Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
12/06/2022
page
1 of 6
SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
1 W isolated output
single regulated output
3,000 Vdc isolation
continuous short-circuit protection
wide operating temperature range -40~85°C
efficiency up to 71%
designed to meet EN/BS EN 62368-1
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PRME1-S12-S5-M
12
11.4~12.6
5
20
200
1
100
69
PRME1-S12-S12-M
12
11.4~12.6
12
9
84
1
100
71
PRME1-S12-S15-M
12
11.4~12.6
15
7
67
1
100
71
PRME1-S15-S5-M
15
14.25~15.75
5
20
200
1
100
68
PRME1-S24-S5-M
24
22.8~25.2
5
20
200
1
100
69
PRME1-S24-S12-M
24
22.8~25.2
12
9
84
1
100
71
PRME1-S24-S15-M
24
22.8~25.2
15
7
67
1
100
71
Notes:
1. Measured at nominal input, 20 MHz bandwidth using the “parallel cable”. (see Application circuit).
2. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
PRME1- S XX - S XX - M
Base Number
Input Voltage
Output:
Output Voltage
S = single
cui.com
Mounting Style:
SMT
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
date 12/06/2022 │ page 2 of 6
INPUT
parameter
conditions/description
operating input voltage
12 Vdc input models
15 Vdc input models
24 Vdc input models
12 Vdc input models
current3
typ
max
units
12
15
24
12.6
15.75
25.2
Vdc
Vdc
Vdc
121/8
117/8
128/124/-
mA
mA
99/8
105/-
mA
60/4
59/4
66/64/-
mA
mA
typ
max
units
2,400
560
220
μF
μF
μF
±3
%
±0.25
%
±2
%
5 Vdc output model
all other output models
15 Vdc input models
24 Vdc input models
filter
Note:
min
11.4
14.25
22.8
5 Vdc output model
all other output models
filter capacitor
3. full load/no load
OUTPUT
parameter
conditions/description
min
maximum capacitive load
5 Vdc output models
12 Vdc output models
15 Vdc output models
voltage accuracy
at full load
line regulation
for Vin change of ±1%
load regulation
from 10% to full load
switching frequency
100% load, nominal input voltage
temperature coefficient
at full load
260
kHz
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, auto recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA
3,000
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
isolation capacitance
input to output, 100 kHz / 0.1 V
safety approvals
designed to meet 62368: EN, BS EN
conducted emissions
CISPR32/EN55032 CLASS B
radiated emissions
CISPR32/EN55032 CLASS B
ESD
IEC/EN61000-4-2 Air ±8kV, Contact ±6kV
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
yes
20
pF
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
storage humidity
non-condensing
case temperature rise
at 25°C
typ
max
units
-40
85
°C
-55
125
°C
5
95
25
%
°C
SOLDERABILITY
parameter
conditions/description
min
reflow soldering
for actual application, refer to IPC/JEDEC J-STD-020D.1
cui.com
typ
max
units
245
°C
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 12/06/2022 │ page 3 of 6
DERATING CURVES
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
date 12/06/2022 │ page 4 of 6
MECHANICAL
parameter
conditions/description
dimensions
15.24 x 11.40 x 7.25 [0.600 x 0.448 x 0.285 inch]
min
case material
black flame-retardant and heat-resistant plastic (UL94V-0)
weight
typ
units: mm [inch]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 [±0.004]
PIN CONNECTIONS
PIN
Function
1
GND
2
Vin
4
0V
5
0V
7
+Vo
10
NC
NC = Pin to be isolated from circuitry
cui.com
units
mm
1.2
MECHANICAL DRAWING
max
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
date 12/06/2022 │ page 5 of 6
APPLICATION CIRCUIT
If you want to further reduce the input and output ripple, a filter capacitor may be connected to the input and output
terminals (Figure 1) provided that the capacitance is less than the maximum capacitive load of the model, otherwise startup problems may be caused if the capacitance is too large.
Figure 1
Table 1
EMC RECOMMENDED CIRCUIT
Figure 2
Table 3
Recommended External Circuit Components
C1, C2
4.7 µF / 25 V
CY
270 pF / 3,000 Vdc
C3
refer to the Cout in Table 1
LDM
6.8 μH
cui.com
Vin
(Vdc)
Cin
(μF)
Vo
(Vdc)
Cout
(μF)
12
2.2
5
10
15
1
12
2.2
24
1
15
0.47
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRME1-M │ DESCRIPTION: DC-DC CONVERTER
date 12/06/2022 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
09/13/2021
1.01
CE certification updated
12/06/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PRME1-S15-S5-M”相匹配的价格&库存,您可以联系我们找货
免费人工找货