0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PDS2-S12-S15-M

PDS2-S12-S15-M

  • 厂商:

    CUI

  • 封装:

    SMD5 模块

  • 描述:

    隔离模块 直流转换器 1 输出 15V 133mA 10.8V - 13.2V 输入

  • 数据手册
  • 价格&库存
PDS2-S12-S15-M 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 09/26/2023 page 1 of 7 SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • 2 W isolated output smaller package single unregulated output 1,500 Vdc isolation short circuit protection extended temperature range (-40~105°C) high efficiency at light load efficiency up to 84% MODEL input voltage output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PDS2-S5-S3-M* 5 4.5~5.5 3.3 40 400 1.32 100 78 PDS2-S5-S5-M 5 4.5~5.5 5 40 400 2 100 79 PDS2-S5-S9-M* 5 4.5~5.5 9 22 222 2 100 82 PDS2-S5-S12-M 5 4.5~5.5 12 17 167 2 100 82 PDS2-S5-S15-M* 5 4.5~5.5 15 13 133 2 100 83 PDS2-S12-S5-M 12 10.8~13.2 5 40 400 2 100 79 PDS2-S12-S9-M* 12 10.8~13.2 9 22 222 2 100 82 PDS2-S12-S12-M 12 10.8~13.2 12 17 167 2 100 82 PDS2-S12-S15-M 12 10.8~13.2 15 13 133 2 100 83 PDS2-S12-S24-M* 12 10.8~13.2 24 8 83 2 100 84 PDS2-S15-S15-M 15 13.5~16.5 15 13 133 2 100 83 PDS2-S24-S5-M 24 21.6~26.4 5 40 400 2 100 79 PDS2-S24-S9-M* 24 21.6~26.4 9 22 222 2 100 82 PDS2-S24-S12-M* 24 21.6~26.4 12 17 167 2 100 82 PDS2-S24-S15-M 24 21.6~26.4 15 13 133 2 100 83 PDS2-S24-S24-M* 24 21.6~26.4 24 8 83 2 100 84 Notes: 1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. 2. * Discontinued model cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER date 09/26/2023 │ page 2 of 7 PART NUMBER KEY PDS2 - SXX - S XX - M - X Base Number Input Voltage Output S = single Output Voltage Packaging Style SMT Packaging Options "blank" = standard TR = Tape & Reel INPUT parameter conditions/description min typ max units operating input voltage 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models 4.5 10.8 13.5 21.6 5 12 15 24 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models -0.7 -0.7 -0.7 -0.7 9 18 21 30 Vdc Vdc Vdc Vdc filter capacitance filter max units ±1.5 ±1.2 % % OUTPUT parameter conditions/description line regulation for Vin change of 1% 3.3 Vdc output models all other models min load regulation measured from 10% load to full load 3.3 Vdc output models 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage temperature coefficient 100% load typ 18 12 9 8 7 6 % % % % % % 100 kHz ±0.03 %/°C max units 1 s max units PROTECTIONS parameter conditions/description min typ short circuit protection1 Notes: 1. The supply voltage must be discontinued at the end of the short circuit duration SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute at 1 mA max. 1,500 min Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ safety approvals designed to meet 62368: EN/BS EN conducted emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) radiated emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) ESD IEC/EN61000-4-2, class B, contact ± 8kV MTBF as per MIL-HDBK-217F at 25°C RoHS 2011/65/EU 3,500,000 cui.com typ hours Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER date 09/26/2023 │ page 3 of 7 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 105 °C -55 125 °C 95 % storage temperature storage humidity non-condensing temperature rise at full load, Ta = 25°C typ 25 °C SOLDERABILITY parameter conditions/description hand soldering reflow soldering min max units 1.5 mm from case for 10 seconds 300 °C see reflow soldering profile 245 °C cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER date 09/26/2023 │ page 4 of 7 MECHANICAL parameter conditions/description dimensions 12.70 x 11.20 x 7.25 (0.500 x 0.441 x 0.285 inch) min case material epoxy resin (UL94-V0) weight typ max mm 1.6 g MECHANICAL DRAWING units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] PIN CONNECTIONS PIN FUNCTION 1 GND 2 Vin 4 0V 5 +Vo 8 NC NC: No Connection Top View Side View Front View Top View PCB Layout cui.com units Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER date 09/26/2023 │ page 5 of 7 DERATING CURVES EMC RECOMMENDED CIRCUIT Figure 1 Table 1 Recommended external circuit components Vin (Vdc) C1 C2 CY1 LDM 5 4.7μF/50V 4.7μF/50V -- 6.8μH 12 4.7μF/50V 4.7μF/50V -- 6.8μH 15 4.7μF/50V 4.7μF/50V -- 6.8μH 24 4.7μF/50V 4.7μF/50V 1nF/2kV 6.8μH Note: cui.com 1. CY of 1nF/2kV required for PDS2-S12-S24-M 2. See Table 2 for Cout values Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER date 09/26/2023 │ page 6 of 7 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 3). Figure 2 Table 2 Note: Table 3 Vin (Vdc) Cin (µF) Vo (Vdc) Cout (µF) Vout (Vdc) Max. Capacitive Load (μF) 5 4.7 3.3 10 3.3 220 12 2.2 5 10 5 220 15 2.2 9 4.7 9 220 24 1 12 2.2 12 220 -- -- 15 1 15 220 -- -- 24 0.47 24 220 1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. 2. Max. capacitive load tested at input voltage range and full load. 3. All specifications measured at: Ta=25°C, humidity
PDS2-S12-S15-M 价格&库存

很抱歉,暂时无法提供与“PDS2-S12-S15-M”相匹配的价格&库存,您可以联系我们找货

免费人工找货