SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
100 W isolated output
ultra-wide 14:1 input range, 12~160 Vdc
-40 ~ 105 °C operating temperature with derating
reinforced insulation
input under-voltage; output over temperature, over current, & over voltage protection
4,200 Vdc isolation
remote on/off
industry standard 1/4 brick package
UL/EN/IEC 62368 certified
meets EN 55032/55035/50155/EN 45545-2 with external circuits
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
& noise1
efficiency2
nom
(Vdc)
range
(Vdc)
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
PVQ100W-O72-S5-D
72
12~160
5
20
100
150
87.5
PVQ100W-O72-S12-D
72
12~160
12
8.3
100
150
88
PVQ100W-O72-S15-D
72
12~160
15
6.7
100
150
89
PVQ100W-O72-S24-D
72
12~160
24
4.2
100
240
89
PVQ100W-O72-S28-D
72
12~160
28
3.6
100
240
90
PVQ100W-O72-S54-D
72
12~160
54
1.85
100
480
90
Notes:
1. 20MHz bandwidth, peak to peak, 10µF polymer tantalum and 1µF ceramic capacitors.
2. Efficiency is measured at 72 Vdc input voltage.
3. An external input capacitor 220µF for all models is recommended to reduce input ripple voltage.
PART NUMBER KEY
PVQ100W - OXX - SXX X - D X
Base Number
Input Voltage
Output voltage
Remote ON/OFF Logic:
"none" = Positive
N = Negative
cui.com
Mounting Style: Mounting inserts:
D = DIP
"blank" = M3x0.5 mounting inserts
C = clear screw inserts (Ø3.2 mm)
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
date 04/17/2023 │ page 2 of 9
INPUT
parameter
conditions/description
operating input voltage
under voltage lockout
min
typ
max
units
12
72
160
Vdc
turn-on voltage
treshold
80% load
10.7
11
11.7
Vdc
turn-off voltage
treshold
80% load
9.7
10
10.7
Vdc
lockout hysteresis
voltage
80% load
1.0
Vdc
current
at 16 V input, full load
at 12 V input, 80% load
8.0
A
inrush current (I2t)
as per ETS300 132-2
0.1
A2s
filter
Pi filter
surge voltage
for maximum of 100ms
185
Vdc
1
mA
30
µA
positive logic
CTRL
negative logic
on/off current4
models OFF (on/off pin 0~1.2 Vdc)
models ON (on/off pin 0~1.2 Vdc)
models OFF (3.5~160 Vdc or on/off pin open circuit)
I on/off at V on/off = 0V
leakage current
4
Notes:
models ON (3.5~160 Vdc or on/off pin open circuit)
0.4
logic high, V on/off = 15V
4. For both remote on/off logic.
OUTPUT
parameter
conditions/description
maximum capacitive load
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
28 Vdc output model
54 Vdc output model
voltage accuracy
at 72 V input, full load, 25°C
line regulation
load regulation
temperature coefficient
-40° ~ 105°C
min
typ
max
units
20,000
8,300
6,700
4,200
3,600
1,000
μF
μF
μF
μF
μF
μF
1.0
%
from low line to high line, full load
±0.2
%
full load to no load
±0.2
%
±0.02
%/°C
220
kHz
-1.0
switching frequency
180
200
transient recovery time
75 ~ 100% of step load change, di/dt = 0.1A/µs
(within 1% Vout nominal)
250
μs
transient response deviation
75 ~ 100% of step load change, di/dt = 0.1A/µs
(within 1% Vout nominal)
±5
%
start up time / input voltage
V on/off to 10% Vo_set, remote on
50
ms
start up time / on/off control
Vin_min to 10% Vo_set, power up
50
ms
rise time
10% Vo_set to 90% Vo_set
50
ms
adjustability
Po ≤ max rated power, Io ≤ Io_max
54 Vdc output model
all other models
remote sense
Po ≤ max rated power, Io ≤ Io_max % of nominal Vo
54 Vdc output model
all other models
cui.com
-20
-20
10
15
%
%
10
15
%
%
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
date 04/17/2023 │ page 3 of 9
PROTECTIONS
parameter
conditions/description
min
typ
max
units
over voltage protection
limited voltage, % of nominal output
54 Vdc output model
all other models
112
117
117
125
140
140
%
%
over current protection
auto recovery, hiccup
110
150
180
%
short circuit protection
continuous, auto recovery
over temperature protection
temperature at the center part of case, non-latching
shutdown
recovery
110
100
°C
°C
SAFETY AND COMPLIANCE
parameter
isolation voltage
conditions/description
min
typ
max
units
input to output, for 1 minute
3,000
4,200
Vac
Vdc
input to case (base plate), for 1 minute
2,100
3,000
Vac
Vdc
output to case (base plate), for 1 minute
1,500
2,100
Vac
Vdc
isolation resistance
input to output
isolation capacitance
input to output
100
MΩ
safety approvals
certified to 62368: UL/cUL, EN, IEC
concucted emissions
EN55032 and EN50155 Compliant (with external filter)
ESD
EN61000-4-2 Level 3: Air ±8kV, Contact ±6kv, perf. Criteria A
radiated immunity
EN61000-4-3 Level 3: 80~ 1000 MHz, 20V/m, perf. Criteria A
EFT/burst
EN61000-4-4 Level 3: on power input port, ±2kV, external input capacitor required (EN 50155),
perf. Criteria A
surge
EN61000-4-5 Level 4: Line to Earth, ±4kV, Line to Line ±2kV (EN50155), perf. Criteria A
conducted immunity
EN61000-4-6 Level 3: 0.15~80MHz, 10V, perf. Criteria A
voltage supply interruptions
EN50155 Class S3: 20ms interruptions
MTBF
as per MIL-HDBK-217F, 25°C
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
28 Vdc output model
54 Vdc output model
RoHS
yes
1,000
pF
570
690
785
840
800
850
K hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating case temperature
measured at the center of the case plate,
see derating curve
-40
105
°C
-55
125
°C
95
%
storage temperature
operating humidity
non-condensing
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
date 04/17/2023 │ page 4 of 9
MECHANICAL
parameter
conditions/description
dimensions
57.9 × 36.8 × 12.8 [2.28 x 1.45 x 0.50 inch]
min
case material
plastic, DAP, UL 94V-0
weight
units: inch [mm]
tolerances: inches: x.xx = ±0.02, x.xxx = ±0.010
ii
mm: x.x = ±0.5, x.xx = ±0.25
PIN Out
Function
1
+Vin
2
on/off
3
-Vin
4
-Vo
5
Sense-
6
Trim
7
Sense+
8
+Vo
cui.com
max
units
mm
66
MECHANICAL DRAWING
PIN
typ
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 04/17/2023 │ page 5 of 9
DERATING CURVES
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 04/17/2023 │ page 6 of 9
EFFICIENCY CURVES
cui.com
Additional Resources:
Product Page
|
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
3D Model
|
PCB Footprint
date 04/17/2023 │ page 7 of 9
EFFICIENCY CURVES (CONTINUED)
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
|
PCB Footprint
date 04/17/2023 │ page 8 of 9
EFFICIENCY CURVES (CONTINUED)
Efficiency measured at 100% load. At 80% load when Vin is 12 ~ 16V.
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER
date 04/17/2023 │ page 9 of 9
REVISION HISTORY
rev.
description
date
1.0
initial release
11/22/2022
1.01
clear mounting insert option added
12/12/2022
1.02
PN key updated
04/17/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.