0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SDI30-19-U2-P5

SDI30-19-U2-P5

  • 厂商:

    CUI

  • 封装:

    -

  • 描述:

    AC/DCDESKTOPADAPTER19V30W

  • 数据手册
  • 价格&库存
SDI30-19-U2-P5 数据手册
Additional Resources: Product Page date 12/09/2020 page 1 of 6 SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • up to 30 W continuous power DoE Level VI, CoC Tier 2 efficiency universal input voltage range compact size no load power consumption < 0.075 W over voltage and short circuit protections UL/cUL and PSE safety approvals custom designs available MODEL output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) SDI30-12-U 12 2.5 30 200 VI SDI30-15-U 15 2 30 200 VI SDI30-19-U 19 1.6 30 300 VI SDI30-24-U 24 1.25 30 300 VI Notes: efficiency level2 1. Measured at 100~240 Vac input, full load, 20 MHz bandwidth oscilloscope, output terminated with a 10 µF aluminum electrolytic and 0.1 µF ceramic capacitor. 2. CoC Tier 2 compliant PART NUMBER KEY SDI30 - XX - U X - XXX - CXX Base Number Output Voltage AC Inlet Type: IEC320/C14 Input Cable: “Blank” = No Cable C = North America input cable 2 = Europe input cable 3 = United Kingdom input cable 4 = Australia input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.com Reserved for Custom Configurations DC Plug Type: XXX = See output plug options on page 5 for more details Additional Resources: Product Page CUI Inc │ SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY date 12/09/2020 │ page 2 of 6 INPUT parameter max units voltage conditions/description min 90 typ 264 Vac frequency 47 63 Hz 1 A current leakage current no load power consumption 3.5 mA 0.075 W max units OUTPUT parameter conditions/description min load regulation typ ±5 % PROTECTIONS parameter conditions/description min over voltage protection 12 15 19 24 Vdc Vdc Vdc Vdc output output output output over current protection 12 15 19 24 Vdc Vdc Vdc Vdc output output output output short circuit protection output shut down, auto recovery typ max units model model model model 16 22 27 32 Vdc Vdc Vdc Vdc model model model model 4 4 4 2.8 A A A A max units SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output at 10 mA for 1 minute isolation resistance input to output at 500 Vdc safety approvals UL/cUL, PSE EMI/EMC FCC Part 15B Class B RoHS 2011/65/EU typ 1,500 2,121 Vac Vdc 100 MΩ ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature max units 0 typ 40 °C -10 70 °C operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 % cui.com Additional Resources: Product Page CUI Inc │ SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY date 12/09/2020 │ page 3 of 6 MECHANICAL parameter conditions/description dimensions 111 x 52 x 32.3 inlet plug IEC320/C14 weight without AC cord with AC cord min typ 240 270 52 ±1 111 ±1 32.30 ±1 LED Note: 1. LED indicator is not present on 24 Vdc output model. DC CORD units: mm units mm MECHANICAL DRAWING units: mm max ŤŰųťġŭŦůŨŵũ ĶıƲIJı ŇŦųųŪŵŦġŤŰųŦġŸŪŵũġŰůŦġŵŶųůŴġŸŪųŦ IJĵįijřijĹįĶřĹįijĩııĵĪ Table 1 MODEL NO. CABLE CORD LENGTH SDI30-12-U UL2468, 16 AWG 1,530 mm ±100 SDI30-15-U UL2468, 18 AWG 1,530 mm ±100 SDI30-19-U UL2468, 20 AWG 1,530 mm ±100 SDI30-24-U UL2468, 20 AWG 1,530 mm ±100 cui.com g g Additional Resources: Product Page CUI Inc │ SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY date 12/09/2020 │ page 4 of 6 AC CORD units: mm cord length NORTH AMERICA EUROPE UNITED KINGDOM AUSTRALIA CHINA SOUTH KOREA BRAZIL SOUTH AFRICA JAPAN Table 2 AC INPUT CORD LENGTH North America 1,830 mm +200/-30 Europe 1,830 mm +200/-30 United Kingdom 1,830 mm +200/-30 Australia 1,830 mm +200/-30 China 1,830 mm +200/-30 South Korea 1,830 mm ±30 Brazil 1,830 mm ±30 South Africa 1,830 mm ±30 Japan 1,830 mm ±30 cui.com Additional Resources: Product Page CUI Inc │ SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY date 12/09/2020 │ page 5 of 6 DC PLUG TYPE PART NUMBER KEY XXX Plug Polarity: P = Center Positive Plug Code: X = Choose a code from the options below Plug Angle: “blank” = Straight R = Right Angle N = Center Negative Plug Polarity Code Dimensions (mm) Plug Angle Center Pos. Center Neg. Option Type A B C Straight Right ● ● 5 Standard 5.5 2.1 9.5 ● ● ● ● 6 Standard 5.5 2.5 9.5 ● ● ● ● 7 Standard 3.5 1.35 9.5 ● ● ● ● 8 Standard 3.8 1.35 9.5 ● ● ● ● 9 Standard 3.8 1.05 9.5 ● ● ● ● 10 Locking 5.5 2.1 9.5 ● N/A ● ● 11 Locking 5.5 2.5 9.5 ● N/A ● ● 12 EIAJ-1 2.35 0.7 9.5 ● ● ● ● 13 EIAJ-2 4.0 1.7 9.5 ● ● ● ● 14 EIAJ-3 4.75 1.7 9.5 ● ● N/A ST N/A N/A N/A Stripped & Tinned 1. Contact CUI for additional plug options Standard EIAJ Straight C C A A Right Angle (R) C B B A A B C Straight Locking B Note: Right Angle (R) Stripped & Tinned 20±5 9±2 A B C cui.com Additional Resources: Product Page CUI Inc │ SERIES: SDI30-U │ DESCRIPTION: AC-DC POWER SUPPLY date 12/09/2020 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 11/15/2016 1.01 updated datasheet 03/14/2018 1.02 company logo updated 09/30/2020 1.03 safeties updated 12/09/2020 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
SDI30-19-U2-P5 价格&库存

很抱歉,暂时无法提供与“SDI30-19-U2-P5”相匹配的价格&库存,您可以联系我们找货

免费人工找货