Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
05/23/2023
page
1 of 8
SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
30W isolated output
1500 Vdc isolation
1 x 1 inch industry standard package
ultra-wide 4:1 input voltage range
EN62368 approved
wide temperature range: -40°C to +85°C
high efficiency up to 88%
input under-voltage protection, output short circuit, over-current,
over–voltage protection
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PDQE30-Q48-S5-D
48
18~75
5
0
6000
30
120
88
PDQE30-Q48-S12-D
48
18~75
12
0
2500
30
120
88
PDQE30-Q48-S15-D
48
18~75
15
0
2000
30
120
88
PDQE30-Q48-S24-D
48
18~75
24
0
1250
30
150
88
Note:
1. Ripple & noise testing condition at nominal input voltage and 5%-100% load, 20MHz bandwidth
PART NUMBER KEY
PDQE30 - QXX - SXX - D
Base Number
Input Voltage
Output Voltage
cui.com
Packaging Style
DIP
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 2 of 8
INPUT
parameter
conditions/description
input voltage
start-up voltage
nominal input voltage
surge voltage
nominal input voltage
filter
capacitance filter
current
nominal input voltage (full load/no load)
min
typ
max
units
18
48
75
Vdc
-0.7
under-voltage lockout
710/8
12
start-up time
nominal input voltage
CTRL1
module on - open or pulled high
module off - pulled low to GND
input current when off
3.5
0
parameter
conditions/description
min
line regulation
load regulation
Note:
18
Vdc
100
Vdc
735/15
mA
15.5
Vdc
10
mS
2
12
1.2
7
Vdc
Vdc
mA
typ
max
units
min to max Vin
±0.2
±0.5
%
5% ~ 100% load
±0.5
±1
%
±1
±3
%
1. CTRL is referenced to GND
OUTPUT
set-point accuracy
switching frequency
PWM mode
270
transient response
25% load step change
5V output
others
±3
±3
temperature coefficient
full load
adjustability
via trim pin
kHz
±8
±5
%
%
±0.03
%/°C
±10
%
PROTECTIONS
parameter
conditions/description
min
typ
max
units
over voltage protection
110
160
%Vo
over current protection
110
260
%Io
short circuit protection
continuous, self-recovery
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 3 of 8
SAFETY AND COMPLIANCE
parameter
conditions/description
min
isolation voltage
input-output electric strength test for 1 minute
1500
typ
isolation resistance
input-output insulation at 500 Vdc
1000
isolation capacitance
input-output capacitance at 100 KHz / 0.1 V
safety approvals
EN62368 approved
EMC
CISPR32/EN55032 Class B (see recommended circuit)
ESD
IEC/EN61000-4-2, Contact ±6K, perf. Criteria B
radiated immunity
IEC/EN61000-4-3, 10 v/m, perf. Criteria B
EFT/burst
IEC/EN61000-4-4, ±2KV, perf. Criteria B (see recommended circuit)
surge
IEC/EN61000-4-5, line to line ±2KV, perf. Criteria B (see recommended circuit)
conducted immunity
IEC/EN61000-4-6 3 Vrms, perf. Criteria B
RoHS
yes
MTBF
MIL-HDBK-217F @ 25°C
max
units
Vdc
MΩ
2000
pF
1000
kHours
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
operating temperature
-40
85
°C
storage temperature
-55
125
°C
5
95
%
max
units
300
°C
humidity
non-condensing
SOLDERABILITY
parameter
conditions/description
min
hand soldering
1.5 mm from case for 10 seconds
cui.com
typ
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 05/23/2023 │ page 4 of 8
DERATING CURVES
Figure 1
Note:
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 5 of 8
MECHANICAL
parameter
conditions/description
dimensions
25.40 × 25.40 × 11.70 mm
case material
aluminum alloy
min
18.4
MECHANICAL DRAWING
units: inches [mm]
tolerance: ± 0.50 [±0.020]
PIN CONNECTIONS
FUNCTION
1
Ctrl
2
GND
3
Vin
4
Vo
5
Trim
6
0V
max
units
inch
weight
PIN
typ
cui.com
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 6 of 8
TYPICAL APPLICATION CIRCUIT
Figure 2
Vout (Vdc)
5/12/15
24
EMC COMPLIANCE CIRCUITS
Figure 3
Note: We use Part ① in Fig. 3 for Immunity tests and Part ➁ for
Emissions test. Selecting based on needs.
Model
Vin: 48 V
FUSE
Choose according to actual input current
C0, C4
470µF/100V
C1
10µF/100V
LDM1
22uH/3A
C2
22uF/100V
LCM1
1.4mH/3A
C3
22uF/100V
C5
Refer to the Cout Fig.2
CY1, CY2
1nF/2KV
cui.com
Cin (µF)
100
Cout (µF)
100
47
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 7 of 8
TRIM FUNCTION FOR OUTPUT VOLTAGE ADJUSTMENT
Trim resistor connection (dashed line shows internal resistor network).
VNOM
RTOP
RBOTTOM
RO
VREF
(Vdc)
(kΩ)
(kΩ)
(kΩ)
(V)
5
8.832
2.87
10
1.24
12
11.00
2.87
8.2
2.5
15
14.40
2.87
10
2.5
24
24.87
2.87
7.5
2.5
Note:
Value for RTOP, RBOTTOM, RO, and VREF refer to Table 4 (fixed internal values).
RTRIM: Trim resistance
a: User-defined parameter, no actual meanings
VNOM: Nominal output voltage
VOUT: Target output voltage
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDQE30-D │ DESCRIPTION: DC-DC CONVERTER
date 05/23/2023 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
03/28/2020
1.01
derating curve and circuit figures updated
08/24/2021
1.02
adjustability limits added
03/14/2022
output voltage trimming updated
05/23/2023
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PDQE30-Q48-S24-D”相匹配的价格&库存,您可以联系我们找货
免费人工找货