Additional Resources:
Product Page
|
3D Model
date
06/04/2021
page
1 of 5
SERIES: VGS-100W │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
wide input range (85 ~ 305 VAC)
available with conformal coating or terminal cover options
UL/EN/IEC 62368 certified
designed to meet IEC/EN 61558 and IEC/EN 60335 system requirements
short-circuit, over-current, over-voltage protections
CISPR/EN55032 Class B radiated/conducted emissions
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency²
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
5
18.0
90
100
85.5
VGS-100W-12
12
8.5
102
120
87.0
VGS-100W-15
15
7.0
105
120
87.0
VGS-100W-24
24
4.5
108
150
89.5
VGS-100W-36
36
2.8
100
200
89.5
VGS-100W-48
48
2.3
110
200
90.5
VGS-100W-5
Notes:
1. Ripple & noiswe are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac.
PART NUMBER KEY
VGS-100W-XX-X
Base Number
Output Voltage
cui.com
A - with terminal cover
B - with conformal coating
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/04/2021 │ page 2 of 5
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
85
120
305
431
Vac
Vdc
47
63
Hz
3
1.5
A
A
frequency
current
typ
at 115 Vac
at 230 Vac
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
35
65
leakage current
at 277 Vac
no load power consumption
at 230 Vac, 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc output
at 230 Vac, 36 Vdc, 48 Vdc output
A
A
0.75
mA
0.3
0.5
W
W
max
units
10,000
6,800
3,300
2,200
1,000
470
μF
μF
μF
μF
μF
μF
OUTPUT
parameter
conditions/description
capacitive load
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
line regulation
rated load
±0.5
%
load regulation
0% ~ 100%, 5 Vdc output
0% ~ 100%, other outputs
±1
±0.5
%
%
10
55
ms
ms
65
kHz
±0.03
%/°C
±10
%
±2
±1
%
%
hold-up time
min
at 115 Vac
at 230 Vac
switching frequency
temperature coefficient
adjustability
built in trim pot
initial set point accuracy
5 Vdc output
other outputs
typ
PROTECTIONS
parameter
conditions/description
min
over voltage protection
5 Vdc output, clamp, auto recovery
12 Vdc output, clamp, auto recovery
15 Vdc output, clamp, auto recovery
24 Vdc output, clamp, auto recovery
36 Vdc output, clamp, auto recovery
48 Vdc output, clamp, auto recovery
over current protection
auto recovery
short circuit protection
continuous, hiccup, auto recovery
typ
110
max
units
7.5
19.2
24
38.4
57.6
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
160
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to ground, 1 min.
很抱歉,暂时无法提供与“VGS-100W-12-B”相匹配的价格&库存,您可以联系我们找货
免费人工找货