Additional Resources:
Product Page
|
3D Model
date
06/10/2022
page
1 of 6
SERIES: VGS-150D │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
wide input range (85 ~ 305 VAC)
available with conformal coating or terminal cover options
active Power Factor Correction (PFC)
certified to IEC/EN/UL 62368
designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943
output over voltage, over current, over temperature, short circuit protection
CISPR/EN55032 Class B radiated/conducted emissions
input over voltage category III for fixed installations
300 VAC surge resilience (5 seconds)
MODEL
output
voltage
output
current
output
power
ripple
and noise2
efficiency3
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
(Vdc)
range1
(Vdc)
VGS-150D-12
12
10.2 ~ 13.8
12.5
150.0
100
85.5
VGS-150D-15
15
13.5 ~ 18.0
10.0
150.0
100
86.0
VGS-150D-24
24
21.6 ~ 28.8
6.3
151.2
150
87.0
VGS-150D-48
48
45.6 ~ 55.2
3.2
153.6
250
88.0
Notes:
1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage
and output power do not exceed stated limits.
2. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
3. Measured at 230 Vac
PART NUMBER KEY
VGS-150D - XX - X
Base Number
Output Voltage
cui.com
A - with terminal cover
B - with conformal coating
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-150D │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/10/2022 │ page 2 of 6
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
85
120
305
430
Vac
Vdc
47
63
Hz
frequency
typ
current
at 85 Vac
at 115 Vac
at 230 Vac
2.5
2.0
1.0
A
A
A
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
30
45
A
A
leakage current
at 240 Vac
2
mA
power factor
at 115 Vac, full load
at 230 Vac, full load
0.97
0.91
parameter
conditions/description
min
max
units
capacitive load
12
15
24
48
5,000
5,000
5,000
3,000
μF
μF
μF
μF
initial set point accuracy
at full load
12 & 15 Vdc output
24 & 48 Vdc output
OUTPUT
Vdc
Vdc
Vdc
Vdc
output
output
output
output
line regulation
load regulation
0%~100% load
hold-up time
at 230 Vac
±2
±1
%
%
±0.5
%
±0.5
%
±0.05
%/°C
16
temperature coefficient
remote on/off (CTRL)
typ
ms
turn on (0 ~ 0.8 Vdc)
turn off (4 ~ 10 Vdc)
PROTECTIONS
parameter
conditions/description
over voltage protection
12
15
24
48
over current protection
constant current, auto-recovery
over temperature protection1
over temperature protection activation
over temperature protection deactivation
short circuit protection
constant current, continuous, auto-recovery
Vdc
Vdc
Vdc
Vdc
output
output
output
output
model,
model,
model,
model,
output
output
output
output
min
shutdown,
shutdown,
shutdown,
shutdown,
Note: 1. Over temperature protection thresholds under full load conditions.
cui.com
latch
latch
latch
latch
105
50
typ
max
units
16.8
24.5
33.6
60.0
Vdc
Vdc
Vdc
Vdc
150
%
85
°C
°C
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-150D │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/10/2022 │ page 3 of 6
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to ground, 1 min,
很抱歉,暂时无法提供与“VGS-150D-24”相匹配的价格&库存,您可以联系我们找货