Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
09/21/2021
page
1 of 6
SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
up to 1 A current output
pin compatible with LM78XX linear regulators
non-isolated switching regulator
wide input voltage range
efficiency up to 91%
low ripple and noise
short circuit protection
ultra-compact SIP3 package
low profile
-40°C to +85°C temperature range
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency2
typ
(Vdc)
range
(Vdc)
(Vdc)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
P78A03-1000
24
7~28
3.3
1000
3.3
120
87
P78A05-1000
24
8~28
5
1000
5
120
91
Notes:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with a 0.1 µF multilayer low ESR ceramic capacitor.
2. At min Vin.
3. All specifications measured at: Ta=25°C, nominal input voltage, rated output load, and after warm up unless otherwise specified.
PART NUMBER KEY
P78A XX - 1000
Base Number
Output Voltage
cui.com
Output Current
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
date 09/21/2021 │ page 2 of 6
INPUT
parameter
conditions/description
operating input voltage
3.3 Vdc model
5 Vdc model
no load input current
Vin = 24 Vdc
min
typ
max
units
7
8
24
24
28
28
Vdc
Vdc
1.5
mA
OUTPUT
parameter
conditions/description
min
typ
maximum capacitive load
1
line regulation
measured from low to high line, full load
load regulation
measured from 10~100% load, typical Vin
voltage accuracy
switching frequency
Note:
±3
Vin = 12 Vdc
max
units
220
μF
±1
%
±1.5
%
±5
%
330
kHz
1. Maximum capacitive load is tested at nominal input voltage and full load.
PROTECTIONS
parameter
conditions/description
min
over current protection
output shut down, auto recovery
short circuit protection
output shut down, auto recovery
typ
max
units
200
%
SAFETY AND COMPLIANCE
parameter
conditions/description
MTBF
as per MIL-HDBK-217F, full load, 25 °C
min
RoHS
2011/65/EU
typ
max
3,875,000
units
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
operating humidity
typ
max
units
-40
85
°C
-55
125
°C
95
%
max
units
260
°C
non-condensing
SOLDERABILITY
parameter
conditions/description
wave soldering
see wave solder profile
Note:
min
2. The wave solder profile is measured on lead temperature.
3. Need to keep the solder parts internal temperature less than about 210°C.
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
date 09/21/2021 │ page 3 of 6
MECHANICAL
parameter
conditions/description
dimensions
11.6 x 8.5 x 10.4
min
case material
non-conductive black plastic (UL94V-0)
potting material
epoxy (UL94V-0)
typ
max
units
mm
weight
2
g
MECHANICAL DRAWING
units: mm
tolerance: XX.X=±0.50 mm
XX.XX=±0.25 mm
11.6
2
GND
3
+Vout
xxxx
xxxx
Marking
1 2 3
0.25
0.7 typ.
Ø1.00 +0.15/-0
2.54
+Vin
0.51
1
8.5
4.10
Function
2.0
PIN
10.4
PIN CONNECTIONS
2.54
3.21 5.08
Recommended PCB Layout
Top View
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 09/21/2021 │ page 4 of 6
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
date 09/21/2021 │ page 5 of 6
APPLICATION CIRCUIT
Figure 1
Table 1
Optional External
Components
Notes:
C1
10μF MLCC
C2
10μF MLCC
1. To protect the converter during power-up, use soft start power supply.
2. The converter cannot be used as a positive to negative converter.
PACKAGING
units: mm
Tube Size: 520 x 16.5 x 9.3 mm
QTY: 42 pcs
16.5±0.5
12.1±0.5
9.3±0.5
0.5±0.2
4.9±0.5
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: P78A-1000 │ DESCRIPTION: DC-DC CONVERTER
date 09/21/2021 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
05/16/2016
1.01
company logo updated
04/14/2021
1.02
derating curve, efficiency curves and application circuit updated
09/21/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“P78A05-1000”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+43.32896
- 5+42.64925
- 10+41.86079