0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PSK-45-15-DIN

PSK-45-15-DIN

  • 厂商:

    CUI

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 15V 45W

  • 数据手册
  • 价格&库存
PSK-45-15-DIN 数据手册
Additional Resources: Product Page | 3D Model date 06/03/2022 page 1 of 7 SERIES: PSK-45 │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES • • • • • universal input voltage range (85~264 VAC) IEC/EN/UL 62368 certified meets CISPR32/EN 55032 Class B without external components 4,000 VAC isolation rating short-circuit, over-current, over-voltage protections MODEL output voltage output current output power ripple and noise efficiency (Vdc) max (A) max (W) max (mVp-p) typ (%) 5 8.0 40 120 81 PSK-45-12 12 3.8 45 120 84 PSK-45-15 15 3.0 45 120 85 PSK-45-24 24 1.9 45 120 86 PSK-45-48 48 0.94 45 120 87 PSK-45-5 PART NUMBER KEY PSK-45 - XX- X Base Number Output Voltage Mounting Style blank = board mount T = chassis mount DIN = DIN-rail mount cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY date 06/03/2022 │ page 2 of 7 INPUT parameter conditions/description min max units voltage ac input dc input 85 100 264 370 Vac Vdc 47 63 Hz 1.5 0.75 A frequency current typ at 115 Vac at 230 Vac inrush current at 115 Vac at 230 Vac no load power consumption at 230 Vac 50 70 A 0.5 W max units 30,000 6,400 5,600 2,000 600 μF OUTPUT parameter conditions/description capacitive load 5 Vdc output 12 Vdc output 15 Vdc output 24 Vdc output 48 Vdc output min initial set point accuracy at full load ±2 % line regulation rated load ±0.5 % load regulation 0%~100% load ±1.0 % hold-up time at 115 Vac at 230 Vac 8 50 ms ±0.02 %/°C temperature coefficient typ PROTECTIONS parameter conditions/description min over voltage protection 5 Vdc output, clamp or hiccup 12 Vdc output, clamp or hiccup 15 Vdc output, clamp or hiccup 24 Vdc output, clamp or hiccup 48 Vdc output, clamp or hiccup over current protection auto recovery short circuit protection hiccup, continuous, auto recovery typ max units 9 16 24 35 56 V 110 % SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output min typ max safety approvals UL/cUL, EN, IEC 62368 safety class Class II EMI/EMC CISPR 32/EN 55032 Class B ESD IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV, perf. Criteria B radiated immunity IEC/EN 61000-4-3 10 V/m, perf. Criteria A EFT/burst IEC/EN 61000-4-4 ±4KV, perf. Criteria B surge IEC/EN 61000-4-5 line to line +/-2kV/line to ground +/-4kV (see recommended EMC circuit) IEC/EN 61000-4-5 line to line +/-1kV perf. Criteria B conducted immunity IEC/EN 61000-4-6 10 Vr.m.s, perf. Criteria A voltage dips and interruption IEC/EN 61000-4-11 0%, 70%, perf. Criteria B MTBF per MIL-HDBK-217F at 25 °C RoHS yes 4,000 300,000 cui.com units Vac hours Additional Resources: Product Page CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY | 3D Model date 06/03/2022 │ page 3 of 7 DERATING CURVE EFFICIENCY CURVES cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY date 06/03/2022 │ page 4 of 7 ENVIRONMENTAL parameter max units operating temperature conditions/description min -40 70 °C storage temperature -40 85 °C 0 95 % storage humidity typ SOLDERABILITY parameter conditions/description max units wave soldering 5~10 seconds (± 5 °C) min typ 260 °C manual welding 3~5 seconds (± 10 °C) 360 °C max units MECHANICAL parameter conditions/description min dimensions 87.00 x 52.00 x 29.50 (board mount) 135.00 x 70.00 x 37.90 (chassis mount) 137.00 x 70.00 x 42.40 (DIN-rail) weight board mount chassis mount DIN-rail cooling free air convection case material black plastic, flame-retardant and heat-resistant (UL94V-0) units: mm [inch] pin diameter tolerance: ± 0.1 [±0.004] PIN CONNECTIONS Function 1 AC(L) 2 AC(N) 3 +Vo 4 -Vo mm mm mm 205 290 360 MECHANICAL DRAWING (BOARD MOUNT) PIN typ cui.com g g g Additional Resources: Product Page CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY units: mm [inch] tolerance: ± 1.00 [±0.040] wire range: 24 - 12 AWG tightening torque: 0.4 N·m PIN CONNECTIONS Function 1 AC(L) 2 NC 3 AC(N) 4 +Vo 5 -Vo 6 NC 7 NC 8 NC MECHANICAL DRAWING (DIN-RAIL MOUNT) units: mm [inch] tolerance: ± 1.00 [±0.040] wire range: 24 - 12 AWG tightening torque: 0.4 N·m installed on DIN-RAIL TS35 PIN CONNECTIONS PIN Function 1 AC(L) 2 NC 3 AC(N) 4 +Vo 5 -Vo 6 NC 7 NC 8 NC 3D Model date 06/03/2022 │ page 5 of 7 MECHANICAL DRAWING (CHASSIS MOUNT) PIN | cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY date 06/03/2022 │ page 6 of 7 APPLICATION CIRCUIT Figure 1 Table 1 Recommended External Circuit Components Part no. C1 C2 FUSE PSK-45-5 680 μF PSK-45-12 220 μF PSK-45-15 1 μF 220 μF PSK-45-24 120 μF PSK-45-48 100 μF MOV TVS SMBJ7.0A 3.15A/250V, slow-blow SMBJ20A S14K350 SMBJ20A SMBJ30A SMBJ64A EMC RECOMMENDED CIRCUIT Figure 2 Table 2 Component Reccomended value FUSE 3.15A/250V, slow-blow, required MOV1 S20K300 MOV2/MOV3 S10K300 GDT EM3600XS CX 0.22 μF/ 275 Vac CY1, CY2 1 nF / 400 Vac R1 1 MΩ / 1 W LDM 4.7 uH LCM 2 mH cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY date 06/03/2022 │ page 7 of 7 REVISION HISTORY rev. description date 1.0 initial release 07/13/2020 1.01 figure and circuit drawings updated 03/25/2021 1.02 UKCA mark added 06/03/2022 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PSK-45-15-DIN 价格&库存

很抱歉,暂时无法提供与“PSK-45-15-DIN”相匹配的价格&库存,您可以联系我们找货

免费人工找货