Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
02/07/2023
page
1 of 9
SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
6W isolated output
ultra wide 4:1 input range
single and dual regulated outputs
high efficiency up to 87%
short circuit and over-current protection
1,600 Vdc isolation
operating temperature -40°C ~ 105°C
control pin
designed to meet EN/BS EN 62368
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency²
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PQQ6W-Q24-S3-S
24
9~36
3.3
0
1,350
4
100
78
PQQ6W-Q24-S5-S
24
9~36
5.0
0
1,200
6
100
82
PQQ6W-Q24-S9-S
24
9~36
9.0
0
667
6
100
84
PQQ6W-Q24-S12-S
24
9~36
12.0
0
500
6
100
86
PQQ6W-Q24-S15-S
24
9~36
15.0
0
400
6
100
87
PQQ6W-Q24-S24-S
24
9~36
24.0
0
250
6
100
85
PQQ6W-Q24-D5-S
24
9~36
±5
0
±600
6
150
80
PQQ6W-Q24-D9-S
24
9~36
±9
0
±333
6
150
83
PQQ6W-Q24-D12-S
24
9~36
±12
0
±250
6
150
83
PQQ6W-Q24-D15-S
24
9~36
±15
0
±200
6
150
83
PQQ6W-Q24-D24-S
24
9~36
±24
0
±125
6
150
82
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method. See Figure 3.
2. At nominal input voltage.
3. Exceeding the maximum input voltage may cause permanent damage.
PART NUMBER KEY
PQQ6W - QXX - X XX - S
Base Number
Input Voltage
Output
S = single
D = dual
cui.com
Output Voltage
Packaging style
S = SIP
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
date 02/07/2023 │ page 2 of 9
INPUT
parameter
conditions/description
operating input voltage
min
typ
max
units
9
24
40
Vdc
start-up voltage
surge voltage
for maximum of 1 second
-0.7
current
full load / no load
3.3 Vdc output
5 Vdc output
9, 12, 15, 24 Vdc output
±5 Vdc output
±9, ±12, ±15 Vdc output
±24 Vdc output
filter
capacitance filter
CTRL
module on: CTRL pin open or pulled high (3.5-12 Vdc)
module off: CTRL pin pulled low to GND (0-1.2 Vdc)
283/5
305/5
305/10
313/12
301/12
305/12
9
Vdc
50
Vdc
245/12
313/12
313/16
320/16
309/16
313/16
mA
mA
mA
mA
mA
mA
OUTPUT
parameter
conditions/description
maximum capacitive load4
3.3 Vdc output
5 Vdc output
±5, 9 & 12 Vdc output
±9, 15 Vdc output
±12 Vdc output
±15, 24 Vdc output
±24 Vdc output
voltage accuracy
5%~100% load
line regulation
max
units
1,800
1,000
470
220
120
100
68
μF
μF
μF
μF
μF
μF
μF
Vout1
Vout2
±2
±3
%
%
at full load, from low to
high input voltage
Vout1
Vout2
±1
±1.5
%
%
load regulation
5%~100% load
Vout1
Vout2
±1.5
±2
%
%
switching frequency
PWM mode
500
transient recovery time
25% load step change, nominal input voltage
single output models
dual output models
300
450
500
500
μS
μS
transient response deviation
25% load step change, nominal input voltage
±9, ±12, ±15 & ±24 Vdc output
all other outputs
±3
±5
±5
±8
%
%
temperature coefficient
at full load
±0.03
%/°C
Notes:
min
4. The specified maximum capacitive load for positive and negative output is identical.
cui.com
typ
kHz
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
date 02/07/2023 │ page 3 of 9
PROTECTIONS
parameter
conditions/description
min
over current protection
short circuit protection
typ
110
max
units
230
%
max
units
continuous, auto recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output, for 1 minute with 1 mA max
single output models
dual output models
min
typ
1,600
1,500
isolation resistance
input to output at 500 Vdc
1,000
isolation capacitance
input to output, 100 kHz / 0.1 V
safety approvals
designed to meet 62368-1: EN/BS EN
EMI/EMC
CISPR32/EN 55032 Class B (see recommended circuit)
ESD
IEC/EN 61000-4-2 Contact ±4kV, perf. Criteria B
radiated immunity
IEC/EN61000-4-3 10V/m, perf. Criteria A
EFT/burst
IEC/EN61000-4-4 ±2KV (see recommended circuit), perf. Criteria B
surge
IEC/EN61000-4-5 line to line ±2KV (see recommended circuit), perf. Criteria B
conducted immunity
IEC/EN61000-4-6 3 Vr.m.s, perf. Criteria A
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
yes
Vdc
Vdc
MΩ
1,000
pF
1,000
K hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
single output models
dual output models
storage temperature
storage humidity
non-condensing
vibration
10-150Hz, 5G, 0.75mm. along X, Y and Z
cui.com
typ
max
units
-40
-40
105
85
°C
°C
-55
125
°C
5
95
%
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
date 02/07/2023 │ page 4 of 9
MECHANICAL
parameter
conditions/description
dimensions
22.00 × 9.50 × 12.00 [0.866 x 0.374 x 0.472 inch]
min
case material
black plastic
weight
typ
units: mm [inch]
pin section tolerance: ±0.10[±0.004]
general tolerance: ±0.50[±0.020]
PIN Out
PIN
Function
Single output
Function
Dual output
1
GND
GND
2
Vin
Vin
3
Ctrl
Ctrl
5
NC
NC
6
+Vout
+Vout
7
0V
0V
8
NC
-Vout
NC: Pin to be isolated from circuitry.
cui.com
units
mm
4.9
MECHANICAL DRAWING
max
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 02/07/2023 │ page 5 of 9
DERATING CURVE
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 02/07/2023 │ page 6 of 9
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
date 02/07/2023 │ page 7 of 9
APPLICATION CIRCUIT
All the DC-DC converters of this series are tested before delivery using the recommended circuit shown in Fig. 1.
Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor values Cin and
Cout and/or by selecting capacitors with a low ESR (equivalent series resistance). Also make sure that the capacitance is
not exceeding the max. capacitive load value of the product.
Figure 1
Single output
Table 1
Dual output
Cin (μF/V)
Cout (μF/V)
100μF / 50V
22μF / 50V
EMC RECOMMENDED CIRCUIT
Figure 2
Single output
Table 2
Model
FUSE
Dual output
Dual output
Choose according to actual
input current
C0, C4
330μF/50V
330μF/100V
C1, C2
10μF/50V
10μF/50V
C3
22μF/50V
10μF/50V
LCM1
cui.com
Single output
1.4-1.7mH
(TN150-RH12.7*12.7*7.9)
LDM1
---
10μH
CY1, CY2
1nF/400V
1nF/2kV
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 02/07/2023 │ page 8 of 9
RIPPLE AND NOISE
Figure 3
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PQQ6W-S │ DESCRIPTION: DC-DC CONVERTER
date 02/07/2023 │ page 9 of 9
REVISION HISTORY
rev.
description
date
1.0
initial release
09/22/2020
1.01
datasheet update
01/21/2021
1.02
product image updated, dual output models added
11/07/2022
1.03
CE safety mark removed
11/22/2022
1.04
efficiency curves updated
12/13/2022
1.05
features updated
02/07/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PQQ6W-Q24-S3-S”相匹配的价格&库存,您可以联系我们找货
免费人工找货