Additional Resources:
Product Page
|
3D Model
date
07/11/2022
page
1 of 4
SERIES: SWI60C-N │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
up to 60 W continuous power
meets DoE Level VI efficiency
universal input voltage range
no load power consumption < 0.21 W
over voltage, over current and short circuit protections
UL 62368 certified
PD 3.0 compliant
custom designs available
MODEL
SWI60C-V-N
Notes:
output
voltage
output
current
output
power
ripple
and noise1
efficiency
level2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
min
(%)
5
3
15
150
81.39
9
3
27
150
86.62
12
3
36
150
87.40
15
3
45
150
87.73
20
3
60
200
88.0
1. At full load, 25°C, at 115/230 Vac input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors.
2. Average efficiency measured at 25%, 50%, 75%, and 100% load at 115/230 Vac.
PART NUMBER KEY
SWI60C - V - NX - X - I40 - CXX
Reserved for Custom
Configurations
Base Number
AC Input Type:
North America
Case color:
W = White
B = Black
cui.com
DC cord:
“blank” = no cord
C = Type C
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI60C-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/11/2022 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
90
frequency
47
typ
current
max
units
264
Vac
63
Hz
1.5
A
inrush current
at 240 Vac, 25°C
100
A
leakage current
at 240 Vac
0.25
mA
0.21
W
max
units
no load power consumption
OUTPUT
parameter
conditions/description
min
typ
line regulation
±2
%
load regulation
±5
%
start-up time
at 100 Vac, full load
3
s
rise time
at 115 Vac, full load
40
ms
hold-up time
at 115 Vac, full load
5
ms
PROTECTIONS
parameter
conditions/description
min
over current protection
auto recovery
3.3
short circuit protection
auto recovery
typ
max
units
4
A
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output for 5 seconds, 5 mA max
safety approvals
62368: ETL
EMI/EMC
FCC Part 15 Class B
MTBF
as per Telcordia SR-332 at 25°C, nominal input
RoHS
yes
typ
3,000
Vac
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
operating humidity
non-condensing
DC CORD
units: mm
cui.com
typ
max
units
0
25
°C
-40
85
°C
5
95
%
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI60C-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/11/2022 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
65.0 x 65.0 x 28.0
inlet plug
North America, 2-pin
DC output
USB Type C
min
typ
max
units
mm
MECHANICAL DRAWING
units: mm
units: mm
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWI60C-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/11/2022 │ page 4 of 4
REVISION HISTORY
rev.
1.0
description
date
initial release
07/11/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“SWI60C-V-EB-I40”相匹配的价格&库存,您可以联系我们找货
免费人工找货