SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
up to 25.2 W continuous power
DoE Level VI and CoC Tier 2 compliant
no load power consumption < 0.075 W
ultra-compact case
universal input voltage range
over voltage, over current, and short circuit protections
CE and GS safety approvals
Class II construction
IEC 62368 compliant
MODEL
input
voltage
input
frequency
output
voltage
output
current
output
power
ripple
and
noise1
range
(Vac)
range
(Hz)
nom
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
average3
(%)
10%
(%)
typ
(W)
SWI25-5-E
90 ~ 264
47 ~ 63
5
4.0
20.0
50
85.4
75.9
0.10
SWI25-12-E
90 ~ 264
47 ~ 63
12
2.1
25.2
120
86.3
77.0
0.10
SWI25-15-E
90 ~ 264
47 ~ 63
15
1.67
25.1
150
86.3
77.0
0.10
SWI25-18-E
90 ~ 264
47 ~ 63
18
1.4
25.2
180
86.3
77.0
0.10
SWI25-24-E
90 ~ 264
47 ~ 63
24
1.05
25.2
240
86.3
77.0
0.10
Notes:
1.
2.
3.
4.
efficiency
level2
no load power
consumption
At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors to ground.
CoC Tier 2 compliant.
Average efficiency is measured at 25%, 50%, 75%, and 100% load.
All specifications are measured at Ta=25°C, nominal input voltage, and 75% rated output load unless otherwise specified.
PART NUMBER KEY
SWI25 - XX - E - P5 - CXX
Reserved for Custom
Configurations
Base Number
Output Voltage
AC Input Type:
Europe
cui.com
DC Plug Type:
5.5 x 2.1 x 9.5 mm
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/27/2020 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
90
frequency
47
typ
current
inrush current
at 240 Vac, 25°C, cold start
leakage current
no load power consumption
max
units
264
Vac
63
Hz
0.7
A
60
A
0.25
mA
0.075
W
max
units
OUTPUT
parameter
conditions/description
min
voltage set point accuracy
at 60% load
±2
%
line regulation
measured from 100~240 Vac, full load
±1
%
load regulation
measured from 60~100% load and 60~20% load
5 Vdc output model
12 Vdc output model
15 Vdc output model
all other models
±6
±5
±3
±2
%
%
%
%
hold-up time
at 115 Vac
10
ms
65
kHz
switching frequency
typ
PROTECTIONS
parameter
conditions/description
over voltage protection
hiccup mode, auto recovery
5 Vdc output model
12 Vdc output model
15 Vdc output model
18 Vdc output model
24 Vdc output model
min
over current protection
hiccup mode, auto recovery
short circuit protection
continuous, hiccup mode, auto recovery
typ
140
max
units
7.44
16.2
18.9
23.5
28.8
Vdc
Vdc
Vdc
Vdc
Vdc
170
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output for 1 minute
isolation resistance
input to output
safety marks
TUV-GS (Germany), CE (EU)
safety approvals
62368: EN, GS TUV
safety class
Class II
EMI/EMC
EN55032
EN55024
MTBF
as per MIL-HDBK-217F at 115 Vac, full load, 25°C
RoHS
2011/65/EU
typ
3,000
4,242
Vac
Vdc
100
MΩ
300,000
hours
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-20
40
°C
storage temperature
-20
85
°C
cui.com
typ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/27/2020 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
71.00 x 33.00 x 48.40 (2.795 x 1.299 x 1.906 inches)
min
inlet plug
Europe
weight
units: mm [inch]
tolerance: X.XX: ±0.50 [±0.020]
DC CORD
cord length
Plug: 5.5 x 2.1 x 9.5 mm
Table 1
MODEL NO.
CABLE
CORD LENGTH
SWI25-5-E
16 AWG
1,220 mm ±50
SWI25-12-E
20 AWG
1,800 mm ±50
SWI25-15-E
20 AWG
1,800 mm ±50
SWI25-18-E
20 AWG
1,800 mm ±50
SWI25-24-E
20 AWG
1,800 mm ±50
cui.com
max
units
mm
140
MECHANICAL DRAWING
units: mm
typ
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/27/2020 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
04/19/2017
1.01
company logo updated
08/24/2020
1.02
updated safeties
10/02/2020
model table updated
11/27/2020
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SWI25-18-E-P5”相匹配的价格&库存,您可以联系我们找货
免费人工找货