Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
07/15/2021
page
1 of 7
SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
ultra-wide 4:1 input range
dual positive output with asymmetrical options
3000 Vdc isolation
input under-voltage protection
output short circuit and over current protection
wide operating temp: -40°C to +85°C
EN62368 approved
MODEL
output
voltage
output
current
max
max
ripple
and noise1
max
(Vdc)
Vo1/Vo2
(Vdc)
Vo1/Vo2
(A)
(W)
Vo1/Vo2
(mVp-p)
min
(%)
typ
(%)
PRQ3W-Q48-D55-S
18~75
5/5
300/300
3
150/150
76
78
PRQ3W-Q48-D512-S
18~75
5/12
300/125
3
150/150
76
78
PRQ3W-Q48-D524-S
18~75
5/24
300/63
3
150/150
76
78
Notes:
input
voltage
range
output
power
1. 20MHz bandwidth, nominal input, full load
2. Efficiency is measured In nominal input voltage and rated output load.
PART NUMBER KEY
PRQ3W-QXX - DXXX - S
Base Number
Input Voltage
cui.com
Output Voltage
efficiency2
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 2 of 7
INPUT
parameter
conditions/description
input voltage
filter
capacitance filter
current
full load/no load
min
typ
max
units
18
48
80
Vdc
83/12
mA
max
units
680
330
220
μF
μF
μF
OUTPUT
parameter
conditions/description
output capacitance
5V outputs
12V outputs
24V outputs
min
typ
line regulation
low line to high line
Vo1
Vo2
±0.2
±0.5
±0.5
±1.0
%
load regulation
10~100% load
Vo1
Vo2
±0.5
±1.1
±1.0
±2.0
%
set-point accuracy
Vo1 / Vo2
10~100% load
5~10% load
±1/ ±3
±2/ ±4
±3/±5
±4/ ±6
%
%
start-up time
nominal input and constant resistance load
10
switching frequency
300
transient response
temperature coefficient
ms
full load
kHz
±8
500
% Vout
µs
±0.03
%/°C
max
units
250
%Io
PROTECTIONS
parameter
conditions/description
min
over current protection
short circuit protection
110
output shutdown, auto recovery
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 3 of 7
SAFETY AND COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output
output to output
3000
1500
typ
max
Vdc
Vdc
isolation resistance
input-output resistance at 500 Vdc
1000
MΩ
isolation capacitance
input-output capacitance at 100 KHz/0.1 V
safety approvals
EN/IEC 62368
EMI/EMC
EN 55032: 2015 Class B (see recommended circuit)
ESD
IEC/EN61000-4-2, Contact ±4KV, perf. Criteria B
radiated immunity
IEC/EN61000-4-3, 10 v/m, perf. Criteria A
EFT/burst
IEC/EN61000-4-4, ±2KV (see recommended circuit), perf. Criteria B
surge
IEC/EN61000-4-5, line to line ±2KV (see recommended circuit), perf. Criteria B
conducted immunity
IEC/EN61000-4-6, 3 Vr.m.s, perf. Criteria A
RoHS
yes
MTBF
MIL-HDBK-217@25°C
1000
units
pF
1000
kHours
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
operating temperature
-40
85
°C
storage temperature
-55
125
°C
5
95
%
humidity
non-condensing
shock/vibration
10-150Hz, 5G, 0.75mm. along X, Y and Z
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
27.40 x 9.50 x 12.00
min
case material
Black flame-retardant and heat-resistant plastic (UL94 V-0)
typ
5.4
MECHANICAL DRAWING
units: mm [inches]
tolerance: ± 0.50 [±0.020]
PIN CONNECTIONS
FUNCTION
1
GND
2
Vin
6
+Vo1
7
-Vo1
8
CS*
9
-Vo2
10
+Vo2
units
mm
weight
PIN
max
* Connecting a low ESR capacitor between CS & pin 7 may
reduce output ripple & noise. Maximum value = 47 µF
cui.com
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 5 of 7
DERATING CURVES
Figure 1
APPLICATION CIRCUIT
All the dc-dc converters of this series are tested before delivery using the recommended circuit shown in Fig. 2.
Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor values Cin and Cout
and/or by selecting capacitors with a low ESR (equivalent series resistance). Also make sure that the capacitance is not exceeding
the max. capacitive load value of the product.
Figure 2
Table 1
output voltage (Vdc)
Cin (uF)
5
47
12
22
24
22
cui.com
Cout (uF)
100
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 6 of 7
EMC RECOMMENDED CIRCUITS
Figure 3
Table 2
List of Components
Model
Vin:48V
FUSE
Choose according to actual input current
C0
680µF/100V
C1/C5/C6
4.7µF/100V
C2
330µF/100V
C3/C4
Refer to the Cout in Fig.2
LDM1
22µH/0.6A
CY1/CY2/CY4
1nF/3kV
CY3
2.2nF/3kV
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PRQ3W-S │ DESCRIPTION: DC-DC CONVERTER
date 07/15/2021 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
05/26/2020
1.01
derating curve and circuit figures updated
07/15/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PRQ3W-Q48-D524-S”相匹配的价格&库存,您可以联系我们找货
免费人工找货