Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
09/13/2022
page
1 of 7
SERIES: PSK-5W │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
wide input range (85~305 Vac)
UL/EN/IEC 62368 certified
meets CISPR32/EN 55032 Class B without external components
short-circuit, over-current, over-voltage protections
MODEL
PSK-5W-31,2,3
output
voltage
output
current
output
power
ripple
and noise
efficiency
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
3.3
1.25
4.2
100
70
PSK-5W-5
5
1.0
5
100
76
PSK-5W-91,2,3
9
0.55
5
100
74
1,2
1,2,3
PSK-5W-12
12
0.42
5
100
77
PSK-5W-151,2,3
15
0.333
5
100
77
PSK-5W-24
24
0.23
5.5
100
80
1,2,3
Note:
1. Discontinued model - board mount option.
2. Discontinued model - chassis mount option.
3. Discontinued model - DIN-rail mount option.
PART NUMBER KEY
PSK - 5W - XX - X
Base Number
Output Voltage
cui.com
Mounting Style:
blank = board mount
T = chassis mount
DIN = DIN-rail mount
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/13/2022 │ page 2 of 7
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
85
100
305
430
Vac
Vdc
47
63
Hz
0.15
0.10
A
A
frequency
current1
115 Vac
230 Vac
inrush current
115 Vac
230 Vac
typ
10
20
leakage current
A
A
5
mA
max
units
4,000
4,000
1,000
820
820
470
μF
Note 1: Recommended input fuse - 1A/300V, slow blow
OUTPUT
parameter
conditions/description
capacitive load
3.3 Vdc
5 Vdc
9 Vdc
12 Vdc
15 Vdc
24 Vdc
output voltage accuracy
3.3 V
all other models
line regulation
min
typ
±3
±2
%
%
rated load
±0.5
%
load regulation
0~100% load
±1.0
%
hold-up time
115 Vac input
230 Vac input
8
60
ms
ms
100
kHz
switching frequency
PROTECTIONS
parameter
conditions/description
min
over voltage protection
3.3/5 Vdc output
9 Vdc output
12/15 Vdc output
24 Vdc output
over current protection
self recovery
short circuit protection
output shutdown, auto recovery
typ
max
units
7.5
15
20
30
V
V
V
V
110
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
for 1 minute, 5mA
safety approvals
UL/EN/IEC 62368
safety class
Class II
EMI/EMC
CISPR32/EN55032: Class B (no external components required)
ESD
IEC/EN 61000-4-2: Contact ±6KV/ Air ±8KV, perf. Criteria B
radiated immunity
IEC/EN 61000-4-3: 10V/m, perf. Criteria A
EFT/burst
IEC/EN 61000-4-4: ±2KV, perf. Criteria B
IEC/EN 61000-4-4: ±4KV, perf. Criteria B, see recommended EMC circuit
surge
IEC/EN 61000-4-5: line to line ±1KV, perf. Criteria B
IEC/EN 61000-4-5: line to line ±2kV, line to ground ±4kV, perf. Criteria B, see recommended EMC circuit
conducted immunity
IEC/EN 61000-4-6: 10Vr.m.s, perf. Criteria A
voltage dips
IEC/EN 61000-4-11: 0%, 70%
MTBF
MIL-HDBK-217F@25°C
RoHS
yes
4,000
300,000
cui.com
max
units
Vac
hours
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/13/2022 │ page 3 of 7
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-40
70
°C
storage temperature
-40
85
°C
0
95
%
max
units
260
°C
360
°C
max
units
storage humidity
typ
SOLDERABILITY
parameter
conditions/description
min
typ
wave soldering
hand soldering
3~5 seconds max
MECHANICAL
parameter
conditions/description
dimensions
DIP: 50.80 x 25.40 x 15.36
chassis mount: 76.00 x 31.50 x 24.16
DIN rail: 76.00 x 31.50 x 28.76
min
weight
DIP
chassis mount
DIN rail
case material
Black plastic, flame-retardant and heat-resistant (UL94V-0)
units: mm [inch]
tolerance: ±0.50 [±0.020]
PIN CONNECTIONS
Function
1
AC(N)
2
AC(L)
3
-Vo
4
+Vo
mm
mm
mm
31
52
70
MECHANICAL DRAWING (BOARD MOUNT)
PIN
typ
cui.com
g
g
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
units: mm [inch]
tolerance: ±0.50 [±0.020]
wire range: 24~12 AWG
tightening torque:Max 0.4 N·m
PIN CONNECTIONS
Function
1
AC(N)
2
AC(L)
3
-Vo
4
+Vo
MECHANICAL DRAWING (DIN-RAIL MOUNT)
units: mm [inch]
tolerance: ±0.50 [±0.020]
wire range: 24~12 AWG
tightening torque:Max 0.4 N·m
mounting rail: TS35, rail needs to
connect safety ground
PIN CONNECTIONS
PIN
Function
1
AC(N)
2
AC(L)
3
-Vo
4
+Vo
|
PCB Footprint
date 09/13/2022 │ page 4 of 7
MECHANICAL DRAWING (CHASSIS MOUNT)
PIN
3D Model
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/13/2022 │ page 5 of 7
TYPICAL APPLICATION CIRCUIT
Output Filter Components:
We recommend using an electrolytic capacitor with high frequency, and low ESR rating for C2 (refer to manufacture’s datasheet). Choose
a Capacitor voltage rating with at least 20% margin, in other words not exceeding 80%. C1 is a ceramic capacitor used for filtering highfrequency noise and TVS is a recommended suppressor diode to protect the application in case of a converter failure.
Figure 1
Table 1
Part No.
C1(µF)
C2(µF)
PSK-5W-3
220
PSK-5W-5
220
PSK-5W-9
PSK-5W-12
FUSE
TVS
SMBJ7A
SMBJ7A
1A/300V,
slow-blow,
required
100
1
MOV
100
S14K350
SMBJ12A
SMBJ20A
PSK-5W-15
100
SMBJ20A
PSK-5W-24
47
SMBJ30A
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Components
Recommended Value
MOV
S14K350
CX
0.1µF/310VAC
L1
4.7uH/2.0A
CY1
1nF/400VAC
CY2
1nF/400VAC
LCM
2.2mH
FUSE
2A/300V, slow-blow, required
R0
33Ω/3W
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
3D Model
|
PCB Footprint
date 09/13/2022 │ page 6 of 7
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-5W │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/13/2022 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
06/29/2020
1.01
mechanical drawings updated
12/03/2020
1.02
figure and circuit drawings updated
02/24/2021
1.03
discontinued models PSK-5W-3, PSK-5W-9, PSK-5W-12,
PSK-5W-15, PSK-5W-3-T, PSK-5W-12-T, PSK-5W-15-T, PSK-5W-3-DIN,
PSK-5W-5-DIN, PSK-5W-12-DIN, PSK-5W-15-DIN, PSK-5W-24-DIN
07/01/2022
1.04
discontinued models PSK-5W-3-DIN, PSK-5W-5, PSK-5W-5-T,
PSK-5W-9-T, PSK-5W-9-DIN, PSK-5W-24, PSK-5W-24-T
09/13/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.