0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PSK-S12B-24

PSK-S12B-24

  • 厂商:

    CUI

  • 封装:

    DIP4 模块

  • 描述:

    封闭式 AC DC 转换器 1 输出 24V 500mA 90 ~ 264 VAC,120 ~ 370 VDC 输入

  • 数据手册
  • 价格&库存
PSK-S12B-24 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 02/25/2021 page 1 of 6 SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • universal input range (90 ~ 264 Vac) Class B emissions (EN55032/CISPR/FCC) certified to IEC/EN/UL 62368-1 designed to meet IEC/EN 60335 short circuit protection over voltage protection < 75 mW no-load power consumption Class II MODEL PSK-S12B-5 PSK-S12B-9 output voltage output current output power ripple and noise1 efficiency2 (Vdc) min (A) max (A) max (W) max (mVp-p) typ (%) 5 0 2.0 10 100 80 9 0 1.34 12 100 85 PSK-S12B-12 12 0 1.0 12 120 85 PSK-S12B-15 15 0 0.8 12 150 85 PSK-S12B-24 24 0 0.5 12 240 87 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output. 2. At 230 Vac, full load, 25°C. 3. All specifications are measured at Ta=25°C, nominal input voltage, and 75% rated output load unless otherwise specified. PART NUMBER KEY PSK-S12B - XX Base Number Output Voltage cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY date 02/25/2021 │ page 2 of 6 INPUT parameter conditions/description min voltage frequency current at 100 Vac, full load inrush current at 240 Vac, cold start, 25°C leakage current at 264 Vac max units 90 120 typ 264 370 Vac Vdc 47 63 Hz 400 mA 50 A 0.25 mA OUTPUT parameter conditions/description capacitive load 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models initial set point accuracy line regulation load regulation min typ max units 2,000 1,340 1,000 800 500 μF μF μF μF μF at 100% load ±2 % measured at high line to low line at full load ±1 % measured at 10%~100% load ±1 % 3 s start-up time hold-up time at 115 Vac switching frequency temperature coefficient 10 ms 65 kHz ±0.05 %/°C PROTECTIONS parameter conditions/description over voltage protection hiccup, auto recovery 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models short circuit protection hiccup, auto recovery min typ max units 6.3 12.6 15.8 18.9 31.5 Vdc Vdc Vdc Vdc Vdc max units SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute min isolation resistance 3,000 Vac 100 MΩ safety approvals certified to IEC/EN/UL 62368-1 designed to meet IEC/EN 60335 safety class Class II conducted emissions EN55032 2015, EN61000-6-3 2007+A1: 2011+AC: 2012, Class B, 47 CFR FCC Part 15 Subpart B (Class B) radiated emissions EN55032 2015, EN61000-6-3 2007+A1: 2011+AC: 2012, Class B, 47 CFR FCC Part 15 Subpart B (Class B) harmonic current emissions EN61000-3-2:2014 voltage fluctuations & flicker EN61000-3-3:2013 ESD IEC61000-4-2:2008 radiated immunity IEC61000-4-3:2010 EFT/burst IEC61000-4-4:2012 surge IEC61000-4-5:2014 cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY date 02/25/2021 │ page 3 of 6 SAFETY & COMPLIANCE (CONTINUED) parameter conditions/description conducted immunity IEC61000-4-6:2013 power frequency magnetic field IEC61000-4-8:2009 voltage dips & interruptions IEC61000-4-11:2004 MTBF as per MIL-HDBK-217F, at 115 Vac, 25°C, GB 5 Vdc output model 9 Vdc output model 12 Vdc output model 15 Vdc output model 24 Vdc output model RoHS Notes: min typ max 580,000 870,000 660,000 740,000 620,000 units hours hours hours hours hours yes 4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curves -40 75 °C -40 85 °C 93 % 5,000 m storage temperature operating humidity typ non-condensing altitude vibration as per MIL-STD-810F Table 514.5C-VIII; 15~2000 Hz for 1 hour on each axis for 3 hours 4 G shock as per MIL-STD-810F Table 516.5, Table 516.5-1; for 10 ms on each axis 3 times 75 G DERATING CURVE cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY date 02/25/2021 │ page 4 of 6 MECHANICAL parameter conditions/description dimensions 1.600 x 1.100 x 0.772 (40.64 x 27.94 x 19.60 mm) min weight typ units: inch [mm] tolerance: ±0.020[±0.50] PIN CONNECTIONS PIN Function 1 AC (N) 2 AC (L) 3 -Vo 4 +Vo cui.com units inches 40 MECHANICAL DRAWING max g Additional Resources: Product Page | CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY 3D Model | PCB Footprint date 02/25/2021 │ page 5 of 6 INSTALLATION INSTRUCTIONS The mounting holes should all be 1.5 mm in diameter. A minimum of 4 mm clearance is required for all four sides of the unit and a minimum of 5 mm clearance is required above the top surface of the unit. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY date 02/25/2021 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 02/13/2020 1.01 derating curve drawing updated 02/25/2021 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PSK-S12B-24 价格&库存

很抱歉,暂时无法提供与“PSK-S12B-24”相匹配的价格&库存,您可以联系我们找货

免费人工找货