SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
200 W isolated output
¼-brick package with industry standard pin-out
4:1 ultra-wide input voltage range
single regulated output
high efficiency up to 91%
output short circuit, over current, over voltage, & over temperature protection
2250 Vdc isolation
EN 62368-1
available with heat sink or base plate
remote on/off control
MODEL
typ
(Vdc)
input
voltage
output
voltage
range
(Vdc)
(Vdc)
output
current
max
output
power
(A)
max
(W)
ripple
and noise1
max
efficiency2
(mVp-p)
typ
(%)
PRQ200W-Q48-S5-D
48
18~75
5
40.0
200
250
88
PRQ200W-Q48-S12-D
48
18~75
12
16.7
200
250
91
PRQ200W-Q48-S15-D
48
18~75
15
13.3
200
250
89
PRQ200W-Q48-S24-D
48
18~75
24
8.4
200
250
91
PRQ200W-Q48-S36-D3
48
18~75
36
5.56
200
300
88
PRQ200W-Q48-S48-D
48
18~75
48
4.2
200
250
91
Notes:
1. 20MHz bandwidth, nominal input, full load
2. Efficiency is measured In nominal input voltage and rated output load.
3. Model is not CE certified.
PART NUMBER KEY
PRQ200W-QXX - SXX - X - D
Packaging style
DIP
Base Number
Input Voltage
Output Voltage
cui.com
Heatsink:
"blank" = no heatsink
H = with heatsink
B = base plate
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 2 of 11
INPUT
parameter
conditions/description
operating input voltage
min
typ
max
units
18
48
80
Vdc
18
Vdc
90
Vdc
10
mA
4845/200
mA
max
units
6,000
2,000
1,000
450
μF
μF
μF
μF
start-up voltage
surge voltage
for maximum 1 second
-0.7
remote on/off (CTRL)1
module ON: CTRL pin open or pulled high (3.5~12 Vdc)
module OFF: CTRL pin pulled low to GND (0~1.2 Vdc)
input current when OFF
filter
Pi filter
current
full load/no load
2
Note: 1. The voltage of CTRL pin is relative to input pin GND.
OUTPUT
parameter
conditions/description
min
typ
maximum capacitive load
5 Vdc output models
12 Vdc & 15 Vdc output models
24 Vdc & 36 Vdc output models
48 Vdc output models
line regulation
low line to high line
±0.2
±0.5
%
load regulation
5~100% load
±0.5
±0.75
%
set-point accuracy
0~100% load
±1
±3
switching frequency
PWM mode
250
transient response
25% load step change
5 Vdc output model
all other output models
±3
±3
temperature coefficient
full load
trim range
36 Vdc output models
all other output models
100
90
sense range
%
kHz
±7.5
±5
%
%
±0.03
%/°C
110
110
%
%
105
%
PROTECTIONS
parameter
conditions/description
over voltage protection
over current protection
short circuit protection
continuous, auto recovery, hiccup
over temperature protection
36 Vdc output models
all other output models
cui.com
min
typ
max
units
110
130
160
%
110
130
150
%
95
105
115
115
120
°C
°C
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 3 of 11
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output, 5mA for 1 minute
input to case, 5mA for 1 minute
output to case, 5mA for 1 minute
min
typ
max
isolation resistance
input-output at 500 Vdc
isolation capacitance
input to output at 100 KHz/0.1 V
safety approvals
certified to 62368: EN, BS EN
conducted emmisions
CISPR32/EN55032 CLASS A (see Fig. 2 for recommended circuit)
radiated emmisions
CISPR32/EN55032 CLASS A (see Fig. 2 for recommended circuit)
ESD
IEC/EN61000-4-2, EN50121-3-2 Contact ±6KV Air ±8KV, perf. Criteria B
radiated immunity
IEC/EN61000-4-3, EN50121-3-2 10V/m, perf. Criteria A
EFT/burst
IEC/EN61000-4-4, EN50121-3-2 ±2KV, perf. Criteria A
surge
EN50121-3-2 differential mode ±1KV, 1.2/50us, sourceimpedance 42Ω, perf. Criteria B
conducted immunity
IEC/EN61000-4-6, EN50121-3-2 10 Vr.m.s, perf. Criteria A
MTBF
MIL-HDBK-217 at 25°C
RoHS
yes
2,250
1,500
500
units
Vdc
Vdc
Vdc
100
MΩ
2,200
pF
500
kHours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
max
units
see derating curve
-40
85
°C
-55
125
°C
5
95
%
wave-soldering, 10 seconds
260
°C
soldering spot is 1.5 mm away from case for 10 seconds
300
°C
storage temperature
storage humidity
non-condensing
typ
SOLDERABILITY
pin soldering resistance
temperature
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 4 of 11
MECHANICAL
parameter
conditions/description
dimensions
61.8 x 40.2 x 12.7
with base plate 62.0 x 56.0 x 14.6
with heat sink 61.8 x 40.2 x 27.7
min
case material
aluminum alloy case, black plastic bottom, flame-retardant and heat-resistant (UL94 V-0)
weight
with base plate
with heat sink
cooling method
natural convection (20 LFM)
units: mm [inches]
pin 1,2,3,5,6,7's diameter: 1.00 [0.039]
pin 4,8's diameter: 1.50 [0.059]
pin diameter tolerance: ±0.10 [±0.004]
general tolerance: ±0.50 [±0.020]
mounting hole screwing torque: Max 0.4 N·m
PIN CONNECTIONS
FUNCTION
1
+Vin
2
CTRL
3
-Vin
4
0V
5
Sense-
6
Trim
7
Sense+
8
+Vo
cui.com
max
units
mm
mm
mm
89
109
120
MECHANICAL DRAWING
PIN
typ
g
g
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
with base plate
units: mm [inches]
pin 1,2,3,5,6,7's diameter: 1.00 [0.039]
pin 4,8's diameter: 1.50 [0.059]
pin diameter tolerance: ±0.10 [±0.004]
general tolerance: ±0.50 [±0.020]
mounting hole screwing torque: Max 0.4 N·m
PIN CONNECTIONS
