PVQ100W-O72-S5-D

PVQ100W-O72-S5-D

  • 厂商:

    CUI

  • 封装:

    DIP8 模块

  • 描述:

    隔离模块 直流转换器 1 输出 5V 20A 12V - 160V 输入

  • 数据手册
  • 价格&库存
PVQ100W-O72-S5-D 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 04/17/2023 page 1 of 9 SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • • 100 W isolated output ultra-wide 14:1 input range, 12~160 Vdc -40 ~ 105 °C operating temperature with derating reinforced insulation input under-voltage; output over temperature, over current, & over voltage protection 4,200 Vdc isolation remote on/off industry standard 1/4 brick package UL/EN/IEC 62368 certified meets EN 55032/55035/50155/EN 45545-2 with external circuits MODEL input voltage output voltage output current output power ripple & noise1 efficiency2 nom (Vdc) range (Vdc) (Vdc) max (A) max (W) max (mVp-p) typ (%) PVQ100W-O72-S5-D 72 12~160 5 20 100 150 87.5 PVQ100W-O72-S12-D 72 12~160 12 8.3 100 150 88 PVQ100W-O72-S15-D 72 12~160 15 6.7 100 150 89 PVQ100W-O72-S24-D 72 12~160 24 4.2 100 240 89 PVQ100W-O72-S28-D 72 12~160 28 3.6 100 240 90 PVQ100W-O72-S54-D 72 12~160 54 1.85 100 480 90 Notes: 1. 20MHz bandwidth, peak to peak, 10µF polymer tantalum and 1µF ceramic capacitors. 2. Efficiency is measured at 72 Vdc input voltage. 3. An external input capacitor 220µF for all models is recommended to reduce input ripple voltage. PART NUMBER KEY PVQ100W - OXX - SXX X - D X Base Number Input Voltage Output voltage Remote ON/OFF Logic: "none" = Positive N = Negative cui.com Mounting Style: Mounting inserts: D = DIP "blank" = M3x0.5 mounting inserts C = clear screw inserts (Ø3.2 mm) Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER date 04/17/2023 │ page 2 of 9 INPUT parameter conditions/description operating input voltage under voltage lockout min typ max units 12 72 160 Vdc turn-on voltage treshold 80% load 10.7 11 11.7 Vdc turn-off voltage treshold 80% load 9.7 10 10.7 Vdc lockout hysteresis voltage 80% load 1.0 Vdc current at 16 V input, full load at 12 V input, 80% load 8.0 A inrush current (I2t) as per ETS300 132-2 0.1 A2s filter Pi filter surge voltage for maximum of 100ms 185 Vdc 1 mA 30 µA positive logic CTRL negative logic on/off current4 models OFF (on/off pin 0~1.2 Vdc) models ON (on/off pin 0~1.2 Vdc) models OFF (3.5~160 Vdc or on/off pin open circuit) I on/off at V on/off = 0V leakage current 4 Notes: models ON (3.5~160 Vdc or on/off pin open circuit) 0.4 logic high, V on/off = 15V 4. For both remote on/off logic. OUTPUT parameter conditions/description maximum capacitive load 5 Vdc output model 12 Vdc output model 15 Vdc output model 24 Vdc output model 28 Vdc output model 54 Vdc output model voltage accuracy at 72 V input, full load, 25°C line regulation load regulation temperature coefficient -40° ~ 105°C min typ max units 20,000 8,300 6,700 4,200 3,600 1,000 μF μF μF μF μF μF 1.0 % from low line to high line, full load ±0.2 % full load to no load ±0.2 % ±0.02 %/°C 220 kHz -1.0 switching frequency 180 200 transient recovery time 75 ~ 100% of step load change, di/dt = 0.1A/µs (within 1% Vout nominal) 250 μs transient response deviation 75 ~ 100% of step load change, di/dt = 0.1A/µs (within 1% Vout nominal) ±5 % start up time / input voltage V on/off to 10% Vo_set, remote on 50 ms start up time / on/off control Vin_min to 10% Vo_set, power up 50 ms rise time 10% Vo_set to 90% Vo_set 50 ms adjustability Po ≤ max rated power, Io ≤ Io_max 54 Vdc output model all other models remote sense Po ≤ max rated power, Io ≤ Io_max % of nominal Vo 54 Vdc output model all other models cui.com -20 -20 10 15 % % 10 15 % % Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER date 04/17/2023 │ page 3 of 9 PROTECTIONS parameter conditions/description min typ max units over voltage protection limited voltage, % of nominal output 54 Vdc output model all other models 112 117 117 125 140 140 % % over current protection auto recovery, hiccup 110 150 180 % short circuit protection continuous, auto recovery over temperature protection temperature at the center part of case, non-latching shutdown recovery 110 100 °C °C SAFETY AND COMPLIANCE parameter isolation voltage conditions/description min typ max units input to output, for 1 minute 3,000 4,200 Vac Vdc input to case (base plate), for 1 minute 2,100 3,000 Vac Vdc output to case (base plate), for 1 minute 1,500 2,100 Vac Vdc isolation resistance input to output isolation capacitance input to output 100 MΩ safety approvals certified to 62368: UL/cUL, EN, IEC concucted emissions EN55032 and EN50155 Compliant (with external filter) ESD EN61000-4-2 Level 3: Air ±8kV, Contact ±6kv, perf. Criteria A radiated immunity EN61000-4-3 Level 3: 80~ 1000 MHz, 20V/m, perf. Criteria A EFT/burst EN61000-4-4 Level 3: on power input port, ±2kV, external input capacitor required (EN 50155), perf. Criteria A surge EN61000-4-5 Level 4: Line to Earth, ±4kV, Line to Line ±2kV (EN50155), perf. Criteria A conducted immunity EN61000-4-6 Level 3: 0.15~80MHz, 10V, perf. Criteria A voltage supply interruptions EN50155 Class S3: 20ms interruptions MTBF as per MIL-HDBK-217F, 25°C 5 Vdc output model 12 Vdc output model 15 Vdc output model 24 Vdc output model 28 Vdc output model 54 Vdc output model RoHS yes 1,000 pF 570 690 785 840 800 850 K hours ENVIRONMENTAL parameter conditions/description min max units operating case temperature measured at the center of the case plate, see derating curve -40 105 °C -55 125 °C 95 % storage temperature operating humidity non-condensing cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER date 04/17/2023 │ page 4 of 9 MECHANICAL parameter conditions/description dimensions 57.9 × 36.8 × 12.8 [2.28 x 1.45 x 0.50 inch] min case material plastic, DAP, UL 94V-0 weight units: inch [mm] tolerances: inches: x.xx = ±0.02, x.xxx = ±0.010 ii mm: x.x = ±0.5, x.xx = ±0.25 PIN Out Function 1 +Vin 2 on/off 3 -Vin 4 -Vo 5 Sense- 6 Trim 7 Sense+ 8 +Vo cui.com max units mm 66 MECHANICAL DRAWING PIN typ g Additional Resources: Product Page | CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER 3D Model | PCB Footprint date 04/17/2023 │ page 5 of 9 DERATING CURVES cui.com Additional Resources: Product Page | CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER 3D Model | PCB Footprint date 04/17/2023 │ page 6 of 9 EFFICIENCY CURVES cui.com Additional Resources: Product Page | CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER 3D Model | PCB Footprint date 04/17/2023 │ page 7 of 9 EFFICIENCY CURVES (CONTINUED) cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER | PCB Footprint date 04/17/2023 │ page 8 of 9 EFFICIENCY CURVES (CONTINUED) Efficiency measured at 100% load. At 80% load when Vin is 12 ~ 16V. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PVQ100W-D │ DESCRIPTION: DC-DC CONVERTER date 04/17/2023 │ page 9 of 9 REVISION HISTORY rev. description date 1.0 initial release 11/22/2022 1.01 clear mounting insert option added 12/12/2022 1.02 PN key updated 04/17/2023 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
PVQ100W-O72-S5-D 价格&库存

很抱歉,暂时无法提供与“PVQ100W-O72-S5-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货