Additional Resources:
Product Page
|
3D Model
date
04/25/2022
page
1 of 5
SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
up to 3 W continuous power
IEC 62368 compliant
CoC Tier 2 compliant
universal input voltage range
ultra-compact case
no load power consumption < 0.075 W
over voltage, over current, and short circuit protections
CE, GS safety approvals
Class II construction
MODEL
SWI3-5-E
Notes:
input
voltage
input
frequency
output
voltage
output
current
output
power
ripple
and
noise1
efficiency
level2
no load power
consumption
range
(Vac)
range
(Hz)
nom
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
average3
(%)
10%
(%)
typ
(W)
90 ~ 264
47 ~ 63
5
0.6
3
150
74.9
66.2
0.05
1. At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors to ground.
2. CoC Tier 2 compliant.
3. Average efficiency is measured at 25%, 50%, 75%, and 100% load.
PART NUMBER KEY
SWI3 - XX - E - XXX - CXX
Reserved for Custom
Configurations
Base Number
Output Voltage
AC Input Type:
Europe
cui.com
DC Plug Type:
XXX = See output plug options
on page 4 for more details
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/25/2022 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at nominal input voltage
leakage current
at nominal input voltage & frequency
no load power consumption
at 115/230 Vac, 60/50 Hz
max
units
264
Vac
63
Hz
0.2
A
0.25
mA
0.075
W
OUTPUT
parameter
conditions/description
min
line regulation
load regulation
start-up time
max
units
4.9
typ
5.4
Vdc
4.9
5.4
Vdc
3
s
max
units
1
A
max
units
at 115 Vac
PROTECTIONS
parameter
conditions/description
over current protection
auto recovery
min
typ
short circuit protection
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
safety approvals
GS (EN 62368)
EMI/EMC
CE (EN 55032, CISPR 32, EN 61000-3-2, EN
61000-3-3, EN 55024, CISPR 24)
MTBF
as per Telcordia SR-332 (Issue 2), at 115/230 Vac,
full load, 0°C~40°C
RoHS
2011/65/EU
typ
3,000
4,242
Vac
Vdc
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
60
°C
operating humidity
non-condensing
20
85
%
storage humidity
non-condensing
5
95
%
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/25/2022 │ page 3 of 5
MECHANICAL
parameter
conditions/description
dimensions
54.0 x 29.5 x 56.0
inlet plug
Europe
min
typ
max
units
mm
weight
51
MECHANICAL DRAWING
units: mm
DC CORD
units: mm
Table 1
MODEL NO.
CABLE
CORD LENGTH
SWI3-5-E
UL1185, 24 AWG
1,500 mm ±50
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/25/2022 │ page 4 of 5
DC PLUG TYPE PART NUMBER KEY
XXX
Plug Polarity:
P = Center Positive
Plug Code:
X = Choose a code from the
options below
Plug Angle:
“blank” = Straight
R = Right Angle
N = Center Negative
Plug Polarity
Code
Dimensions (mm)
Plug Angle
Center Pos.
Center Neg.
Option
Type
A
B
C
Straight
Right
●
●
5
Standard
5.5
2.1
9.5
●
●
●
●
6
Standard
5.5
2.5
9.5
●
●
●
●
7
Standard
3.5
1.35
9.5
●
●
●
●
8
Standard
3.8
1.35
9.5
●
●
●
●
9
Standard
3.8
1.05
9.5
●
●
●
●
10
Locking2
5.5
2.1
9.5
●
N/A
●
●
11
Locking2
5.5
2.5
9.5
●
N/A
●
●
12
EIAJ-1
2.35
0.7
9.5
●
●
●
●
13
EIAJ-2
4.0
1.7
9.5
●
●
●
●
14
EIAJ-3
4.75
1.7
9.5
●
●
N/A
N/A
ST
N/A
N/A
N/A
MUB
●
N/A
N/A
USB
Micro USB Type B
1. Contact CUI for additional plug options
2. Maximum insertion depth is 10mm
Locking
C
B
A
B
C
Right Angle (R)
C
A
C
Straight
Straight
Right Angle (R)
Stripped & Tinned
USB
5.8±0.5
2.5±0.3
A
B
C
EIAJ
A
A
B
Standard
B
Note:
Stripped & Tinned
P5(-)
cui.com
P1(+)
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/25/2022 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
09/14/2017
1.01
company logo updated
09/21/2020
1.02
logo and model table updated
11/27/2020
1.03
safety line updated
12/09/2020
1.04
plug polarity symbols updated
09/16/2021
1.05
dc plugs updated
04/25/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SWI3-5-E-MUB”相匹配的价格&库存,您可以联系我们找货
免费人工找货