0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SWI25-18-E-P5

SWI25-18-E-P5

  • 厂商:

    CUI

  • 封装:

    -

  • 描述:

    AC-DC,18VDC,1.4A,SW,WALL-P

  • 数据手册
  • 价格&库存
SWI25-18-E-P5 数据手册
Additional Resources: Product Page | 3D Model date 11/27/2020 page 1 of 4 SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • • up to 25.2 W continuous power DoE Level VI and CoC Tier 2 compliant no load power consumption < 0.075 W ultra-compact case universal input voltage range over voltage, over current, and short circuit protections CE and GS safety approvals Class II construction IEC 62368 compliant MODEL input voltage input frequency output voltage output current output power ripple and noise1 range (Vac) range (Hz) nom (Vdc) max (A) max (W) max (mVp-p) average3 (%) 10% (%) typ (W) SWI25-5-E 90 ~ 264 47 ~ 63 5 4.0 20.0 50 85.4 75.9 0.10 SWI25-12-E 90 ~ 264 47 ~ 63 12 2.1 25.2 120 86.3 77.0 0.10 SWI25-15-E 90 ~ 264 47 ~ 63 15 1.67 25.1 150 86.3 77.0 0.10 SWI25-18-E 90 ~ 264 47 ~ 63 18 1.4 25.2 180 86.3 77.0 0.10 SWI25-24-E 90 ~ 264 47 ~ 63 24 1.05 25.2 240 86.3 77.0 0.10 Notes: 1. 2. 3. 4. efficiency level2 no load power consumption At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors to ground. CoC Tier 2 compliant. Average efficiency is measured at 25%, 50%, 75%, and 100% load. All specifications are measured at Ta=25°C, nominal input voltage, and 75% rated output load unless otherwise specified. PART NUMBER KEY SWI25 - XX - E - P5 - CXX Reserved for Custom Configurations Base Number Output Voltage AC Input Type: Europe cui.com DC Plug Type: 5.5 x 2.1 x 9.5 mm Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY date 11/27/2020 │ page 2 of 4 INPUT parameter conditions/description min voltage 90 frequency 47 typ current inrush current at 240 Vac, 25°C, cold start leakage current no load power consumption max units 264 Vac 63 Hz 0.7 A 60 A 0.25 mA 0.075 W max units OUTPUT parameter conditions/description min voltage set point accuracy at 60% load ±2 % line regulation measured from 100~240 Vac, full load ±1 % load regulation measured from 60~100% load and 60~20% load 5 Vdc output model 12 Vdc output model 15 Vdc output model all other models ±6 ±5 ±3 ±2 % % % % hold-up time at 115 Vac 10 ms 65 kHz switching frequency typ PROTECTIONS parameter conditions/description over voltage protection hiccup mode, auto recovery 5 Vdc output model 12 Vdc output model 15 Vdc output model 18 Vdc output model 24 Vdc output model min over current protection hiccup mode, auto recovery short circuit protection continuous, hiccup mode, auto recovery typ 140 max units 7.44 16.2 18.9 23.5 28.8 Vdc Vdc Vdc Vdc Vdc 170 % max units SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output for 1 minute isolation resistance input to output safety marks TUV-GS (Germany), CE (EU) safety approvals 62368: EN, GS TUV safety class Class II EMI/EMC EN55032 EN55024 MTBF as per MIL-HDBK-217F at 115 Vac, full load, 25°C RoHS 2011/65/EU typ 3,000 4,242 Vac Vdc 100 MΩ 300,000 hours ENVIRONMENTAL parameter max units operating temperature conditions/description min -20 40 °C storage temperature -20 85 °C cui.com typ Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY date 11/27/2020 │ page 3 of 4 MECHANICAL parameter conditions/description dimensions 71.00 x 33.00 x 48.40 (2.795 x 1.299 x 1.906 inches) min inlet plug Europe weight units: mm [inch] tolerance: X.XX: ±0.50 [±0.020] DC CORD cord length Plug: 5.5 x 2.1 x 9.5 mm Table 1 MODEL NO. CABLE CORD LENGTH SWI25-5-E 16 AWG 1,220 mm ±50 SWI25-12-E 20 AWG 1,800 mm ±50 SWI25-15-E 20 AWG 1,800 mm ±50 SWI25-18-E 20 AWG 1,800 mm ±50 SWI25-24-E 20 AWG 1,800 mm ±50 cui.com max units mm 140 MECHANICAL DRAWING units: mm typ g Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI25-E │ DESCRIPTION: AC-DC POWER SUPPLY date 11/27/2020 │ page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 04/19/2017 1.01 company logo updated 08/24/2020 1.02 updated safeties 10/02/2020 model table updated 11/27/2020 1.03 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
SWI25-18-E-P5 价格&库存

很抱歉,暂时无法提供与“SWI25-18-E-P5”相匹配的价格&库存,您可以联系我们找货

免费人工找货