Additional Resources:
Product Page
|
3D Model
date
01/18/2023
page
1 of 5
SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
meets Level VI and CoC Tier 2 efficiency
up to 160 W power
universal input (100~240 Vac)
single regulated outputs
over voltage and short circuit protections
meets UL/cUL 62368 & EN 62368
power factor correction
custom designs available
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
SDI160-12-U-P51
12
12.5
150.0
120
VI
SDI160-19-U-P51
19
8.4
159.6
190
VI
SDI160-24-U-P51
24
6.6
158.4
240
VI
SDI160-48-U-P51
48
3.3
158.4
480
VI
SDI160-56-U-P51
56
2.86
160.1
560
VI
Notes:
efficiency
level2
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF multilayer ceramic and 10 μF low ESR electrolytic capacitors.
2. CoC Tier 2 compliant
PART NUMBER KEY
SDI160 - XX - UX- P51- CXX
Reserved for Custom
Configurations
Base Number
DC Plug Type
Output Voltage
AC Inlet Type:
IEC320/C14
Input cable:
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 2 of 5
INPUT
parameter
min
typ
max
units
voltage
conditions/description
90
100~240
264
Vac
frequency
47
50~60
63
Hz
2.2
A
current
inrush current
at 230 Vac, full load, 25°C, cold start
leakage current
power factor
full load
no load power consumption
at 230 Vac
100
A
3.5
mA
0.15
W
max
units
0.9
OUTPUT
parameter
conditions/description
min
regulation
typ
±5
%
PROTECTIONS
parameter
conditions/description
min
over voltage protection
over current protection
short circuit protection
output shut down, auto recovery
typ
max
units
output shut down, latch
150
%
output shut down, auto recovery
150
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
input to frame ground at 10 mA for 1 minute
isolation resistance
input to output at 500 Vdc
input to frame ground at 500 Vdc
safety marks
UL/cUL (North America), CE (Europe), FCC (USA)
safety approvals
62368: UL/cUL, EN
UKCA
EMI/EMC
FCC Part 15 Class B,
EN 55032:2012 +AC:2013 Class B,
AS/NZS CISPR 32:2015 Class B,
EN55024:2010
MTBF
as per Telcordia SR-332, 25°C
RoHS
yes
typ
3,000
1,500
Vac
Vac
10
10
MΩ
MΩ
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
typ
max
units
0
40
°C
-20
80
°C
operating humidity
non-condensing
20
80
%
storage humidity
non-condensing
10
90
%
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 3 of 5
MECHANICAL
parameter
conditions/description
dimensions
175.2 x 74.0 x 42.0
inlet plug
IEC320/C14
min
typ
units
mm
weight
700
MECHANICAL DRAWING
units: mm
tolerance: ±1.0 mm
DC CORD
units: mm
Table 1
MODEL NO.
max
CABLE
CORD LENGTH
SDI160-12-U-P51
UL2464, 16 AWG
1,200 mm ±50
SDI160-19-U-P51
UL2464, 16 AWG
1,500 mm ±50
SDI160-24-U-P51
UL2464, 16 AWG
1,500 mm ±50
SDI160-48-U-P51
UL2464, 18 AWG
1,500 mm ±50
SDI160-56-U-P51
UL2464, 18 AWG
1,500 mm ±50
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 4 of 5
AC CORD
units: mm
cord length
NORTH AMERICA
EUROPE
UNITED KINGDOM
AUSTRALIA
CHINA
SOUTH KOREA
BRAZIL
SOUTH AFRICA
JAPAN
Table 2
AC INPUT
CORD LENGTH
North America
1,830 mm ±30
Europe
1,830 mm ±30
United Kingdom
1,830 mm ±30
Australia
1,830 mm ±30
China
1,830 mm ±30
South Korea
1,830 mm ±50
Brazil
1,830 mm ±30
South Africa
1,830 mm ±50
Japan
1,830 mm ±30
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
09/28/2020
1.01
dc cord drawing update
10/14/2020
1.02
output plug polarity added
01/12/2021
1.03
UKCA added to specification
08/11/2021
1.04
dc cord tolerance updated for 48V model
06/07/2022
1.05
input voltage updated
01/18/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SDI160-48-U-P51”相匹配的价格&库存,您可以联系我们找货
免费人工找货