Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
01/16/2023
page
1 of 9
SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
10W isolated output
ultra-wide 18:1 input range (8.5~160 Vdc)
single/dual regulated outputs
4,200 Vdc isolation
over voltage, over current, short circuit, UVLO protection
certified to IEC/BS EN/UL 62368-1
meets EN 50155 with external circuit
reinforced insulation
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency²
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PRC10W-72-S5
72
8.5 ~ 160
5
0
2,000
10
100
84
PRC10W-72-S12
72
8.5 ~ 160
12
0
835
10
100
88
PRC10W-72-S15
72
8.5 ~ 160
15
0
668
10
100
88
PRC10W-72-D5
72
8.5 ~ 160
±5
0
±1,000
10
100
83
PRC10W-72-D12
72
8.5 ~ 160
±12
0
±416
10
100
87
PRC10W-72-D15
72
8.5 ~ 160
±15
0
±333
10
100
87
Notes:
1. Measured at 5Hz to 20MHz bandwidth, peak to peak.
2. At nominal input voltage 72Vdc.
PART NUMBER KEY
PRC10W - 72 -X XX
Base Number
Input Voltage
cui.com
Output
S = single
D = dual
Output Voltage
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
date 01/16/2023 │ page 2 of 9
INPUT
parameter
conditions/description
operating input voltage
surge voltage
input undervoltage lockout
min
typ
max
units
8.5
72
160
Vdc
for maximum of 100 ms
200
Vdc
turn-on voltage treshold
at 80% load
8.2
9
9.5
Vdc
turn-off voltage treshold
at 80% load
6.9
7.5
8.0
Vdc
lockout hysteresis voltage
at 80% load
1.5
Vdc
current
Vin = 12V, full load
Vin = 8.5V, 80% load
input filter
LC filter
inrush current (I2t)
as per ETS300 132-2
input reflected ripple current
P-P thru 12uH inductor, 5Hz to 20MHz
30
CTRL
module on: CTRL pin open or pulled high (3.5~160 Vdc)
module off: CTRL pin pulled low to GND (0~1.2 Vdc)
CTRL pin current when pulled low
0.4
1
mA
typ
max
units
2,000
835
668
1,000
416
333
μF
μF
μF
μF
μF
μF
±1
%
1.3
A
0.1
A2s
mA
OUTPUT
parameter
conditions/description
min
maximum capacitive load
5 Vdc output
12 Vdc output
15 Vdc output
±5 Vdc output
±12 Vdc output
±15 Vdc output
voltage accuracy
Vin = 72V, full load, 25°C
output voltage balance
Vin = 72V, full load, 25°C, dual models only
±1
%
line regulation
input voltage from low to high, full load
±0.2
%
load regulation
0%~100% load
single output models
dual output models
±0.5
±1
%
%
cross regulation
load cross variation 25%/100%, dual output models
±5
%
switching frequency
280
kHz
transient recovery time
75% to 100% load step change, 0.1 A/us,
within 1% nominal input voltage
230
250
μs
transient response deviation
75% to 100% load step change, 0.1 A/us
±5
%
temperature coefficient
40°C to 100°C
±0.02
%/°C
cui.com
255
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
date 01/16/2023 │ page 3 of 9
PROTECTIONS
parameter
conditions/description
over voltage protection
zener clamp, single output only
5 Vdc output
12 Vdc output
15 Vdc output
min
over current protection
auto recovery, hiccup
short circuit protection
continuous, auto recovery
typ
max
units
6.2
15
18
110
150
min
typ
Vdc
Vdc
Vdc
180
%
max
units
3,000
4,200
Vac
Vdc
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output, for 1 minute
isolation resistance
input to output
isolation capacitance
input to output, 100kHz / 0.25V
safety approvals
certified to 62368: IEC, BS EN, UL
designed to meet 50155: EN
designed to meet 45545-2: EN
conducted emissions
EN55032 and EN50155 Compliant (with external filter)
radiated emissions
EN55032 and EN50155 Compliant (with external filter)
ESD
EN 61000-4-2 Level 3: Air ±8kV, Contact± 6kV, perf. Criteria A
radiated immunity
EN 61000-4-3 Level 3: 80~1000MHz, 20 V/m, perf. Criteria A
EFT/burst
EN61000-4-4 Level 3: On power input port, ±2kV, external input capacitor required, perf. Criteria A
surge
EN 61000-4-5 Level 4: Line to earth, ±4kV, line to line, ±2kV, perf. Criteria A
conducted immunity
EN 61000-4-6 Level 3: 0.15~80MHz, 10V, perf. Criteria A
voltage dips and interruptions
EN 50155 Class S3: 20ms interruptions, perf. Criteria A
MTBF
as per MIL-HDBK-217F, 25°C
5 Vdc output
12 Vdc output
15 Vdc output
±5 Vdc output
±12 Vdc output
±15 Vdc output
RoHS
yes
1,000
MΩ
16
pF
1,654
2,295
2,363
1,664
2,093
2,335
K
K
K
K
K
K
hours
hours
hours
hours
hours
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
100
°C
-55
125
°C
95
%
max
units
storage temperature
storage humidity
typ
non-condensing
MECHANICAL
parameter
conditions/description
min
dimensions
31.8 x 20.3 x 12.7 [1.25 × 0.80 × 0.50 inch]
weight
typ
mm
16
case material
plastic, DAP, UL 94V-0
base material
plastic, LCP, UL 94V-0
potting material
UL 94V-0
pin material
base: copper plated steel wire
plating: tin
cooling method
natural convection
cui.com
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
date 01/16/2023 │ page 4 of 9
MECHANICAL DRAWING
units: inch [mm]
pin size diameter: 0.02±0.002 inch (0.5±0.05mm)
general tolerance: inches: x.xx = ±0.02, x.xxx = ±0.010
mm: x.x = ±0.5, x.xx = ±0.25
Pin Out
cui.com
PIN
Single
outputs
Dual
outputs
1
+Vin
+Vin
2
+Vin
+Vin
3
Remote on/off
Remote on/off
11
NP
Common
12
-Vout
NP
13
+Vout
-Vout
15
NP
+Vout
23
-Vin
-Vin
24
-Vin
-Vin
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 01/16/2023 │ page 5 of 9
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 01/16/2023 │ page 6 of 9
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 01/16/2023 │ page 7 of 9
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 01/16/2023 │ page 8 of 9
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRC10W │ DESCRIPTION: DC-DC CONVERTER
date 01/16/2023 │ page 9 of 9
REVISION HISTORY
rev.
description
date
1.0
initial release
12/19/2022
1.01
safeties updated
01/16/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.