SERIES: VGD-35 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
universal input voltage range (85~264 Vac)
provides dual outputs; independently isolated
short circuit, over current and over voltage protections
safety certified: IEC/EN/UL 62368
designed to meet: IEC/EN/UL 60335
class B EMI performance, meets CISPR32 / EN 55032
RoHS
MODEL
output
voltage
output
current
output
power1
ripple
and noise2
efficiency
(Vdc)
min
(A)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VGD-35-D512
5
12
0.4
0.1
4
1
32
80
150
81
VGD-35-D524
5
24
0.22
0.1
2.2
1
35
80
150
83
Note:
1. Maximum total combined power.
2. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
PART NUMBER KEY
VGD-35 - DXXX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGD-35 │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/28/2021 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
input current
115 Vac
230 Vac
inrush current
115 Vac, full load, cold start
230 Vac, full load, cold start
max
units
85
120
typ
264
373
Vac
Vdc
47
63
Hz
0.75
0.5
A
A
30
50
A
A
OUTPUT
parameter
conditions/description
min
line regulation
Vo1, at full load
Vo2, at full load
±0.5
±1.5
%
%
load regulation
Vo1, 10% ~ 100% (balanced load)
Vo2, 10% ~ 100% (balanced load)
±0.5
±5.0
%
%
±0.03
%/°C
5
30
ms
ms
temperature coefficient
hold-up time
115 Vac, full load
230 Vac, full load
adjustability
adjustable with built-in trim pot1
output voltage accuracy
Vo1, full load range
Vo2, full load range
Note:
typ
4.75
max
5.50
±2.0
±8.0
units
Vdc
%
%
1. Adjustment of 5 V output only.
PROTECTIONS
parameter
conditions/description
min
typ
max
units
over voltage protection
output clamped
5.75
6.75
V
overload protection
hiccup mode, automatically recovers
110
220
%
short circuit protection
hiccup, continuous, self-recovery
max
units
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
isolation voltage
output to output
input to output
input to ground
output to ground
min
typ
isolation resistance
input to output at 500 Vdc at 25°C
safety approvals
IEC/EN/UL62368
(designed to meet IEC/EN/UL60335)
safety class
Class I
conducted emissions
CISPR32/ EN55032 Class B
radiated emissions
CISPR32/ EN55032 Class B
ESD
IEC/EN61000-4-2, Contact ±6KV / Air ±8KV, perf. Criteria A
radiated immunity
IEC/EN61000-4-3, 10V/m, perf. Criteria A
EFT/burst
IEC/EN61000-4-4, ±2KV, perf. Criteria A
surge
IEC/EN 61000-4-5, Line to Line ±2KV / Line to Ground±4KV, perf. Criteria A
conducted immunity
IEC/EN61000-4-6, 10 Vrms, perf. Criteria A
500
3,000
2,000
500
cui.com
100
Vdc
Vac
Vac
Vac
MΩ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGD-35 │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/28/2021 │ page 3 of 5
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
min
power-frequency magnetic
fields immunity
EN 61000-4-8
voltage dips & interruptions
IEC/EN61000-4-11, 0%,70%, perf. Criteria B
MTBF
MIL-HDBK-217F at 25°C
RoHS compliant
yes
typ
max
300,000
units
hrs
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-30
70
°C
storage temperature
typ
-40
85
°C
operating humidity
non-condensing
10
95
%
storage humidity
non-condensing
10
95
%
max
units
MECHANICAL
parameter
dimensions
cooling method
conditions/description
min
3.9 x 3.8 x 1.2 (99 x 97 x 30 mm)
inch
free air convection (see derating curve below)
weight
case material
typ
210
Metal (AL1100, SGCC)
DERATING CURVES
EFFICIENCY CURVES
cui.com
g
Additional Resources:
Product Page
CUI Inc │ SERIES: VGD-35 │ DESCRIPTION: AC-DC POWER SUPPLY
units: mm [inches]
tolerance: ±1.0 [±0.039]
wire range: 22-14 AWG
tightening torque: M3, 0.5N.m
PIN CONNECTIONS
Function
1
AC (L)
2
AC (N)
3
4
-Vo2
5
+Vo2
6
-Vo1
7
+Vo1
3D Model
date 04/28/2021 │ page 4 of 5
MECHANICAL DRAWING
Pin
|
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGD-35 │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/28/2021 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
11/08/2019
1.01
company logo updated
12/22/2020
1.02
derating and efficiency curves updated
04/28/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“VGD-35-D524”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 66+169.8262766+21.24864