0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PQQ10W-Q24-S9-S

PQQ10W-Q24-S9-S

  • 厂商:

    CUI

  • 封装:

    SIP-7

  • 描述:

    隔离模块 直流转换器 1 输出 9V 1.111A 9V - 36V 输入

  • 数据手册
  • 价格&库存
PQQ10W-Q24-S9-S 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 03/09/2023 page 1 of 8 SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • 10W isolated output ultra wide 4:1 input range single regulated output high efficiency up to 88% short circuit and over-current protection 1500 Vdc isolation operating temperature -40°C ~ 85°C designed to meet EN/BS EN 62368 control pin MODEL input voltage output voltage output current output power ripple & noise1 efficiency² typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PQQ10W-Q24-S3-S 24 9~36 3.3 0 2,400 8 150 84 PQQ10W-Q24-S5-S 24 9~36 5.0 0 2,000 10 150 87 PQQ10W-Q24-S9-S 24 9~36 9.0 0 1,111 10 150 88 PQQ10W-Q24-S12-S 24 9~36 12.0 0 833 10 150 88 PQQ10W-Q24-S15-S 24 9~36 15.0 0 667 10 150 88 PQQ10W-Q24-S24-S 24 9~36 24.0 0 417 10 150 87 Notes: 1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method. See figure 3. 2. At nominal input voltage. PART NUMBER KEY PQQ10W - QXX - S XX - S Base Number Input Voltage Output S = single cui.com Output Voltage Packaging style S = SIP Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER date 03/09/2023 │ page 2 of 8 INPUT parameter conditions/description operating input voltage min typ max units 9 24 40 Vdc start-up voltage surge voltage for maximum of 1 second -0.7 current full load / no load 3.3 Vdc output 5 Vdc output other outputs filter capacitance filter CTRL module on: CTRL pin open or pulled high (3.5-12 Vdc) module off: CTRL pin pulled low to GND (0-1.2 Vdc) 389/25 474/25 474/9 9 Vdc 50 Vdc 398/45 485/45 485/18 mA mA mA OUTPUT parameter conditions/description maximum capacitive load 3.3 & 5 Vdc output 9 Vdc output 12 Vdc output 15 Vdc output 24 Vdc output min typ voltage accuracy line regulation max units 2,200 680 470 330 220 μF μF μF μF μF ±2 % ±0.5 % ±1 % load regulation 5%~100% load switching frequency PWM mode 500 transient recovery time 25% load step change 300 500 μS transient response deviation nominal input voltage 3.3 & 5 Vdc output other outputs ±5 ±3 ±8 ±5 % % temperature coefficient at full load ±0.03 %/°C cui.com kHz Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER date 03/09/2023 │ page 3 of 8 PROTECTIONS parameter conditions/description min over current protection short circuit protection typ 110 max units 230 % max units continuous, auto recovery SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output, for 1 minute with 1 mA max 1,500 min typ Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ isolation capacitance input to output, 100 kHz / 0.1 V safety approvals designed to meet 62368: EN, BS EN EMI/EMC CISPR32/EN 55032 Class B (see recommended circuit) ESD IEC/EN61000-4-2 Contact ±6KV, perf. Criteria B radiated immunity IEC/EN61000-4-3 10V/m, perf. Criteria A EFT/burst IEC/EN61000-4-4 ±2KV (see recommended circuit), perf. Criteria B surge IEC/EN61000-4-5 line to line ±2KV (see recommended circuit), perf. Criteria B conducted immunity IEC/EN61000-4-6 3 Vr.m.s, perf. Criteria A MTBF as per MIL-HDBK-217F, 25°C RoHS yes 1,000 pF 1,000 K hours ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature storage humidity non-condensing vibration 10-150Hz, 0.75mm, 5G, 90min. along X, Y and Z cui.com typ max units -40 85 °C -55 125 °C 5 95 % Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER date 03/09/2023 │ page 4 of 8 MECHANICAL parameter conditions/description dimensions 22.00 × 9.50 × 12.00 [0.866 x 0.374 x 0.472 inch] min case material black plastic weight typ units: mm [inch] pin section tolerance: ±0.10[±0.004] general tolerance: ±0.50[±0.020] PIN Out PIN Function 1 GND 2 Vin 3 Ctrl 5 NC 6 +Vo 7 0V 8 NC NC: Pin to be isolated from circuitry. cui.com units mm 5.5 MECHANICAL DRAWING max g Additional Resources: Product Page | CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER 3D Model | PCB Footprint date 03/09/2023 │ page 5 of 8 DERATING CURVES EFFICIENCY CURVES cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER date 03/09/2023 │ page 6 of 8 APPLICATION CIRCUIT Figure 1 Table 1 Cin (μF) Co (μF) 47 22 EMC RECOMMENDED CIRCUIT Figure 2 Note: For EMC tests part 1 was used for imunity and part 2 for emissions test. Table 2 Model Vin:24V FUSE Choose according to actual input current C0, C4 330μF/50V C1, C2 10μF/50V C3 22μF/50V LCM1 1.4-1.7mH (TN150-RH12.7*12.7*7.9) CY1, CY2 1nF/2000Vac cui.com Additional Resources: Product Page | CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER 3D Model | PCB Footprint date 03/09/2023 │ page 7 of 8 RIPPLE AND NOISE Figure 3 cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQQ10W-S │ DESCRIPTION: DC-DC CONVERTER date 03/09/2023 │ page 8 of 8 REVISION HISTORY rev. description date 1.0 initial release 09/29/2020 1.01 efficiency values updated and ripple and noise updated for 3 Vdc & 5 Vdc outuput models 09/26/2022 1.02 product image updated 10/17/2022 1.03 CE certification updated 11/22/2022 1.04 efficiency values updated 03/09/2023 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PQQ10W-Q24-S9-S 价格&库存

很抱歉,暂时无法提供与“PQQ10W-Q24-S9-S”相匹配的价格&库存,您可以联系我们找货

免费人工找货