Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
08/09/2022
page
1 of 8
SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
1 W isolated output
smaller package
single and dual unregulated outputs
1,500 Vdc isolation
short circuit protection
extended temperature range (-40~105°C)
antistatic protection up to 8kV
high efficiency at light load
efficiency up to 82%
EN 62368-1
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise2
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
PDS1-S3-S3-M
3.3
2.97~3.63
3.3
30
303
1
60
69
PDS1-S3-S5-M
3.3
2.97~3.63
5
20
200
1
60
74
PDS1-S3-D5-M
3.3
2.97~3.63
±5
±10
±100
1
60
76
PDS1-S3-D12-M
3.3
2.97~3.63
±12
±5
±42
1
60
77
PDS1-S3-D15-M
3.3
2.97~3.63
±15
±3
±33
1
60
78
1
PDS1-S5-S3-M
5
4.5~5.5
3.3
30
303
1
60
72
PDS1-S5-S5-M1
5
4.5~5.5
5
20
200
1
60
80
PDS1-S5-S9-M
5
4.5~5.5
9
12
111
1
60
80
PDS1-S5-S12-M1
5
4.5~5.5
12
9
84
1
60
80
1
PDS1-S5-S15-M
5
4.5~5.5
15
7
67
1
60
80
PDS1-S5-S24-M1
5
4.5~5.5
24
4
42
1
60
80
PDS1-S5-D5-M
5
4.5~5.5
±5
±10
±100
1
60
80
PDS1-S5-D9-M
5
4.5~5.5
±9
±6
±56
1
60
80
PDS1-S5-D12-M
5
4.5~5.5
±12
±5
±42
1
60
79
PDS1-S5-D15-M
5
4.5~5.5
±15
±3
±33
1
60
81
PDS1-S5-D24-M
5
4.5~5.5
±24
±2
±21
1
60
81
1
PDS1-S12-S3-M
12
10.8~13.2
3.3
30
303
1
60
72
PDS1-S12-S5-M1
12
10.8~13.2
5
20
200
1
60
71
PDS1-S12-S9-M
12
10.8~13.2
9
12
111
1
60
80
PDS1-S12-S12-M1
12
10.8~13.2
12
9
84
1
60
80
PDS1-S12-S15-M
12
10.8~13.2
15
7
67
1
60
80
PDS1-S12-D5-M
12
10.8~13.2
±5
±10
±100
1
60
80
PDS1-S12-D9-M
12
10.8~13.2
±9
±6
±56
1
60
80
PDS1-S12-D12-M
12
10.8~13.2
±12
±5
±42
1
60
73
PDS1-S12-D15-M
12
10.8~13.2
±15
±3
±33
1
60
81
PDS1-S12-D24-M
12
10.8~13.2
±24
±2
±21
1
60
81
PDS1-S15-S15-M
15
13.5~16.5
15
7
67
1
60
80
1
1
1
1
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
MODEL
(CONTINUED)
input
voltage
date 08/09/2022 │ page 2 of 8
output
voltage
output
current
output
power
ripple
and noise2
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
PDS1-S24-S5-M1
24
21.6~26.4
5
20
200
1
60
73
PDS1-S24-S9-M1
24
21.6~26.4
9
12
111
1
60
80
PDS1-S24-S12-M
24
21.6~26.4
12
9
84
1
60
80
PDS1-S24-S15-M1
24
21.6~26.4
15
7
67
1
60
72
PDS1-S24-S24-M
24
21.6~26.4
24
4
42
1
60
80
PDS1-S24-D5-M
24
21.6~26.4
±5
±10
±100
1
60
70
PDS1-S24-D9-M
24
21.6~26.4
±9
±6
±56
1
60
80
PDS1-S24-D12-M
24
21.6~26.4
±12
±5
±42
1
60
72
PDS1-S24-D15-M
24
21.6~26.4
±15
±3
±33
1
60
71
PDS1-S24-D24-M
24
21.6~26.4
±24
±2
±21
1
60
80
1
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PDS1 - SXX - XXX - M - X
Base Number
Input Voltage
Output
S = single
D = dual
Output Voltage
Packaging Style
SMT
Package Options
"blank" = standard
TR = Tape & Reel
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
2.97
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.63
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
-0.7
5
9
18
21
30
Vdc
Vdc
Vdc
Vdc
Vdc
filter
capacitance filter
max
units
±1.5
±1.2
%
%
OUTPUT
parameter
conditions/description
min
line regulation
for Vin change of 1%
3.3 Vdc output models
all other models
load regulation
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
voltage accuracy
see tolerance envelope curve
switching frequency
100% load, nominal input voltage
temperature coefficient
100% load
typ
18
12
8
7
6
5
%
%
%
%
%
%
100
kHz
±0.03
cui.com
%/°C
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/09/2022 │ page 3 of 8
PROTECTIONS
parameter
conditions/description
short circuit protection1
3 & 24 Vdc input models
PDS1-S5-S12-M, PDS1-S5-D24-M
all other models: automatic recovery
Note:
min
typ
max
units
1
1
s
s
max
units
1. The supply voltage must be discontinued at the end of the short circuit duration
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
isolation capacitance
