
1.40
0.77
0.36
0.79
0.39
0.23
1.75
0.88
0.48
A
A
A
A
A
A
power
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
7.08
7.44
8.16
16.80
18.48
17.28
9.48
9.36
11.04
21
21.12
23.04
W
W
W
W
W
W
starting voltage
at 25°C
12 Vdc input models
24 Vdc input models
48 Vdc input models
6
12
24
Vdc
Vdc
Vdc
PERFORMANCE
parameter
conditions/description
min
typ
max
units
rated speed
at 25°C, after 10 minutes
CFM-A225 models
CFM-A238 models
3,690
4,140
4,100
4,600
4,510
5,060
RPM
RPM
air flow
at 0 inch H2O, see performance curves
CFM-A225 models
CFM-A238 models
static pressure
noise
126.89
200.9
CFM
CFM
at 0 CFM, see performance curves
CFM-A225 models
CFM-A238 models
0.49
0.78
inch H2O
inch H2O
at 1 m
CFM-A225 models
CFM-A238 models
51.5
59.5
53.5
61.5
dBA
dBA
min
typ
max
units
min
typ
max
units
PROTECTIONS / SIGNALS1
parameter
conditions/description
auto restart protection
available on all models
rotation detector
available on “11” models
tachometer signal
available on “20” and “22” models
PWM control signal
available on “22” models
Notes:
1. See application notes for details.
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance of frame
at 500 Vdc between frame and positive terminal
dielectric strength
at 500 Vac, 60 Hz, 1 minute between frame and positive
terminal
safety approvals
UL/cUL 507, TUV (EN 62368-1)
EMI/EMC
EN 55022:2010+AC:2011 Class B, EN 61000-3-2:2014, EN
61000-3-3:2013, EN 55024:2010
life expectancy
at 45°C, 15~65% RH
RoHS
yes
10
MΩ
5
70,000
cuidevices.com
mA
hours
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
date 08/12/2022 | page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
typ
max
units
70
°C
-10
storage temperature
-40
70
°C
operating humidity
non-condensing
5
90
%
storage humidity
non-condensing
5
95
%
PERFORMANCE CURVES
0.50
0.40
CFM-A238
(mm H2O)
(Inch H2O)
CFM-A225
14.00
0.98
12.00
.
.
10.00
0.30
0.20
.
8.00
6.00
10.
4.00
0.10
0.00
.
2.00
0.00
0.00
0.00
50.00
100.00
150.00 (CFM)
0.
0.
(CMM)
0.00
0.74
1.49
2.23
2.98
3.72
0.00
cuidevices.com
.
100.
.
.
.
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
date 08/12/2022 | page 4 of 6
MECHANICAL
parameter
conditions/description
motor
4 pole DC brushless
min
bearing system
ball bearing
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CFM-A225 models 120 x 120 x 25.4
CFM-A238 models 120 x 120 x 38
material
PBT (UL94V-0)
weight
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
units: mm [inch]
CFM-A225
wire: UL 1007, 24 AWG
WIRE CONNECTIONS
Function
Red
+Vin
Black
-Vin
Yellow1
FG Signal
White
RD Signal
Blue1
PWM
1
ōŢţŦŭ
CFM-A238
wire: UL 1007, 24 AWG
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
1
Yellow
FG Signal
White1
RD Signal
Blue
PWM
1
Note:
ōŢţŦŭ
1. Wires only present on versions with output signals.
cuidevices.com
max
units
mm
mm
190.0
189.8
190.6
297.0
283.7
283.2
MECHANICAL DRAWING
Wire Color
typ
g
g
g
g
g
g
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
date 08/12/2022 | page 5 of 6
APPLICATION NOTES
Auto Restart Protection/Current Limit Protection
When the fan motor is locked, the device will cut off the drive current within two to six seconds and restart automatically after a few
seconds. If the lock situation is continued, the device will work on a repeated cycle of cut-off and restart until the lock is released. (See
Figure 1 below).
Figure 1 Current Limit Protection
Lock Sensor/Rotation Detector
Lock Sensor is used to detect if the fan motor is operating or stopped. Alarm High: the output will be logical low when fan is operating and
be logical high when fan motor is locked. (See Figures 2~3 below).
Figure 3 RD Signal Output Circuit:
Open Collector
Figure 2 Alarm High
Output Waveform
Ic=5mA max
Pulse Sensor/Tachometer Signal/FG
Pulse Sensor is for detecting the rotational speed of the fan motor. At locked rotor condition, the signal stops cycling and the output is fixed
at VoH or VoL (See Figures 4~5 below).
Figure 4 Output Waveform
Figure 5 FG Signal Output Circuit:
Open Collector
Ic=10mA max
PMW Control Signal
A speed control lead can be provided that will accept a PWM signal from the customer circuit to vary the speed of the fan. The change in
speed is linear by changing the Duty-Cycle of the PWM. Open collector type and pull-up voltage is changed by maximum operating voltage
and sink current by consuming current. (See Figure 6 below).
Figure 6 Duty Cycle
Vs=4~5 V
cuidevices.com
Additional Resources:
Product Page
|
3D Model
CUI DEVICES | SERIES: CFM-120 | DESCRIPTION: DC AXIAL FAN
date 08/12/2022 | page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
08/15/2016
1.01
updated datasheet
07/27/2017
1.02
updated to be certified to EN 62368-1 safety standard
07/09/2019
1.03
brand update
02/07/2020
1.04
discontinued CFM-A225-23-22 and CFM-A238-23-22 models
03/31/2022
1.05
discontinued CFM-A225-13-10, CFM-A225-13-11, CFM-A225-13-20,
CFM-A225-23-11, CFM-A225-43-11, CFM-A225-43-20,
CFM-A225-43-22, CFM-A238-13-11, CFM-A238-23-11,
CFM-A238-23-20, and CFM-A238-43-20 models
04/26/2022
logo, datasheet style update
08/12/2022
1.06
The revision history provided is for informational purposes only and is believed to be accurate.
CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate
and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may
result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A
critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
cuidevices.com