SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
universal input range (85 ~ 264 Vac)
IEC/EN/UL 62368 certified
designed to meet 61558 system requirements
over Voltage Category (OVC) III design
over voltage, over current, and short circuit protections
4kVac isolation input to output
withstand up to 300 Vac input surge events
Class B emissions
MODEL
PDRB-30-5
output1
voltage
output
current
output
power
ripple
and noise2
efficiency3
(Vdc)
range
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
5
4.9 ~ 5.5
3.0
15
80
82
PDRB-30-12
12
10.8 ~ 13.8
2.0
24
120
88
PDRB-30-15
15
13.5 ~ 18.0
2.0
30
120
89
PDRB-30-24
24
21.6 ~ 29.0
1.5
36
150
88
PDRB-30-48
48
43.2 ~ 55.2
0.75
36
240
90
Notes:
1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output
voltage and output power do not exceed stated limits.
2. At full load, nominal input, 20 MHz bandwidth oscilloscope.
3. At 230 Vac input.
PART NUMBER KEY
PDRB-30 - XX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 05/26/2022 │ page 2 of 6
INPUT
parameter
conditions/description
min
max
units
input voltage
ac input
dc input
85
120
264
370
Vac
Vdc
47
63
Hz
0.9
0.5
A
A
frequency
current
at 115 Vac
at 230 Vac
inrush current
at 115 Vac
at 230 Vac
leakage current
at 264 Vac
typ
25
45
A
A
0.25
mA
max
units
12,000
6,000
5,000
1,400
600
µF
µF
µF
µF
µF
OUTPUT
parameter
conditions/description
capacitive load
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
initial set point accuracy
0% ~ 100% load
line regulation
load regulation
min
typ
±2
%
at rated load
±0.5
%
at 230 Vac
±1.5
%
at 115 Vac
at 230 Vac
12
60
ms
ms
65
kHz
±0.02
%/°C
start-up time
hold-up time
3
switching frequency
temperature coefficient
no load power consumption
at 230 Vac
5 Vdc, 12 Vdc, 15 Vdc output models
24 Vdc output model
48 Vdc output model
s
0.3
0.8
0.4
W
W
W
max
units
7.5
16
20
36
60
Vdc
Vdc
Vdc
Vdc
Vdc
PROTECTIONS
parameter
conditions/description
min
over voltage protection
clamp or hiccup
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
over current protection
auto recovery
short circuit protection
continuous, auto recovery, hiccup
120
cui.com
typ
%
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 05/26/2022 │ page 3 of 6
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output 5 mA for 1 minute
safety approvals
certified to 62368: IEC, EN, UL/cUL
safety class
Class II
conducted emissions
CISPR32/EN55032 CLASS B
radiated emissions
CISPR32/EN55032 CLASS B
ESD
IEC/EN61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A
radiated immunity
IEC/EN61000-4-3 10V/m perf. Criteria A
EFT/burst
IEC/EN61000-4-4 ±2KV perf. Criteria A
surge
IEC/EN61000-4-5 line to line ±2KV perf. Criteria A
conducted immunity
IEC/EN61000-4-6 10Vr.m.s perf. Criteria A
voltage dips and interruption
IEC/EN61000-4-11 0%, 70% perf. Criteria A
MTBF
as per MIL-HDBK-217F at 25°C
RoHS
yes
typ
max
4,000
units
Vac
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
70
°C
-40
85
°C
0
95
%
2,000
m
storage temperature
storage humidity
non-condensing
altitude
cui.com
typ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 05/26/2022 │ page 4 of 6
MECHANICAL
parameter
conditions/description
dimensions
92.66 x 35.00 x 58.00
min
material
plastic, heat-resistant (UL94V-0)
typ
115
natural convection
MECHANICAL DRAWING
units: mm [inch]
ADJ: built-in trimpot
wire range: 24-12 AWG
tightening torque: Max 0.4 N·m
mounting rail: TS35
general tolerances: ±1.0 [±0.039]
TERMINAL
CONNECTIONS
TERMINAL
Function
1
AC (N)
2
AC (L)
3
-Vo
4
+Vo
units
mm
weight
cooling
max
cui.com
g
Additional Resources:
Product Page
CUI Inc │ SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
DERATING CURVE
EFFICIENCY CURVES
cui.com
|
3D Model
date 05/26/2022 │ page 5 of 6
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PDRB-30 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 05/26/2022 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
11/25/2020
1.01
correction to 24 Vdc efficiency and no-load power consumption
06/23/2021
1.02
derating curves updated
02/22/2022
UKCA mark added
05/26/2022
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PDRB-30-15”相匹配的价格&库存,您可以联系我们找货
免费人工找货