SERIES: SWC45-N │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
up to 45 W continuous power
DoE Level VI compliant
flip Ac pins
universal input voltage range
integrated USB Type C connector
USB Power Delivery (PD) 3.0
UL/cUL safety approvals
Class II construction
MODEL
SWC45-P59121520-N
Notes:
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
5
9
12
15
20
3
3
3
3
2.25
15
27
36
45
45
100
120
150
200
300
efficiency
level2
VI
VI
VI
VI
VI
1. At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF ceramic and 10 µF aluminum electrolytic capacitors.
PART NUMBER KEY
SWC45 - P59121520- N X - X - CXX
Reserved for Custom
Configurations
Base Number
Output Voltage
AC Input Type:
North America
cui.com
Case color:
B = black
W = white
DC cord:
“blank” = no cord
C = with cord
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC45-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at nominal input
leakage current
at nominal AC input and frequency
no load power consumption
at 115/230 Vac, 60/50 Hz (5 Vdc mode)
max
units
264
Vac
63
Hz
1.5
A
0.25
mA
0.1
W
max
units
OUTPUT
parameter
conditions/description
min
output regulation
typ
±5
start-up time
rise time
at nominal input
hold-up time
at nominal input, full load
5
parameter
conditions/description
min
over voltage protection
output shutdown, auto recovery
5 Vdc output
9 Vdc output
12 Vdc output
15 Vdc output
20 Vdc output
over current protection
hiccup, auto recovery
20 Vdc output
all other outputs
short circuit protection
hiccup, auto recovery
%
3
s
100
ms
ms
PROTECTIONS
typ
max
units
8
11.5
15
19
25
Vdc
Vdc
Vdc
Vdc
Vdc
3.2
4
A
A
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
insulation resistance
input to output at 500 Vdc, 10 mA for 1 minute
safety approvals
UL/cUL (UL 60950-1)
EMI/EMC
FCC Part 15 Class B
MTBF
as per Telcordia SR-332, Issue 2 at 115/230 Vac
full load, 25°C
RoHS
yes
typ
3,000
4,242
Vac
Vdc
20
MΩ
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
60
°C
operating humidity
non-condensing
20
85
%
storage humidity
non-condensing
5
90
%
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC45-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
60 x 28 x 57.3
min
inlet plug
North America, 2-pin (flip AC pins)
DC output
USB 3.1 Type C
typ
106
MECHANICAL DRAWING
units: mm
PIN CONNECTIONS
PIN
PIN
SIGNAL
NAME
A1
GND
B12
GND
A2
NC
B11
NC
A3
NC
B10
NC
A4
VBUS
B9
VBUS
A5
CC
B8
NC
A6
D+
B7
NC
A7
D-
B6
NC
A8
NC
B5*
Vconn
A9
VBUS
B4
VBUS
A10
NC
B3
NC
A11
NC
B2
NC
A12
GND
B1
GND
Note: *Not present on DC cord
A1
B12
units
mm
weight
SIGNAL
NAME
max
A12
B1
DC CORD
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWC45-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/26/2021 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
01/17/2019
1.01
company logo updated
09/30/2020
1.02
safety marks updated
04/26/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
SWC45-P59121520-NB-C 价格&库存
很抱歉,暂时无法提供与“SWC45-P59121520-NB-C”相匹配的价格&库存,您可以联系我们找货
免费人工找货