Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
08/05/2022
page 1 of 4
MODEL: CMA-4544PF-W | DESCRIPTION: ELECTRET CONDENSER MICROPHONE
SPECIFICATIONS
parameter
conditions/description
directivity
omnidirectional
sensitivity (S)
f = 1 kHz, 1 Pa, 0 dB = 1 V/1 Pa
min
typ
max
units
-46
-44
-42
dB
3
10
Vdc
operating voltage
output impedance (Zout)
f = 1 kHz, 1 Pa
2.2
sensitivity reduction (∆S-Vs)
f = 1 kHz, 1 Pa, Vs = 3.0 to 2.0 Vdc
-3
frequency (f)
20
current consumption (IDSS)
Vs = 3.0 Vdc, RL = 2.2 KΩ
signal to noise ratio (S/N)
f = 1 kHz, 1 Pa, A-weighted
KΩ
dB
20,000
0.5
Hz
mA
60
dBA
operating temperature
-20
70
°C
storage temperature
-20
70
°C
0.8
g
dimension
ø9.7 x 4.5 mm
weight
material
Al
terminal
pin type (hand soldering only)
RoHS
yes
Note:
We use the “Pascal (Pa)” indication of sensitivity as per the recomendation of I.E.C. (International Electrotechnical Commission). The sensitivity of “Pa” will increase 20dB
compared to the “ubar” indication. Example: -60dB (0dB = 1V/ubar) = -40dB (1V/Pa)
MECHANICAL DRAWING
MEASUREMENT CIRCUIT
unit: mm
RL = 2.2 KΩ
ŇņŕġŊŮűŦťŢůŤŦ
ŤŰůŷŦųŵŦų
ŕŦųŮįIJ
ńľIJŶŇ
œō
ņįńįŎį
ŶůŪŵ
ŔũŪŦŭťġńŢŴŦ
Schematic Diagram
cuidevices.com
ŐŶŵűŶŵ
ĬŗŴ
ŕŦųŮįij
ĮňųŰŶůť
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI DEVICES | MODEL: CMA-4544PF-W | DESCRIPTION: ELECTRET CONDENSER MICROPHONE
date 08/05/2022 | page 2 of 4
FREQUENCY RESPONSE CURVE
ijı
IJı
ĩťŃĪ ı
ĮIJı
Įijı
ĮĴı
ijı
Ķı
IJıı
ijıı
Ķıı
IJŌ ijŌ
ĶŌ
IJıŌ
ijıŌ
ĩʼnŻĪ
1.000V/PA
MECHANICAL CHARACTERISTICS
item
test condition
evaluation standard
soldering heat resistance
Soldering iron of +270 ±5°C should be placed on the
terminal for 2 ±0.5 seconds.
No interference in operation.
terminal mechanical strength
Apply to the terminal 4.9 N (0.5 kg) for 30 seconds
No damage or cutting off.
vibration test
The part should be measured after a vibration amplitude of 1.5 mm
with 10~55 Hz band of vibration frequency to each of the 3 perpendicular directions for 2 hours.
drop test
The part without packaging is subjected to 3 drops on each axis
from the height of 1 m onto a 20 mm thick wooden board.
After any tests, the sensitivity should be within
±3 dB of the initial sensitivity.
ENVIRONMENT TEST
item
test condition
high temperature test
After being placed in a chamber at +70°C for 72 hours.
evaluation standard
low temperature test
After being placed in a chamber at -20°C for 72 hours.
thermal shock
After being placed in a chamber at +40°C and 90 ±5% RH for 240
hours.
The part will be subjected to 10 cycles. One cycle will consist of:
After any tests and 6 hours of
conditioning at +25°C, the
sensitivity should be within ±3 dB of the initial
sensitivity.
temperature cycle test
TEST CONDITIONS
standard test conditions
a) Temperature: +5 ~ +35°C
b) Humidity: 45 ~ 85%
c) Pressure: 860 ~ 1060 mbar
judgement test conditions
a) Temperature: +25 ±2°C
b) Humidity: 60 ~ 70%
c) Pressure: 860 ~ 1060 mbar
cuidevices.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI DEVICES | MODEL: CMA-4544PF-W | DESCRIPTION: ELECTRET CONDENSER MICROPHONE
PACKAGING
cuidevices.com
date 08/05/2022 | page 3 of 4
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI DEVICES | MODEL: CMA-4544PF-W | DESCRIPTION: ELECTRET CONDENSER MICROPHONE
date 08/05/2022 | page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
06/01/2008
1.01
new template applied, updated drawing
09/24/2013
1.02
brand update
01/17/2020
logo, datasheet style update
08/05/2022
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate
and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may
result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A
critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
cuidevices.com
很抱歉,暂时无法提供与“CMA-4544PF-W”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+5.255631+0.65540
- 100+3.53396100+0.44070
- 国内价格 香港价格
- 1+6.690681+0.83436
- 10+5.2065910+0.64929
- 25+4.7329125+0.59022
- 50+4.4069050+0.54956
- 100+4.10561100+0.51199
- 300+3.67533300+0.45833
- 500+3.49326500+0.43563
- 1000+3.263141000+0.40693
- 5000+2.794345000+0.34847