input to output at 100 kHz/0.1 V
safety approvals2
certified to 62368-1: EN
certified to 60950-1: UL
conducted emissions
CISPR32/EN55032, class B (external circuit required, see Figure 1)
radiated emissions
CISPR32/EN55032, class B (external circuit required, see Figure 1)
ESD
IEC/EN 61000-4-2, class B, contact ±8kV (single output models)
IEC/EN 61000-4-2, class B, contact ±6kV (dual output models)
MTBF
as per MIL-HDBK-217F @ 25 °C
RoHS
Note:
min
typ
20
pF
3,500,000
hours
2011/65/EU
2. See specific models noted on pages 1 & 2
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta=25°C
typ
max
units
-40
105
°C
-55
125
°C
95
%
25
°C
SOLDERABILITY
parameter
conditions/description
max
units
hand soldering
1.5 mm from case for 10 seconds
min
300
°C
reflow soldering
see reflow soldering profile
245
°C
25 0
24 5
Peak .Temp 245˚C( Max.)
21 7
Tem peratur e (˚C )
20 0
60 Sec Max
( >217˚
C)
15 0
10 0
50
0
typ
Tim e (se c.)
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/09/2022 │ page 4 of 8
MECHANICAL
parameter
conditions/description
dimensions
single output models: 12.7 x 8.30 x 7.25
dual output models: 15.24 x 8.30 x 7.25
min
case material
epoxy resin (UL94-V0)
weight
single output models
dual output models
SINGLE OUTPUT MODELS
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
Function
1
GND
2
Vin
4
0V
5
+Vo
8
NC
cui.com
max
units
mm
mm
1.6
2.0
MECHANICAL DRAWING
PIN
typ
g
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
DUAL OUTPUT MODELS
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
Function
1
GND
2
Vin
4
0V
5
-Vo
7
+Vo
10
NC
|
PCB Footprint
date 08/09/2022 │ page 5 of 8
MECHANICAL DRAWING (CONTINUED)
PIN
3D Model
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/09/2022 │ page 6 of 8
DERATING CURVES
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Recommended external circuit components
Single Outputs
Dual Outputs
Vout
(dc)
Cin
LDM
Cout
CY
3.3
4.7μF/50V
6.8μH
10μF
-
5
4.7μF/50V
6.8μH
10μF
-
9
4.7μF/50V
6.8μH
4.7μF
-
12
4.7μF/50V
6.8μH
2.2μF
-
15
4.7μF/50V
6.8μH
1μF
-
24
4.7μF/50V
6.8μH
0.47μF
-
±5
4.7μF/50V
6.8μH
4.7μF
-
±9
4.7μF/50V
6.8μH
2.2μF
-
±12
4.7μF/50V
6.8μH
1μF
-
±15
4.7μF/50V
6.8μH
1μF
1nF/2kV
±24
4.7μF/50V
6.8μH
0.47μF
1nF/2kV
Note:
cui.com
1. See Cout values in Tables 1 and 2.
2. 24 Vdc output models require CY also.
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PDS1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/09/2022 │ page 7 of 8
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR (see Figure 2 & Table 1). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 2). It’s not recommended to connect any external capacitors in applications with less than 0.5 watt output.
Figure 2
Single Outputs
Dual Outputs
Table 2
Single Vout
(Vdc)
Max. Capacitive Load
(μF)
Dual Vout
(Vdc)
Max. Capacitive Load1
(μF)
3.3
220
-
-
5
220
±5
100
9
220
±9
100
12
220
±12
100
15
220
±15
100
24
220
±24
100
Note:
4.
1. For each output.
Output Voltage Regulation and Over-voltage Protection Circuit
The device for output voltage regulation, over-voltage and over-current protection is a linear regulator and a capacitor filtering ne
work with overheat protection which can be connected to the input or output end in series (see Figure 3). The recommended
capacitance of its filter capacitor (see Table 1 & 2), and the linear regulator is based on the actual voltage and current required.
Figure 3
Single Outputs
Note:
1.
2.
3.
4.
Dual Outputs
Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
Max. capacitive load tested at input voltage range and full load.
It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
All specifications measured at: Ta=25°C, humidity
很抱歉,暂时无法提供与“PDS1-S5-S24-M”相匹配的价格&库存,您可以联系我们找货
免费人工找货