FUNCTION
1
+Vin
2
CTRL
3
-Vin
4
0V
5
Sense-
6
Trim
7
Sense+
8
+Vo
with heatsink
units: mm [inches]
pin 1,2,3,5,6,7's diameter: 1.00 [0.039]
pin 4,8's diameter: 1.50 [0.059]
pin diameter tolerance: ±0.10 [±0.004]
general tolerance: ±0.50 [±0.020]
mounting hole screwing torque: Max 0.4 N·m
PIN CONNECTIONS
PIN
FUNCTION
1
+Vin
2
CTRL
3
-Vin
4
0V
5
Sense-
6
Trim
7
Sense+
8
+Vo
|
PCB Footprint
date 04/04/2023 │ page 5 of 11
MECHANICAL DRAWING (CONTINUED)
PIN
3D Model
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 04/04/2023 │ page 6 of 11
DERATING CURVES
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 7 of 11
APPLICATION CIRCUIT
1. It is recommended to use the circuit shown in Fig. 1 during product testing and application, or otherwise
ensure that at least 220 µF of electrolytic capacitors are connected at the input in order to ensure adequate
voltage surge suppression and protection.
2. It is recommended to increase the value of Cin and pay attention to the unstable input voltage if the
product input side is paralleled with motor drive circuit and/or larger energy transient circuits, to ensure the
stability of input terminal and avoid repeatedly start-up problems due to input voltage lower than
under-voltage protection point.
3. It is recommended to increase the output capacitance, limited to the capactive load specification and/or
increasing the voltage clamping circuit (such as TVS) if the output terminal is inductive device such as relay or
a motor, to ensure adequate voltage surge suppression and protection.
4. Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor
values Cin and Cout and/or by selecting capacitors with a low ESR (equivalent series resistance). Also make
sure that the capacitance is not exceeding the specified maximum capacitive load value of the product.
Figure 1
Table 1
Output voltage
(Vdc)
FUSE
Cin
(µF)
5
12
15
24
20A
slow blow
Cout
(uF)
TVS
470µF
SMDJ6.0A
220µF
220µF
36
SMDJ17A
SMDJ28A
110µF
48
SMDJ14A
SMDJ47A
SMDJ54A
Note: Please pay attention to the ambient temperature of the product when using an external capacitor, increase the electrolytic
capacitor values to at least 1.5 times the original parameter if the ambient temperature is low.
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 8 of 11
EMC RECOMMENDED CIRCUITS
Figure 2
Table 2
List of Components
Recommended Component value
C1
150µF/100V electrolytic capacitor
C9
47µF/100V electrolytic capacitor
C2, C3, C4, C5, C6, C7, C8
2.2µF/100V ceramic capacitor
L1
2.0mH
L2
1.5µF/15A inductance
CY1, CY2, CY3, CY4
1nF Y1 safety capacitor
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 9 of 11
APPLICATION NOTES
Figure 3
Table 3
VNOM
RTOP
RBOTTOM
RO
VREF
(Vdc)
(kΩ)
(kΩ)
(kΩ)
(V)
5
3.036
3.0
10
2.5
12
11.0
2.87
15
2.5
15
14.03
2.8
15
2.5
24
24.872
2.87
15
2.5
36
38.73
2.85
15
2.5
48
53.017
2.913
15
2.5
Note:
Note:
Value for RTOP, RBOTTOM, RO, and VREF refer to Table 3 (fixed internal values).
RTRIM: Trim resistance
a: User-defined parameter, no actual meanings
VNOM: Nominal output voltage
VOUT: Target output voltage
When using the Trim down function make sure that the RT resistor value is calculated correctly. If the Trim pin is shorted with + Vo, or its value is too low,
the or the output voltage Vo’ would be lower than 0.9Vo, which may cause the product to fail.
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 04/04/2023 │ page 10 of 11
REMOTE SENSE APPLICATION
Figure 4
Note:
1. Lines must be kept as short as possible.
2. If the sense function is not used for remote regulation the user must connect the +Sense to +Vo and -Sense to 0V at the DC-DC converter
pins and will compensate for voltage drop across pins only.
3. The connections between Sense lines and their respective power lines must be kept as short as possible, otherwise they may be picking
up noise, interference and/or causing unstable operation of the power module.
Figure 5
Note:
1. In cables and discrete wiring applications, twisted pair or other techniques should be implemented.
2. PCB-tracks or cables/wires for Remote Sense must be kept as short as possible. Twisted pair or shielded wires are suggested for remote
compensation and must be kept as short as possible.
3. We recommend using adequate cross section for PCB-track layout and/or cables to connect the power supply module to the load in
order to keep the voltage drop below 0.3V and to make sure the power supply's output voltage remains within the specified range
4. Note that large wire impedance may cause oscillation of the output voltage and/or increased ripple. Consult technical support or factory for further
advice of sense operation.
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ200W │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2023 │ page 11 of 11
REVISION HISTORY
rev.
description
date
1.0
initial release
10/25/2021
1.01
pin connections tables updated
04/04/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.