Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
11/22/2022
page
1 of 7
SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
wide 2:1 input range
single and Dual output options
1500 Vdc isolation
industry standard pin-out
ultra compact DIP package
short circuit protection (continuous)
wide operating temp: -40°C to +85°C
supports negative output (dual output model)
designed to meet EN/BS EN 62368
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PQP3-D12-S3-D
12
9~18
3.3
38
758
2.5
100
75
PQP3-D12-S5-D
12
9~18
5
30
600
3
100
79
PQP3-D12-S12-D
12
9~18
12
13
250
3
100
82
PQP3-D12-S15-D
12
9~18
15
10
200
3
100
83
PQP3-D12-S24-D
12
9~18
24
6
125
3
100
81
PQP3-D24-S3-D
24
18~36
3.3
38
758
2.5
100
74
PQP3-D24-S5-D
24
18~36
5
30
600
3
100
81
PQP3-D24-S12-D
24
18~36
12
13
250
3
100
83
PQP3-D24-S15-D
24
18~36
15
10
200
3
100
83
PQP3-D24-S24-D
24
18~36
24
6
125
3
100
83
PQP3-D12-D5-D
12
9~18
±5
±15
±300
3
100
78
PQP3-D12-D9-D
12
9~18
±9
±9
±167
3
100
78
PQP3-D12-D12-D
12
9~18
±12
±7
±125
3
100
79
PQP3-D12-D15-D
12
9~18
±15
±5
±100
3
100
79
PQP3-D24-D5-D
24
18~36
±5
±15
±300
3
100
78
PQP3-D24-D9-D
24
18~36
±9
±9
±167
3
100
80
PQP3-D24-D12-D
24
18~36
±12
±7
±125
3
100
82
PQP3-D24-D15-D
24
18~36
±15
±5
±100
3
100
81
Notes:
1. Ripple & noise testing condition at nominal input voltage and 5%-100% load, the “tip and barrel” method is used for ripple and noise test, please
refer to DC-DC Converter Application Notes for specific information.
PART NUMBER KEY
PQP3 - DXX - XXX - D
Base Number
Input Voltage
Output
S = single
D = dual
cui.com
Output Voltage
Packaging Style
DIP
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 2 of 7
INPUT
parameter
conditions/description
input voltage
12 Vdc input models
24 Vdc input models
start-up voltage
12 Vdc input models
24 Vdc input models
surge voltage
for maximum of 1 second
12 Vdc input models
24 Vdc input models
filter
capacitance filter
current
full load/no load
12 Vdc input models
24 Vdc input models
min
typ
max
units
9
18
12
24
18
36
Vdc
Vdc
9
18
Vdc
Vdc
25
50
Vdc
Vdc
314/30
154/20
338/50
165/40
mA
mA
typ
max
units
±0.2
±0.5
±0.5
±1
%
%
±0.5
±1
±3
%
%
±1
±3
±3
±5
%
%
-0.7
-0.7
OUTPUT
parameter
conditions/description
min
line regulation
min to max Vin
positive outputs
negative outputs
load regulation
5% ~ 100% load
positive outputs
negative outputs
set-point accuracy
5% ~ 100% load
positive outputs
negative outputs
switching frequency
full load, nominal input
300
transient response
25% load step change
±2.5
temperature coefficient
full load
kHz
±5
%
±0.03
%/°C
max
units
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, self-recovery
min
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 3 of 7
SAFETY AND COMPLIANCE
parameter
conditions/description
min
isolation voltage
input-output electric strength test for 1 minute
1500
typ
isolation resistance
input-output insulation at 500 Vdc
1000
isolation capacitance
input-output capacitance at 100 KHz / 0.1 V
safety approvals
designed to meet 62368: EN/BS EN
EMC
CISPR32/EN55032 Class B (see recommended circuit)
ESD
IEC/EN61000-4-2, Contact ±6K, perf. Criteria B
radiated immunity
IEC/EN61000-4-3, 10 v/m, perf. Criteria A
EFT/burst
IEC/EN61000-4-4, ±2KV, perf. Criteria B (see recommended circuit)
surge
IEC/EN61000-4-5, line to line ±2KV, perf. Criteria B (see recommended circuit)
conducted immunity
IEC/EN61000-4-6 3 Vrms, perf. Criteria A
RoHS
yes
MTBF
MIL-HDBK-217F @ 25°C
max
units
Vdc
MΩ
100
pF
1000
kHours
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
operating temperature
-40
85
°C
storage temperature
-55
125
°C
5
95
%
humidity
non-condensing
SOLDERABILITY
parameter
conditions/description
max
units
hand soldering
1.5 mm from case for 10 seconds
min
300
°C
reflow soldering
60 s max over 217°C
245
°C
DERATING CURVE
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
14 x 14 x 9
min
case material
Black plastic; flame-retardant and heat-resistant
typ
2.2
MECHANICAL DRAWING
units: mm [inches]
tolerance: ± 0.50 [±0.020]
PIN CONNECTIONS
Single
Dual
1
GND
GND
4
Vin
Vin
5
+Vo
+Vo
6
NC
0V
7
0V
-Vo
units
mm
weight
PIN
max
cui.com
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 5 of 7
RECOMMENDED CIRCUITS
Figure 1
Table 1
Single output
Parameter Description / Single Output
Vin (Vdc)
12
24
Cin
47uF/25V
47uF/50V
Vo (Vdc)
3.3, 5
12, 15, 24
Co
100uF/6.3V
27uF/35V
Dual output
Parameter Description / Dual Output
Vin (Vdc)
12
24
Cin
47uF/50V
47uF/50V
Vo (Vdc)
5, 9
12, 15
Co
47uF/16V
10uF/35V
EMC COMPLIANCE CIRCUITS
Figure 2
Single output
Table 2
Parameter Description
Part No.
Vo (Vdc)
FUSE
C0
C1
Vin: 12 Vdc
3.3
5
12
Vin: 24 Vdc
15
24
3.3
5
12
15
24
slow blow, choose according to actual input current
1000µF/25V
10µF/50V
680µF/50V
4.7µF/50V
10µF/50V
LDM1
15µH
C2
4.7µF/50V
C3
330µF/50V
CY1
1nF/2KV
C4
Refer to the Cout Fig.1
cui.com
4.7µF/50V
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 6 of 7
EMC COMPLIANCE CIRCUITS (CONTINUED)
Figure 3
Dual output
Table 3
Parameter Description
Part No.
Vo (Vdc)
FUSE
C0
Vin: 12 Vdc
±5
±9
±12
Vin: 24 Vdc
±15
±5
±9
±12
slow blow, choose according to actual input current
1000µF/25V
C1
680µF/50V
4.7µF/50V
LDM1
10µH
C2
10µF/50V
C3
330µF/50V
CY1
1nF/2000V
470pF/2000V
1nF/2000V
CY2
1nF/2000V
470pF/2000V
1nF/2000V
CY3
1nF/2000V
470pF/2000V
/
C4, C5
Refer to the Cout Fig.1
cui.com
±15
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQP3-D │ DESCRIPTION: DC-DC CONVERTER
date 11/22/2022 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
03/28/2020
1.01
units updated in the mechanical drawing section
10/19/2020
1.02
derating curve and circuit figures updated
07/14/2021
1.03
dual diagrams added
04/06/2022
CE certification removed
11/22/2022
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PQP3-D24-S5-D”相匹配的价格&库存,您可以联系我们找货
免费人工找货