SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
universal input range (90 ~ 264 Vac)
wide operating temperature range (-40 to +85 C)
ultra-low profile (17 mm)
Class B emissions; no external components required
over temperature, over voltage, over current, and short circuit protections
low no-load power consumption (150 mW)
RoHS
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VBM-70-12
12
5.83
70.0
120
88.0
VBM-70-24
24
2.92
70.0
240
88.5
VBM-70-36
36
1.94
69.8
360
89.0
VBM-70-48
48
1.46
70.0
480
89.5
Notes:
1. Ripple and noise are measured at 20 MHz BW with 10 uF aluminum electrolytic capacitor and 0.1 uF ceramic capacitor on the output.
2. Measured at 230 Vac, full load, and 25°C.
3. All specifications measured at: Ta=25°C, 230 Vac input voltage and 60% rated output load, unless otherwise specified.
PART NUMBER KEY
VBM-70 - XX - X
Base Number
Output Voltage
cui.com
Heatsink
"blank" = No
H = Yes
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/09/2021 │ page 2 of 6
INPUT
parameter
conditions/description
min
voltage
frequency
leakage current
typ
90
47
at 264 Vac
no load power consumption
max
units
264
Vac
63
Hz
3.5
mA
0.15
W
max
units
OUTPUT
parameter
conditions/description
min
typ
line regulation
90~264 Vac, full load
±0.5
%
load regulation
60% ±40% rated load
±1
%
voltage accuracy
25°C, full load
hold-up time
at 115 Vac
±1
switching frequency
%
6
ms
65
kHz
PROTECTIONS
parameter
conditions/description
over current protection
auto recovery, hiccup
over voltage protection
auto recovery
short circuit protection
auto recovery
over temperature protection
auto recovery
min
typ
110
12
24
36
48
Vdc
Vdc
Vdc
Vdc
output
output
output
output
model
model
model
model
max
units
150
%
16
35
50
63
Vdc
Vdc
Vdc
Vdc
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute
input to ground for 1 minute
output to ground for 1 minute
min
typ
safety approvals
certified to 62368: IEC/UL/EN
conducted emissions
EN 55032: 2015+AC: 2016, EN 61204-3: 2000, EN 61000-6-3: 2007+A1: 2011+AC: 2012,
EN 61000-6-4: 2007+A1: 2011, 47 CFR FCC Part 15 Subpart B, Class B
radiated emissions
EN 55032: 2015+AC: 2016, EN 61204-3: 2000, EN 61000-6-3: 2007+A1: 2011+AC: 2012,
EN 61000-6-4: 2007+A1: 2011, 47 CFR FCC Part 15 Subpart B, Class B
harmonic current
EN 61000-3-2: 2014
ESD
IEC 61000-4-2: 2008, Air Discharge: ±8KV, Contact Discharge: ±4KV, perf. Criteria A
radiated immunity
EN 55035:2017, EN 61204-3:2000, EN 61000-6-1:2019, EN 61000-6-2:2019
EFT/Burst
IEC 61000-4-4: 2012, ±1kv, ±2kv, perf. Criteria A
surge
IEC 61000-4-5: 2014+A1: 2017, perf. Criteria A
L-N: ±0.5kv, ±1kv, L/N-E(Earth): ±0.5kv, ±1kv, ±2kv, perf. Criteria A
conducted immunity
EN 55035: 2017, EN 61204-3: 2000, EN 61000-6-1: 2019, EN 61000-6-2: 2019
voltage dips and interruption
IEC 61000-4-11: 2004+A1: 2017, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A
MTBF
as per MIL-HDBK-217F at 25°C
RoHS compliant
yes
3,000
1,800
500
550,000
cui.com
Vac
Vac
Vac
hours
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/09/2021 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
85
°C
-40
85
°C
93
%
storage temperature
humidity
non-condensing
DERATING CURVES
EFFICIENCY CURVES
cui.com
typ
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/09/2021 │ page 4 of 6
MECHANICAL
parameter
conditions/description
dimensions
with heatsink
weight
min
135
260
with heatsink
MECHANICAL DRAWING
units: inch [mm]
tolerance: inches: x.xx = ±0.02, x.xxx = ±0.010
mm: x.x = ±0.5, x.xx = ±0.25
PIN CONNECTIONS
PIN
FUNCTION
1
AC (L)
2
AC (N)
3
+Vo
4
Trim
5
-Vo
typ
2.28 x 2.40 x 0.67 [57.9 x 61.0 x 17.0 mm]
2.39 x 2.28 x 1.46 [60.7 x 58.0 x 37.0 mm]
cui.com
max
units
inches
inches
g
g
Additional Resources:
Product Page
|
CUI Inc │ SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
3D Model
|
PCB Footprint
date 12/09/2021 │ page 5 of 6
MECHANICAL DRAWING (CONTINUED)
HEATSINK VERSION
units: inch [mm]
tolerance: inches: x.xx = ±0.02, x.xxx = ±0.010
mm: x.x = ±0.5, x.xx = ±0.25
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VBM-70 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/09/2021 │ page 6 of 6
REVISION HISTORY
rev.
1.0
description
date
initial release
12/09/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.