0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PDRB-100-48

PDRB-100-48

  • 厂商:

    CUI

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 48V 101W

  • 数据手册
  • 价格&库存
PDRB-100-48 数据手册
Additional Resources: Product Page | 3D Model date 04/11/2023 page 1 of 6 SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY FEATURES • • • • • • • • universal input range (85 ~ 264 Vac) IEC/EN/UL 62368 certified designed to meet 61558 system requirements over Voltage Category (OVC) III design over voltage, over current, and short circuit protections 4kVac isolation input to output withstand up to 300 Vac input surge events Class B emissions MODEL output1 voltage output current output power ripple and noise2 efficiency3 (Vdc) range (Vdc) max (A) max (W) max (mVp-p) typ (%) PDRB-100-12 12 12.0 ~ 13.8 7.5 90.0 120 88 PDRB-100-15 15 13.5 ~ 18.0 6.5 97.5 120 89 PDRB-100-24 24 21.6 ~ 29.0 4.2 100.8 150 90 PDRB-100-48 48 43.2 ~ 55.2 2.1 100.8 240 90 Notes: 1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage and output power do not exceed stated limits. 2. At full load, nominal input, 20 MHz bandwidth oscilloscope. 3. At 230 Vac input. PART NUMBER KEY PDRB-100 - XX Base Number Output Voltage cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY date 04/11/2023 │ page 2 of 6 INPUT parameter conditions/description min max units input voltage ac input dc input 85 120 264 370 Vac Vdc 47 63 Hz 3.0 1.6 A A frequency current at 115 Vac at 230 Vac inrush current at 115 Vac at 230 Vac leakage current at 240 Vac typ 35 70 A A 0.5 mA max units 10,000 6,400 2,500 1,100 µF µF µF µF OUTPUT parameter conditions/description capacitive load 12 15 24 48 initial set point accuracy 0% ~ 100% load line regulation load regulation Vdc Vdc Vdc Vdc output output output output min typ models models models models ±2 % at rated load ±0.5 % at 230 Vac ±1.5 % at 230 Vac 30 start-up time hold-up time 3 switching frequency temperature coefficient no load power consumption s ms 65 kHz ±0.03 %/°C at 230 Vac 12 Vdc, 15 Vdc output models 24 Vdc output models 48 Vdc output models 0.3 0.35 0.4 W W max units 20 25 35 60 Vdc Vdc Vdc Vdc 200 % PROTECTIONS parameter conditions/description over voltage protection 12 15 24 48 over current protection auto recovery short circuit protection continuous, auto recovery, hiccup Vdc Vdc Vdc Vdc output output output output min models models models models 110 cui.com typ Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY date 04/11/2023 │ page 3 of 6 SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output 5 mA for 1 minute min safety approvals certified to 62368: IEC, EN, UL/cUL safety class Class II conducted emissions CISPR32/EN55032 CLASS B radiated emissions CISPR32/EN55032 CLASS B ESD IEC/EN61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A radiated immunity IEC/EN61000-4-3 10V/m perf. Criteria A EFT/burst IEC/EN61000-4-4 ±4KV perf. Criteria A surge IEC/EN61000-4-5 line to line ±2KV perf. Criteria A conducted immunity IEC/EN61000-4-6 10Vr.m.s perf. Criteria A voltage dips and interruption IEC/EN61000-4-11 0%, 70% perf. Criteria A MTBF as per MIL-HDBK-217F at 25°C RoHS yes typ max 4,000 units Vac 300,000 hours ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 70 °C -40 85 °C 0 95 % 2,000 m storage temperature storage humidity non-condensing altitude cui.com typ Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY date 04/11/2023 │ page 4 of 6 MECHANICAL parameter conditions/description dimensions 70.00 x 92.66 x 58.00 min material plastic, heat-resistant (UL94V-0) 235 cooling natural convection MECHANICAL DRAWING units: mm [inch] ADJ: built-in trimpot wire range: 24-12 AWG tightening torque: Max 0.4 N·m mounting rail: TS35 general tolerances: ±1.0 [±0.039] TERMINAL CONNECTIONS Function 1 AC (L) 2 AC (N) 3 +Vo 4 +Vo 5 -Vo 6 -Vo max units mm weight TERMINAL typ cui.com g Additional Resources: Product Page CUI Inc │ SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY DERATING CURVE EFFICIENCY CURVES cui.com | 3D Model date 04/11/2023 │ page 5 of 6 Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PDRB-100 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY date 04/11/2023 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 11/25/2020 1.01 derating and efficiency curves updated 02/17/2022 1.02 UKCA mark added 04/11/2023 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PDRB-100-48 价格&库存

很抱歉,暂时无法提供与“PDRB-100-48”相匹配的价格&库存,您可以联系我们找货

免费人工找货
PDRB-100-48
    •  国内价格
    • 1+296.19317

    库存:11