SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
GaN technology
compact size
200 W power
universal input (90~264 Vac)
single regulated outputs
over voltage, over current, over temperature and short circuit protections
UL/cUL (62368-1), level VI efficiency
power factor correction
custom designs available
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
SDI200G-12-UD
12
16
192
120
VI
SDI200G-18-UD
18
11.1
200
180
VI
SDI200G-19-UD
19
10.5
200
190
VI
SDI200G-19.5-UD
efficiency
level
19.5
10.2
200
190
VI
SDI200G-20-UD
20
10
200
240
VI
SDI200G-24-UD
24
8.3
200
240
VI
SDI200G-48-UD
48
4.2
202
480
VI
SDI200G-56-UD
56
3.6
202
560
VI
Notes:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 μF multilayer ceramic and 47 μF low ESR electrolytic capacitors.
PART NUMBER KEY
SDI200G - XX - UDX - P51 - CXX
Base Number
Output Voltage
AC Inlet Type:
IEC320/C8
Input Cable:
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
cui.com
Reserved for Custom
Configurations
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 2 of 6
INPUT
parameter
min
typ
max
units
voltage
conditions/description
90
100~240
264
Vac
frequency
47
50~60
63
Hz
2.4
A
current
inrush current
at 240 Vac, full load, 25°C, cold start
leakage current
no load power consumption
at 230 Vac & 115
100
A
0.25
mA
0.21
W
max
units
OUTPUT
parameter
conditions/description
min
regulation
typ
±5
%
PROTECTIONS
parameter
conditions/description
max
units
over voltage protection
output shut down and latch
min
typ
180
%
over current protection
output shut down and automatic recovery
180
%
short circuit protection
output shut down and automatic recovery
over temperature protection
output shut down and latch
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output at 10 mA for 1 minute
min
isolation resistance
input to output at 500 Vdc
safety approvals
UL/cUL (62368-1), UKCA
EMI/EMC
FCC Part 15B Class B, CE
MTBF
as per Telcordia SR-332, 25°C
RoHS
2011/65/EU
typ
3,000
Vac
10
MΩ
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
80
°C
operating humidity
non-condensing
20
80
%
storage humidity
non-condensing
10
90
%
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 3 of 6
MECHANICAL
parameter
conditions/description
dimensions
150 x 54 x 33
inlet plug
4 pin din
weight
without ac cord
min
max
units
mm
560
MECHANICAL DRAWING
units: mm
tolerance: ±1.0
mm
Top-View
Front-View
typ
Side-View
Label
Bottom-View
cui.com
g
Additional Resources:
Product Page
CUI Inc │ SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
|
3D Model
date 01/18/2023 │ page 4 of 6
DC CORD
units: mm
Table 1
MODEL NO.
CABLE
CORD LENGTH
SDI200G-12-UD
Black, UL2464, 16 AWG
1,200 mm ±50
SDI200G-18-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-19-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-19.5-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-20-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-24-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-48-UD
Black, UL2464, 16 AWG
1,500 mm ±50
SDI200G-56-UD
Black, UL2464, 18 AWG
1,500 mm ±50
cui.com
Output cable plug pin assignment
Additional Resources:
Product Page
CUI Inc │ SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
AC CORD (US)
units: mm
AC CORD (EU)
units: mm
cui.com
|
3D Model
date 01/18/2023 │ page 5 of 6
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SDI200G-UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/18/2023 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
01/23/2020
1.01
logo update
02/21/2020
1.02
UL mark added, tolerance updated
01/08/2021
1.03
dc cord table updated
05/06/2021
1.04
UKCA added to the specification
05/25/2021
1.05
dc cord updated
06/15/2021
1.06
input voltage updated
01/18/2023
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SDI200G-48-UD-P51”相匹配的价格&库存,您可以联系我们找货
免费人工找货