0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PQP3-D12-S15-D

PQP3-D12-S15-D

  • 厂商:

    CUI

  • 封装:

    DIP5 模块

  • 描述:

    隔离模块 直流转换器 1 输出 15V 200mA 9V - 18V 输入

  • 数据手册
  • 价格&库存
PQP3-D12-S15-D 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 11/22/2022 page 1 of 7 SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • wide 2:1 input range single and Dual output options 1500 Vdc isolation industry standard pin-out ultra compact DIP package short circuit protection (continuous) wide operating temp: -40°C to +85°C supports negative output (dual output model) designed to meet EN/BS EN 62368 MODEL input voltage output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PQP3-D12-S3-D 12 9~18 3.3 38 758 2.5 100 75 PQP3-D12-S5-D 12 9~18 5 30 600 3 100 79 PQP3-D12-S12-D 12 9~18 12 13 250 3 100 82 PQP3-D12-S15-D 12 9~18 15 10 200 3 100 83 PQP3-D12-S24-D 12 9~18 24 6 125 3 100 81 PQP3-D24-S3-D 24 18~36 3.3 38 758 2.5 100 74 PQP3-D24-S5-D 24 18~36 5 30 600 3 100 81 PQP3-D24-S12-D 24 18~36 12 13 250 3 100 83 PQP3-D24-S15-D 24 18~36 15 10 200 3 100 83 PQP3-D24-S24-D 24 18~36 24 6 125 3 100 83 PQP3-D12-D5-D 12 9~18 ±5 ±15 ±300 3 100 78 PQP3-D12-D9-D 12 9~18 ±9 ±9 ±167 3 100 78 PQP3-D12-D12-D 12 9~18 ±12 ±7 ±125 3 100 79 PQP3-D12-D15-D 12 9~18 ±15 ±5 ±100 3 100 79 PQP3-D24-D5-D 24 18~36 ±5 ±15 ±300 3 100 78 PQP3-D24-D9-D 24 18~36 ±9 ±9 ±167 3 100 80 PQP3-D24-D12-D 24 18~36 ±12 ±7 ±125 3 100 82 PQP3-D24-D15-D 24 18~36 ±15 ±5 ±100 3 100 81 Notes: 1. Ripple & noise testing condition at nominal input voltage and 5%-100% load, the “tip and barrel” method is used for ripple and noise test, please refer to DC-DC Converter Application Notes for specific information. PART NUMBER KEY PQP3 - DXX - XXX - D Base Number Input Voltage Output S = single D = dual cui.com Output Voltage Packaging Style DIP Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 2 of 7 INPUT parameter conditions/description input voltage 12 Vdc input models 24 Vdc input models start-up voltage 12 Vdc input models 24 Vdc input models surge voltage for maximum of 1 second 12 Vdc input models 24 Vdc input models filter capacitance filter current full load/no load 12 Vdc input models 24 Vdc input models min typ max units 9 18 12 24 18 36 Vdc Vdc 9 18 Vdc Vdc 25 50 Vdc Vdc 314/30 154/20 338/50 165/40 mA mA typ max units ±0.2 ±0.5 ±0.5 ±1 % % ±0.5 ±1 ±3 % % ±1 ±3 ±3 ±5 % % -0.7 -0.7 OUTPUT parameter conditions/description min line regulation min to max Vin positive outputs negative outputs load regulation 5% ~ 100% load positive outputs negative outputs set-point accuracy 5% ~ 100% load positive outputs negative outputs switching frequency full load, nominal input 300 transient response 25% load step change ±2.5 temperature coefficient full load kHz ±5 % ±0.03 %/°C max units PROTECTIONS parameter conditions/description short circuit protection continuous, self-recovery min cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 3 of 7 SAFETY AND COMPLIANCE parameter conditions/description min isolation voltage input-output electric strength test for 1 minute 1500 typ isolation resistance input-output insulation at 500 Vdc 1000 isolation capacitance input-output capacitance at 100 KHz / 0.1 V safety approvals designed to meet 62368: EN/BS EN EMC CISPR32/EN55032 Class B (see recommended circuit) ESD IEC/EN61000-4-2, Contact ±6K, perf. Criteria B radiated immunity IEC/EN61000-4-3, 10 v/m, perf. Criteria A EFT/burst IEC/EN61000-4-4, ±2KV, perf. Criteria B (see recommended circuit) surge IEC/EN61000-4-5, line to line ±2KV, perf. Criteria B (see recommended circuit) conducted immunity IEC/EN61000-4-6 3 Vrms, perf. Criteria A RoHS yes MTBF MIL-HDBK-217F @ 25°C max units Vdc MΩ 100 pF 1000 kHours ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -40 85 °C storage temperature -55 125 °C 5 95 % humidity non-condensing SOLDERABILITY parameter conditions/description max units hand soldering 1.5 mm from case for 10 seconds min 300 °C reflow soldering 60 s max over 217°C 245 °C DERATING CURVE cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 4 of 7 MECHANICAL parameter conditions/description dimensions 14 x 14 x 9 min case material Black plastic; flame-retardant and heat-resistant typ 2.2 MECHANICAL DRAWING units: mm [inches] tolerance: ± 0.50 [±0.020] PIN CONNECTIONS Single Dual 1 GND GND 4 Vin Vin 5 +Vo +Vo 6 NC 0V 7 0V -Vo units mm weight PIN max cui.com g Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 5 of 7 RECOMMENDED CIRCUITS Figure 1 Table 1 Single output Parameter Description / Single Output Vin (Vdc) 12 24 Cin 47uF/25V 47uF/50V Vo (Vdc) 3.3, 5 12, 15, 24 Co 100uF/6.3V 27uF/35V Dual output Parameter Description / Dual Output Vin (Vdc) 12 24 Cin 47uF/50V 47uF/50V Vo (Vdc) 5, 9 12, 15 Co 47uF/16V 10uF/35V EMC COMPLIANCE CIRCUITS Figure 2 Single output Table 2 Parameter Description Part No. Vo (Vdc) FUSE C0 C1 Vin: 12 Vdc 3.3 5 12 Vin: 24 Vdc 15 24 3.3 5 12 15 24 slow blow, choose according to actual input current 1000µF/25V 10µF/50V 680µF/50V 4.7µF/50V 10µF/50V LDM1 15µH C2 4.7µF/50V C3 330µF/50V CY1 1nF/2KV C4 Refer to the Cout Fig.1 cui.com 4.7µF/50V Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 6 of 7 EMC COMPLIANCE CIRCUITS (CONTINUED) Figure 3 Dual output Table 3 Parameter Description Part No. Vo (Vdc) FUSE C0 Vin: 12 Vdc ±5 ±9 ±12 Vin: 24 Vdc ±15 ±5 ±9 ±12 slow blow, choose according to actual input current 1000µF/25V C1 680µF/50V 4.7µF/50V LDM1 10µH C2 10µF/50V C3 330µF/50V CY1 1nF/2000V 470pF/2000V 1nF/2000V CY2 1nF/2000V 470pF/2000V 1nF/2000V CY3 1nF/2000V 470pF/2000V / C4, C5 Refer to the Cout Fig.1 cui.com ±15 Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER date 11/22/2022 │ page 7 of 7 REVISION HISTORY rev. description date 1.0 initial release 03/28/2020 1.01 units updated in the mechanical drawing section 10/19/2020 1.02 derating curve and circuit figures updated 07/14/2021 1.03 dual diagrams added 04/06/2022 CE certification removed 11/22/2022 1.04 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PQP3-D12-S15-D 价格&库存

很抱歉,暂时无法提供与“PQP3-D12-S15-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货