Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
02/08/2023
page
1 of 6
SERIES: PSK-4 │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
universal input range from 85~305 Vac, 120~431 Vdc
high efficiency up to 82%
no load power 95% Reduction, perf. Criteria A
voltage interruption
IEC 61000-4-11:2020, >95% Reduction, perf. Criteria B
MTBF
per MIL-HDBK-217F at 25 °C
RoHS
yes
max
units
3,000
Vac
2,200,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
(see derating curve)
storage temperature
storage humidity
DERATING CURVES
cui.com
typ
max
units
-40
80
°C
-40
85
°C
0
95
%
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PSK-4 │ DESCRIPTION: AC-DC POWER SUPPLY
3D Model
|
PCB Footprint
date 02/08/2023 │ page 4 of 6
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/08/2023 │ page 5 of 6
MECHANICAL
parameter
conditions/description
dimensions
1.62 x 0.83 x 0.787 [41.1 x 21.0 x 20.00 mm]
min
weight
shock
Meet MIL-STD-810F table 516.5, table 516.5-1 10ms,
each axis 3 times (±X·±Y·±Z axis)
vibration
Meet MIL-STD-810F table 514.5CVIII, 15~2000Hz, X·Y·Z axis,
1 hour (each axis), total 3 hrs
MECHANICAL DRAWING
units: inches: x.xx = ±0.03, x.xxx = ±0.020
mm: x.x = ±0.7, x.xx = ±0.50
PIN CONNECTIONS
PIN
Function
1
AC (N)
2
AC (L)
3
+Vout
4
-Vout
cui.com
typ
max
units
inch
30
g
75
g
4
g
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/08/2023 │ page 6 of 6
REVISION HISTORY
rev.
1.0
description
date
initial release
02/08/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“PSK-4-24”相匹配的价格&库存,您可以联系我们找货