Additional Resources:
Product Page
|
3D Model
date
04/26/2021
page
1 of 4
SERIES: SWC27-N │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 27 W power
compact design
DoE Level VI compliant
UL/cUL and PSE safety approvals
universal input voltage range
USB type C inlet
power delivery (PD) 3.0
MODEL
SWC27-T5912-N
Notes:
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
5
9
12
3
3
2.25
15
27
27
200
200
200
efficiency
level2
VI
VI
VI
1. At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF ceramic and 10 µF aluminum electrolytic capacitors.
2. CoC Tier 2 compliant.
PART NUMBER KEY
SWC27 - T5912 - N X - CXX
Reserved for Custom
Configurations
Base Number
Output Voltage
AC Input Type:
North America
cui.com
Case color:
B = black
W = white
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC27-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
max
units
264
Vac
63
Hz
0.7
A
current
at 100 Vac
inrush current
at 240 Vac, cold start, 25°C
100
A
leakage current
at max input voltage, full load
0.25
mA
no load power consumption
at 115/230 Vac
0.075
W
max
units
5.5
9.45
12.6
Vdc
Vdc
Vdc
OUTPUT
parameter
conditions/description
min
voltage accuracy
5 Vdc output
9 Vdc output
12 Vdc output
4.75
8.55
11.4
typ
line regulation
±2
%
load regulation
±5
%
start-up time
hold-up time
3
at 115/230 Vac, 60/50 Hz, full load
5
s
ms
PROTECTIONS
parameter
conditions/description
max
units
over voltage protection
output shut down, auto recovery
min
typ
16
Vdc
over current protection
output shut down, auto recovery
150
%
short circuit protection
output shut down, auto recovery
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output at 3.5 mA for 1 minute
min
insulation resistance
input to output at 500 Vdc for 1 minute
safety approvals
UL/cUL (UL 60950-1), PSE
EMI/EMC
FCC Part 15 Class B, EN 55032 Class B
MTBF
as per MIL-HDBK-217F, full load, 25°C
RoHS
yes
typ
4,242
Vdc
50
MΩ
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
60
°C
operating humidity
non-condensing
10
90
%
storage humidity
non-condensing
5
90
%
5,000
m
altitude
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC27-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
44.2 x 33.2 x 52.5
inlet plug
North America, 2-pin
DC output
USB 3.1 Type C
min
typ
max
units
mm
weight
89
g
MECHANICAL DRAWING
units: mm
PIN CONNECTIONS
PIN
SIGNAL
NAME
PIN
SIGNAL
NAME
A1
GND
B12
GND
A2
NC
B11
NC
A3
NC
B10
NC
A4
VBUS
B9
VBUS
A5
CC1
B8
CC2
A6
D+
B7
D+
A7
D-
B6
D-
A8
NC
B5
NC
A9
VBUS
B4
VBUS
A10
NC
B3
NC
A11
NC
B2
NC
A12
GND
B1
GND
A6(D+)
A7(D-)
A9(+)
A12(-)
B1(-)
B4(+)
cui.com
A5(CC1)
B5(CC2)
A4(+)
A1(-)
B12(-)
B9(+)
B7(D-)
B6(D+)
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC27-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
08/23/2018
1.01
company logo updated
09/30/2020
1.02
safety marks updated
04/26/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SWC27-T5912-NB”相匹配的价格&库存,您可以联系我们找货
免费人工找货