Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
11/10/2022
page
1 of 6
SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
2 W isolated output
single unregulated output
3,000 Vdc isolation
continuous short circuit protection
extended temperature range (-40~105°C)
efficiency up to 85%
designed to meet EN/BS EN 62368
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency2
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PESE2-S12-S5-M
12
10.8~13.2
5
40
400
2
150
83
PESE2-S12-S9-M
12
10.8~13.2
9
22
222
2
150
83
PESE2-S12-S12-M
12
10.8~13.2
12
17
167
2
150
84
PESE2-S12-S15-M
12
10.8~13.2
15
13
133
2
150
84
PESE2-S12-S24-M
12
10.8~13.2
24
8
83
2
150
85
PESE2-S15-S5-M
15
13.5~16.5
5
40
400
2
150
83
PESE2-S15-S15-M
15
13.5~16.5
15
13
133
2
150
84
PESE2-S24-S5-M
24
21.6~26.4
5
40
400
2
150
83
PESE2-S24-S9-M
24
21.6~26.4
9
22
222
2
150
83
PESE2-S24-S12-M
24
21.6~26.4
12
17
167
2
150
84
PESE2-S24-S15-M
24
21.6~26.4
15
13
133
2
150
84
PESE2-S24-S24-M
24
21.6~26.4
24
8
83
2
150
85
Notes:
1. Measured at nominal input, 20 MHz bandwidth oscilloscope with 10 µF tantalum and 1 µF ceramic capacitor on output (see Application circuit).
2. Measured at nominal input voltage, full load.
3. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
PESE2- S XX - S XX - M- XX
Base Number
Input Voltage
Output:
Output Voltage
S = single
cui.com
Mounting Style:
SMT
Packaging:
“blank” = Tube
TR = Tape and Reel
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
date 11/10/2022 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
12 Vdc input models
15 Vdc input models
24 Vdc input models
10.8
13.5
21.6
12
15
24
13.2
16.5
26.4
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
18
21
30
Vdc
Vdc
Vdc
current
12 Vdc input models
15 Vdc input models
24 Vdc input models
196
161
98
mA
mA
mA
filter
filter capacitor
OUTPUT
parameter
conditions/description
maximum capacitive load
5 Vdc output models
9 Vdc output models
12, 15 Vdc output models
24 Vdc output models
max
units
2,400
1,000
560
220
μF
μF
μF
μF
voltage accuracy
see output regulation curves
line regulation
for Vin change of ±1%
±1.2
%
load regulation
from 10% to full load
5 Vdc output models
all other models
±15
±10
%
%
switching frequency
100% load, nominal input voltage
temperature coefficient
at full load
4
Note:
min
typ
260
kHz
±0.02
%/°C
4. Tested at input voltage range and full load.
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, auto recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA
3,000
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
isolation capacitance
input to output, 100 kHz / 0.1 V
safety approvals
designed to meet 62368: EN/BS EN
conducted emissions
CISPR 32/EN 55032 Class B
radiated emissions
CISPR 32/EN 55032 Class B
ESD
IEC/EN 61000-4-2 Air ±8kV, Contact ±6kV
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
yes
20
pF
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
105
°C
-55
125
°C
5
95
%
storage temperature
storage humidity
non-condensing
case temperature rise
at 25°C
typ
25
cui.com
°C
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 11/10/2022 │ page 3 of 6
DERATING CURVES
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
date 11/10/2022 │ page 4 of 6
MECHANICAL
parameter
conditions/description
dimensions
13.20 x 11.40 x 7.25 [0.520 x 0.448 x 0.285 inch]
min
case material
black flame-retardant and heat-resistant plastic (UL94V-0)
weight
typ
units: mm [inch]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 [±0.004]
PIN CONNECTIONS
PIN
Function
1
GND
2
Vin
4
0V
5
+Vo
8
NC
NC = No connect
cui.com
units
mm
1.4
MECHANICAL DRAWING
max
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
date 11/10/2022 │ page 5 of 6
APPLICATION CIRCUIT
If you want to further reduce the input and output ripple, a filter capacitor may be connected to the input and output
terminals (Figure 1) provided that the capacitance is less than the maximum capacitive load of the model, otherwise startup problems may be caused if the capacitance is too large.
Figure 1
Table 1
EMC RECOMMENDED CIRCUIT
Figure 2
Table 3
Recommended External Circuit Components
C1, C2
4.7 µF / 50 V
C3
refer to the Cout in Table 1
CY
270 pF / 3 kV
LDM
6.8 μH
cui.com
Vin
(Vdc)
Cin
(μF / V)
Vo
(Vdc)
Cout
(μF / V)
12
2.2 / 25
5
10 / 10
15
1 / 25
9
2.2 / 25
24
1 / 50
12
2.2 / 25
---
---
15
1 / 25
---
---
24
0.47 / 50
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PESE2-M │ DESCRIPTION: DC-DC CONVERTER
date 11/10/2022 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
07/23/2021
1.01
model table updated
01/05/2022
1.02
CE certification added to PESE2-S15-S15-M
08/11/2022
1.03
CE certification removed
11/10/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PESE2-S24-S24-M”相匹配的价格&库存,您可以联系我们找货
免费人工找货