Additional Resources:
Product Page
|
3D Model
date
06/02/2022
page
1 of 8
SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
up to 400 W continuous power
universal input (90~264 Vac)
active power factor correction
peak power of 700W for 500µs duration (single output models only)
built-in remote ON/OFF, power good, & fan fail alarm options
over voltage, short circuit, over current, and
over temperature protection
• efficiency up to 87%
MODEL
preset
output
voltage
customizable
output
range7
output
current
output
power
ripple
and noise8,9
efficiency
(Vdc)
(Vdc)
max
(forced air)
(A)
PCM-400-121,2
12
10~13.8
33.33
18.33
400
120
85
1,2
PCM-400-15
15
14~15.5
26.67
14.67
400
150
85
PCM-400-181,2
18
16~20
22.22
12.22
400
180
85
PCM-400-24
24
21~26
16.67
9.17
400
240
87
1,2
PCM-400-28
28
27~34
14.29
7.86
400
280
85
PCM-400-361,2
36
35~42
11.11
6.11
400
360
87
1,2
PCM-400-48
48
43~50
8.33
4.58
400
480
87
PCM-400-541,2
54
51~60
7.41
4.07
400
540
87
1,2
max
(convection)
(A)
max
(W)
max
(mVp-p)
typ
(%)
PCM-400-D05123,4,*
Vo1
Vo2
5
12
N/A
30
20.83
15
13.33
320
50
120
87
PCM-400-D05243,4,*
Vo1
Vo2
5
24
N/A
30
10.42
15
6.67
320
50
240
87
PCM-400-D05483,4,*
Vo1
Vo2
5
48
N/A
30
5.21
15
3.33
320
50
480
87
PCM-400-D12245,6
Vo1
Vo2
12
24
N/A
20.83
10.42
12.5
8.33
400
120
240
87
Notes:
1. For U-frame models, the maximum output power is 400W with a minimum of 27 CFM forced air, 220 W maximum with convection cooling.
2. For CNF models, the maximum output is 220 W with convection cooling.
3. For U-frame models, the total combined output power is 320W with a minimum of 27 CFM forced air, 180 W maximum with convection cooling.
4. For CNF models, the maximum output is 180 W with convection cooling.
5. For U-frame models, the total combined output power is 400W with a minimum of 27 CFM forced air, 200 W maximum with convection cooling.
6. For CNF models, the maximum output is 200 W with convection cooling.
7. Output can be custom set within range.
8. Measured at 10 kHz ~ 20 MHz bandwidth, with a 22 µF electrolytic and 0.1 µF ceramic capacitor on the output.
9. 1% minimum load is required to maintain ripple and regulation (10% for dual output models).
10. * Discontinued model.
PART NUMBER KEY
PCM-400 - X XX - XXX - X
Base Number
Output
“blank” = Single
D = Dual
Output Voltage
cui.com
Chassis
Input/Output Connectors
U = U-frame
“blank” = terminal block
CNF = enclosed
1 = header
CF = enclosed with top fan
CFS = enclosed with rear fan
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/02/2022
page 2 of 8
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at 90 Vac, full load
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
leakage current
at 120 Vac
at 240 Vac
power factor correction
at 230 Vac, full load
remote ON/OFF
designated as INH on Pin 4 of CN1, requires a low
signal to inhibit output
input fuse
T8 A/250 V on the input
max
units
264
Vac
63
Hz
8
A
35
70
A
A
300
500
μA
μA
max
units
0.9
OUTPUT
parameter
conditions/description
total regulation
single output models
dual output models
transient response
returns to within 1% in
很抱歉,暂时无法提供与“PCM-400-15-CFS”相匹配的价格&库存,您可以联系我们找货